0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
F-MS 12/FM

F-MS 12/FM

  • 厂商:

    PHOENIX(菲尼克斯)

  • 封装:

  • 描述:

    Surge Suppressors Plug-In 50Hz/60Hz 230VAC

  • 数据手册
  • 价格&库存
F-MS 12/FM 数据手册
https://www.phoenixcontact.com/us/products/2817974 Type 2 surge arrester - F-MS 12/FM - 2817974 Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's documentation. Our General Terms of Use for Downloads are valid (http://phoenixcontact.com/download) Surge arrester type 2, consisting of base element with remote indicator contact and protective plug with N-PE total current spark gap for mounting on NS 35/7.5, housing width: 17.5 mm (1 Div.) Product Features ■ ■ ■ ■ ■ ■ Single-channel, DIN-rail mountable protective devices Consists of base element and plug Optical, mechanical status indication for the individual arresters Mechanical coding of all slots Disconnect device on each individual plug Base element with/without floating remote indication contact Key Commercial Data Packing unit 1 pc Weight per Piece (excluding packing) 128.7 g Custom tariff number 85363010 Country of origin Germany Technical data Dimensions Height 97 mm Width 17.6 mm Depth 65.5 mm Horizontal pitch 1 Div. Ambient conditions Degree of protection IP20 (only when all terminal points are used) 03/31/2016   Page 1 / 6 https://www.phoenixcontact.com/us/products/2817974 Type 2 surge arrester - F-MS 12/FM - 2817974 Technical data Ambient conditions Ambient temperature (operation) -40 °C ... 80 °C Ambient temperature (storage/transport) -40 °C ... 80 °C Altitude ≤ 2000 m (amsl (above mean sea level)) Permissible humidity (operation) 5 % ... 95 % Shock (operation) 25g (half sinus / 11 ms / 3x ±X, ±Y, ±Z) Vibration (operation) 5g (10 ... 500 Hz / 2.5 h / X, Y, Z) General Standards/specifications IEC 61643-11 2011 EN 61643-11 2012 IEC test classification II T2 EN type T2 IEC power supply system TN TT Number of ports One SPD design Voltage-switching type Mode of protection N-PE Mounting type DIN rail: 35 mm Color jet black RAL 9005 Housing material PA 6.6 PBT Degree of pollution 2 Flammability rating according to UL 94 V-0 Type DIN rail module, two-section, divisible Number of positions 1 Surge protection fault message Optical, remote indicator contact Protective circuit Nominal voltage UN 240/415 V AC (TN - only N-PE) 240/415 V AC (TT - only N-PE) Nominal frequency fN 50 Hz (60 Hz) Maximum continuous voltage UC 260 V AC Rated load current IL 80 A Residual current IPE ≤ 5 µA Standby power consumption PC ≤ 1.5 mVA Nominal discharge current In (8/20) µs 20 kA Maximum discharge current Imax (8/20) µs 40 kA 03/31/2016   Page 2 / 6 https://www.phoenixcontact.com/us/products/2817974 Type 2 surge arrester - F-MS 12/FM - 2817974 Technical data Protective circuit Follow current interrupt rating Ifi 100 A (260 V) Voltage protection level Up ≤ 1.5 kV Residual voltage Ures ≤ 0.4 kV (at In) ≤ 0.25 kV (at 10 kA) ≤ 0.15 kV (at 5 kA) ≤ 0.1 kV (at 3 kA) Front of wave sparkover voltage at 6 kV (1.2/50) µs ≤ 1.5 kV TOV behavior at UT 1200 V AC (200 ms / withstand mode) Response time tA ≤ 100 ns Max. backup fuse with V-type through wiring 80 A (gG) Indicator/remote signaling Connection name Remote fault indicator contact Switching function PDT contact Operating voltage 5 V AC ... 250 V AC 30 V DC Operating current 5 mA AC ... 1 A AC 1 A DC Connection method Screw connection Screw thread M2 Tightening torque 0.25 Nm Stripping length 7 mm Conductor cross section flexible 0.14 mm² ... 1.5 mm² Conductor cross section solid 0.14 mm² ... 1.5 mm² Conductor cross section AWG 28 ... 16 Connection data Connection method Screw connection Conductor cross section flexible 1.5 mm² ... 25 mm² Conductor cross section solid 1.5 mm² ... 35 mm² Conductor cross section AWG 15 ... 2 Screw thread M5 Tightening torque 4.5 Nm Stripping length 16 mm UL specifications SPD Type 4CA Maximum continuous operating voltage MCOV (N-G) 260 V AC Mode of protection N-G 03/31/2016   Page 3 / 6 https://www.phoenixcontact.com/us/products/2817974 Type 2 surge arrester - F-MS 12/FM - 2817974 Technical data UL specifications Power distribution system 1 Nominal frequency 50/60 Hz Measured limiting voltage MLV (N-G) 1490 V Nominal discharge current In (N-G) 20 kA UL indicator/remote signaling Operating voltage 125 V AC Operating current 1 A AC Tightening torque 4 lbf-in. Conductor cross section AWG 30 ... 14 UL connection data Conductor cross section AWG 10 ... 2 Tightening torque 30 lbf-in. Classifications eCl@ss eCl@ss 4.0 27140201 eCl@ss 4.1 27130801 eCl@ss 5.0 27130801 eCl@ss 5.1 27130801 eCl@ss 6.0 27130805 eCl@ss 7.0 27130805 eCl@ss 8.0 27130805 eCl@ss 9.0 27130805 ETIM ETIM 2.0 EC000941 ETIM 3.0 EC000941 ETIM 4.0 EC000941 ETIM 5.0 EC000941 UNSPSC UNSPSC 6.01 30212010 UNSPSC 7.0901 39121610 UNSPSC 11 39121610 UNSPSC 12.01 39121610 UNSPSC 13.2 39121620 03/31/2016   Page 4 / 6 https://www.phoenixcontact.com/us/products/2817974 Type 2 surge arrester - F-MS 12/FM - 2817974 Approvals Approvals Approvals IECEE CB Scheme / UL Recognized / KEMA-KEUR / ÖVE / cUL Recognized / GL / CCA / CSA / EAC / EAC / cULus Recognized Ex Approvals Approvals submitted Approval details IECEE CB Scheme  UL Recognized  KEMA-KEUR  ÖVE  cUL Recognized  GL  CCA  CSA  03/31/2016   Page 5 / 6 https://www.phoenixcontact.com/us/products/2817974 Type 2 surge arrester - F-MS 12/FM - 2817974 Approvals EAC  EAC  cULus Recognized  Drawings Dimensional drawing Circuit diagram N 99 58 22,5 14 11 FM 51,5 65,5 45 12 Phoenix Contact 2016 © - all rights reserved http://www.phoenixcontact.com 03/31/2016   Page 6 / 6
F-MS 12/FM 价格&库存

很抱歉,暂时无法提供与“F-MS 12/FM”相匹配的价格&库存,您可以联系我们找货

免费人工找货