0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
MCR-F-UI-DC

MCR-F-UI-DC

  • 厂商:

    PHOENIX(菲尼克斯)

  • 封装:

  • 描述:

    Universal Frequency Transducer

  • 数据手册
  • 价格&库存
MCR-F-UI-DC 数据手册
https://www.phoenixcontact.com/gb/products/2814605 Frequency transducer - MCR-F-UI-DC - 2814605 Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's documentation. Our General Terms of Use for Downloads are valid (http://phoenixcontact.com/download) MCR frequency measuring transducer, programmable, for converting frequencies into analog signals, with 3way isolation and configurable output Why buy this product  Can be programmed via membrane keypad or software  Display of the input or output signal  3-way isolation  Analog and switching output  For NAMUR sensors, floating contacts, frequency generators, and NPN/PNP transistor outputs  Frequencies up to 120 kHz Key Commercial Data Packing unit 1 STK GTIN GTIN 4017918168827 Weight per Piece (excluding packing) 234.900 g Custom tariff number 85437090 Country of origin Germany Technical data Note Utilization restriction EMC: class A product, see manufacturer's declaration in the download area Dimensions Width 45 mm Height 75 mm Depth 110 mm Ambient conditions 01/06/2017   Page 1 / 7 https://www.phoenixcontact.com/gb/products/2814605 Frequency transducer - MCR-F-UI-DC - 2814605 Technical data Ambient conditions Ambient temperature (operation) -20 °C ... 65 °C (for specified data) Input data Frequency input Frequency input Configurable/programmable Yes Frequency measuring range 0.1 Hz ... 120 kHz Available input sources NPN/PNP transistor outputs NAMUR initiators Floating relay contact (dry contact) Frequency generator Encoder supply voltage approx. 15 V DC Encoder supply current max. 25 mA (constant) Signal level 2 VPP (In case of rectangle 0.1 Hz ... 120 kHz) 2 VPP (In case of sine 8 Hz ... 120 kHz) 13 VPP (In case of sine 1 Hz ... 120 kHz) Max. input amplitude 30 V (incl. DC voltage) Impulse form any Pulse time ≥ 1 µs Measured value resolution > 12 bit A/D conversion time ≤ 32 ms Signal input Current input (isolating amplifier function) Configurable/programmable Yes Current input signal 0 mA ... 20 mA (freely adjustable) Input resistance current input 200 Ω Measured value resolution 14 bit (full-scale) Step response (10-90%) < 25 ms Signal input Voltage input (isolating amplifier function) Configurable/programmable Yes Voltage input signal 0 V ... 10 V (freely adjustable) Input resistance of voltage input 95 kΩ Measured value resolution 14 bit (full-scale) Step response (10-90%) < 25 ms Output data Output name Voltage output Number of outputs 1 Configurable/programmable Yes Voltage output signal 0 V ... 10 V 0 V ... 5 V 10 V ... 0 V 5 V ... 0 V Max. output voltage 12.5 V 01/06/2017   Page 2 / 7 https://www.phoenixcontact.com/gb/products/2814605 Frequency transducer - MCR-F-UI-DC - 2814605 Technical data Output data Load/output load voltage output ≥ 500 Ω Ripple < 20 mVPP Output name Current output Configurable/programmable Yes Current output signal 0 mA ... 20 mA 4 mA ... 20 mA 20 mA ... 0 mA 20 mA ... 4 mA Max. output current 25 mA Load/output load current output ≤ 500 Ω Ripple < 20 mVPP Switching output Output name Transistor output, pnp Output description Switches supply voltage to terminal block SW, can carry a load of 100 mA, not protected against short-circuit Output data Step response (10-90%) < 25 ms Power supply Supply voltage range 20 V DC ... 30 V DC Max. current consumption < 60 mA (without load, without switching output) Connection data Connection method Screw connection Conductor cross section solid min. 0.2 mm² Conductor cross section solid max. 2.5 mm² Conductor cross section AWG min. 24 Conductor cross section AWG max. 14 Conductor cross section flexible min. 0.2 mm² Conductor cross section flexible max. 2.5 mm² Stripping length 8 mm Screw thread M3 General Maximum transmission error ≤ 0.15 % (of measured value) Transmission error, typical 0.1 % Maximum temperature coefficient 0.015 %/K Temperature coefficient, typical 0.01 %/K Alignment zero ± 25 % Alignment span ± 25 % Step response (10-90%) < 25 ms Status display LC display 01/06/2017   Page 3 / 7 https://www.phoenixcontact.com/gb/products/2814605 Frequency transducer - MCR-F-UI-DC - 2814605 Technical data General Operating elements Membrane keypad with 3 keys and LCD display Protective circuit Transient protection Reverse polarity protection Test voltage, input/output/supply 1.5 kV (50 Hz, 1 min.) Color green Housing material ASA-PC (V0) Mounting position any Conformance CE-compliant UL, USA/Canada Class I, Div. 2, Groups A, B, C, D or Non-Hazardous Locations GL Germanischer Lloyd Standards and Regulations Connection in acc. with standard CUL Conformance CE-compliant UL, USA/Canada Class I, Div. 2, Groups A, B, C, D or Non-Hazardous Locations GL Germanischer Lloyd Environmental Product Compliance China RoHS Environmentally Friendly Use Period = 50 For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” Drawings Dimensional drawing 75 Circuit diagram 45 NPN PNP Dry Contact 1 2 +8,2 V 3 4 f in 5 6 NPN PNP +15 V DC DC Namur IN DC GND 1 mC 110 A 0-10 V 7 U in 8 I in 0-20 mA D D D +24 V GND 11 SW 12 GND 13 NC 14 I OUT 15 16 U OUT GND 2 A D A 9 10 A 01/06/2017   Page 4 / 7 https://www.phoenixcontact.com/gb/products/2814605 Frequency transducer - MCR-F-UI-DC - 2814605 Connection diagram 1 2 3 4 NPN PNP Dry Contact 5 6 +8,2 V DC 0-10 V 7 0-20 mA 8 10 GND DC 11 SW GND 1 µC NPN PNP 12 GND 24 V 13 NC +15 V A NAMUR Sensor 9 +24 V DC Namur IN F in U in A A I in 14 I OUT D D Mains voltage 15 U OUT D 16 GND 2 A D Control system Application example: Flow measurement Connection diagram 1 2 3 4 NPN PNP Dry Contact NAMUR sensor ≤1.2 mA actuated: not actuated: ≥2.1 mA 5 6 +8,2 V DC DC Namur IN F in Alarm 11 SW GND 1 µC NPN PNP 12 GND 7 0-20 mA 8 U in 14 I OUT D A D A I in 24 V 13 NC +15 V A 0-10 V 9 +24 V 10 GND DC Mains voltage 15 U OUT D A D 16 GND 2 Control system Application example: Measurement of revolutions of a drive Classifications eCl@ss eCl@ss 4.0 27210120 eCl@ss 4.1 27210120 eCl@ss 5.0 27210120 eCl@ss 5.1 27210120 eCl@ss 6.0 27210120 eCl@ss 7.0 27210120 eCl@ss 8.0 27210120 eCl@ss 9.0 27210120 01/06/2017   Page 5 / 7 https://www.phoenixcontact.com/gb/products/2814605 Frequency transducer - MCR-F-UI-DC - 2814605 Classifications ETIM ETIM 4.0 EC002653 ETIM 5.0 EC002653 ETIM 6.0 EC002653 UNSPSC UNSPSC 6.01 30211506 UNSPSC 7.0901 39121008 UNSPSC 11 39121008 UNSPSC 12.01 39121008 UNSPSC 13.2 39121008 Approvals Approvals Approvals UL Recognized / cUL Recognized / EAC / GL / cULus Recognized Ex Approvals UL Listed / cUL Listed / cULus Listed Approval details UL Recognized    http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm  FILE E 238705 cUL Recognized    http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm  FILE E 238705 EAC      EAC-Zulassung GL    http://www.gl-group.com/newbuilding/approvals/index.html  15882-00 HH 01/06/2017   Page 6 / 7 https://www.phoenixcontact.com/gb/products/2814605 Frequency transducer - MCR-F-UI-DC - 2814605 Approvals cULus Recognized    http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm   Accessories Accessories Arrester test system Cable - CM-KBL-RS232/USB - 2881078 Connecting cable D-9-SUB to USB, with adapter D-9-SUB to D-25-SUB.     Programming adapter Adapter cable - MCR-TTL-RS232-E - 2814388 Software adapter cable (Stereo jack connector/D-SUB 25-pos.), 1.2 m length, for programming MCR-T-..., MCR-S-... and MCR-f-... modules     Phoenix Contact 2017 © - all rights reserved http://www.phoenixcontact.com 01/06/2017   Page 7 / 7
MCR-F-UI-DC 价格&库存

很抱歉,暂时无法提供与“MCR-F-UI-DC”相匹配的价格&库存,您可以联系我们找货

免费人工找货