Surge arrester type 2, consisting of base element with remote indicator contact and protective plug with N-PE
total current spark gap for mounting on NS 35/7.5, housing width: 17.5 mm (1 Div.)
Product Features
■
■
■
■
■
■
Single-channel, DIN-rail mountable protective devices
Consists of base element and plug
Optical, mechanical status indication for the individual arresters
Mechanical coding of all slots
Disconnect device on each individual plug
Base element with/without floating remote indication contact
Key Commercial Data
Packing unit
1 pc
Weight per Piece (excluding packing)
128.7 g
Custom tariff number
85363010
Country of origin
Germany
Technical data
Dimensions
Height
97 mm
Width
17.6 mm
Depth
65.5 mm
Horizontal pitch
1 Div.
Ambient conditions
Degree of protection
IP20 (only when all terminal points are used)
03/31/2016 Page 1 / 6
https://www.phoenixcontact.com/us/products/2817974
Type 2 surge arrester - F-MS 12/FM - 2817974
Technical data
Ambient conditions
Ambient temperature (operation)
-40 °C ... 80 °C
Ambient temperature (storage/transport)
-40 °C ... 80 °C
Altitude
≤ 2000 m (amsl (above mean sea level))
Permissible humidity (operation)
5 % ... 95 %
Shock (operation)
25g (half sinus / 11 ms / 3x ±X, ±Y, ±Z)
Vibration (operation)
5g (10 ... 500 Hz / 2.5 h / X, Y, Z)
General
Standards/specifications
IEC 61643-11 2011
EN 61643-11 2012
IEC test classification
II
T2
EN type
T2
IEC power supply system
TN
TT
Number of ports
One
SPD design
Voltage-switching type
Mode of protection
N-PE
Mounting type
DIN rail: 35 mm
Color
jet black RAL 9005
Housing material
PA 6.6
PBT
Degree of pollution
2
Flammability rating according to UL 94
V-0
Type
DIN rail module, two-section, divisible
Number of positions
1
Surge protection fault message
Optical, remote indicator contact
Protective circuit
Nominal voltage UN
240/415 V AC (TN - only N-PE)
240/415 V AC (TT - only N-PE)
Nominal frequency fN
50 Hz (60 Hz)
Maximum continuous voltage UC
260 V AC
Rated load current IL
80 A
Residual current IPE
≤ 5 µA
Standby power consumption PC
≤ 1.5 mVA
Nominal discharge current In (8/20) µs
20 kA
Maximum discharge current Imax (8/20) µs
40 kA
03/31/2016 Page 2 / 6
https://www.phoenixcontact.com/us/products/2817974
Type 2 surge arrester - F-MS 12/FM - 2817974
Technical data
Protective circuit
Follow current interrupt rating Ifi
100 A (260 V)
Voltage protection level Up
≤ 1.5 kV
Residual voltage Ures
≤ 0.4 kV (at In)
≤ 0.25 kV (at 10 kA)
≤ 0.15 kV (at 5 kA)
≤ 0.1 kV (at 3 kA)
Front of wave sparkover voltage at 6 kV (1.2/50) µs
≤ 1.5 kV
TOV behavior at UT
1200 V AC (200 ms / withstand mode)
Response time tA
≤ 100 ns
Max. backup fuse with V-type through wiring
80 A (gG)
Indicator/remote signaling
Connection name
Remote fault indicator contact
Switching function
PDT contact
Operating voltage
5 V AC ... 250 V AC
30 V DC
Operating current
5 mA AC ... 1 A AC
1 A DC
Connection method
Screw connection
Screw thread
M2
Tightening torque
0.25 Nm
Stripping length
7 mm
Conductor cross section flexible
0.14 mm² ... 1.5 mm²
Conductor cross section solid
0.14 mm² ... 1.5 mm²
Conductor cross section AWG
28 ... 16
Connection data
Connection method
Screw connection
Conductor cross section flexible
1.5 mm² ... 25 mm²
Conductor cross section solid
1.5 mm² ... 35 mm²
Conductor cross section AWG
15 ... 2
Screw thread
M5
Tightening torque
4.5 Nm
Stripping length
16 mm
UL specifications
SPD Type
4CA
Maximum continuous operating voltage MCOV (N-G)
260 V AC
Mode of protection
N-G
03/31/2016 Page 3 / 6
https://www.phoenixcontact.com/us/products/2817974
Type 2 surge arrester - F-MS 12/FM - 2817974
Technical data
UL specifications
Power distribution system
1
Nominal frequency
50/60 Hz
Measured limiting voltage MLV (N-G)
1490 V
Nominal discharge current In (N-G)
20 kA
UL indicator/remote signaling
Operating voltage
125 V AC
Operating current
1 A AC
Tightening torque
4 lbf-in.
Conductor cross section AWG
30 ... 14
UL connection data
Conductor cross section AWG
10 ... 2
Tightening torque
30 lbf-in.
Classifications
eCl@ss
eCl@ss 4.0
27140201
eCl@ss 4.1
27130801
eCl@ss 5.0
27130801
eCl@ss 5.1
27130801
eCl@ss 6.0
27130805
eCl@ss 7.0
27130805
eCl@ss 8.0
27130805
eCl@ss 9.0
27130805
ETIM
ETIM 2.0
EC000941
ETIM 3.0
EC000941
ETIM 4.0
EC000941
ETIM 5.0
EC000941
UNSPSC
UNSPSC 6.01
30212010
UNSPSC 7.0901
39121610
UNSPSC 11
39121610
UNSPSC 12.01
39121610
UNSPSC 13.2
39121620
03/31/2016 Page 4 / 6
https://www.phoenixcontact.com/us/products/2817974
Type 2 surge arrester - F-MS 12/FM - 2817974
Approvals
Approvals
Approvals
IECEE CB Scheme / UL Recognized / KEMA-KEUR / ÖVE / cUL Recognized / GL / CCA / CSA / EAC / EAC / cULus Recognized
Ex Approvals
Approvals submitted
Approval details
IECEE CB Scheme
UL Recognized
KEMA-KEUR
ÖVE
cUL Recognized
GL
CCA
CSA
03/31/2016 Page 5 / 6
https://www.phoenixcontact.com/us/products/2817974
Type 2 surge arrester - F-MS 12/FM - 2817974
Approvals
EAC
EAC
cULus Recognized
Drawings
Dimensional drawing
Circuit diagram
N
99
58
22,5
14
11 FM
51,5
65,5
45
12
Phoenix Contact 2016 © - all rights reserved
http://www.phoenixcontact.com
03/31/2016 Page 6 / 6
很抱歉,暂时无法提供与“F-MS 12/FM”相匹配的价格&库存,您可以联系我们找货
免费人工找货