https://www.phoenixcontact.com/gb/products/2814605
Frequency transducer - MCR-F-UI-DC - 2814605
Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's
documentation. Our General Terms of Use for Downloads are valid
(http://phoenixcontact.com/download)
MCR frequency measuring transducer, programmable, for converting frequencies into analog signals, with 3way isolation and configurable output
Why buy this product
Can be programmed via membrane keypad or software
Display of the input or output signal
3-way isolation
Analog and switching output
For NAMUR sensors, floating contacts, frequency generators, and NPN/PNP transistor outputs
Frequencies up to 120 kHz
Key Commercial Data
Packing unit
1 STK
GTIN
GTIN
4017918168827
Weight per Piece (excluding packing)
234.900 g
Custom tariff number
85437090
Country of origin
Germany
Technical data
Note
Utilization restriction
EMC: class A product, see manufacturer's declaration in the download
area
Dimensions
Width
45 mm
Height
75 mm
Depth
110 mm
Ambient conditions
01/06/2017 Page 1 / 7
https://www.phoenixcontact.com/gb/products/2814605
Frequency transducer - MCR-F-UI-DC - 2814605
Technical data
Ambient conditions
Ambient temperature (operation)
-20 °C ... 65 °C (for specified data)
Input data
Frequency input
Frequency input
Configurable/programmable
Yes
Frequency measuring range
0.1 Hz ... 120 kHz
Available input sources
NPN/PNP transistor outputs
NAMUR initiators
Floating relay contact (dry contact)
Frequency generator
Encoder supply voltage
approx. 15 V DC
Encoder supply current
max. 25 mA (constant)
Signal level
2 VPP (In case of rectangle 0.1 Hz ... 120 kHz)
2 VPP (In case of sine 8 Hz ... 120 kHz)
13 VPP (In case of sine 1 Hz ... 120 kHz)
Max. input amplitude
30 V (incl. DC voltage)
Impulse form
any
Pulse time
≥ 1 µs
Measured value resolution
> 12 bit
A/D conversion time
≤ 32 ms
Signal input
Current input (isolating amplifier function)
Configurable/programmable
Yes
Current input signal
0 mA ... 20 mA (freely adjustable)
Input resistance current input
200 Ω
Measured value resolution
14 bit (full-scale)
Step response (10-90%)
< 25 ms
Signal input
Voltage input (isolating amplifier function)
Configurable/programmable
Yes
Voltage input signal
0 V ... 10 V (freely adjustable)
Input resistance of voltage input
95 kΩ
Measured value resolution
14 bit (full-scale)
Step response (10-90%)
< 25 ms
Output data
Output name
Voltage output
Number of outputs
1
Configurable/programmable
Yes
Voltage output signal
0 V ... 10 V
0 V ... 5 V
10 V ... 0 V
5 V ... 0 V
Max. output voltage
12.5 V
01/06/2017 Page 2 / 7
https://www.phoenixcontact.com/gb/products/2814605
Frequency transducer - MCR-F-UI-DC - 2814605
Technical data
Output data
Load/output load voltage output
≥ 500 Ω
Ripple
< 20 mVPP
Output name
Current output
Configurable/programmable
Yes
Current output signal
0 mA ... 20 mA
4 mA ... 20 mA
20 mA ... 0 mA
20 mA ... 4 mA
Max. output current
25 mA
Load/output load current output
≤ 500 Ω
Ripple
< 20 mVPP
Switching output
Output name
Transistor output, pnp
Output description
Switches supply voltage to terminal block SW, can carry a load of 100
mA, not protected against short-circuit
Output data
Step response (10-90%)
< 25 ms
Power supply
Supply voltage range
20 V DC ... 30 V DC
Max. current consumption
< 60 mA (without load, without switching output)
Connection data
Connection method
Screw connection
Conductor cross section solid min.
0.2 mm²
Conductor cross section solid max.
2.5 mm²
Conductor cross section AWG min.
24
Conductor cross section AWG max.
14
Conductor cross section flexible min.
0.2 mm²
Conductor cross section flexible max.
2.5 mm²
Stripping length
8 mm
Screw thread
M3
General
Maximum transmission error
≤ 0.15 % (of measured value)
Transmission error, typical
0.1 %
Maximum temperature coefficient
0.015 %/K
Temperature coefficient, typical
0.01 %/K
Alignment zero
± 25 %
Alignment span
± 25 %
Step response (10-90%)
< 25 ms
Status display
LC display
01/06/2017 Page 3 / 7
https://www.phoenixcontact.com/gb/products/2814605
Frequency transducer - MCR-F-UI-DC - 2814605
Technical data
General
Operating elements
Membrane keypad with 3 keys and LCD display
Protective circuit
Transient protection
Reverse polarity protection
Test voltage, input/output/supply
1.5 kV (50 Hz, 1 min.)
Color
green
Housing material
ASA-PC (V0)
Mounting position
any
Conformance
CE-compliant
UL, USA/Canada
Class I, Div. 2, Groups A, B, C, D or Non-Hazardous Locations
GL
Germanischer Lloyd
Standards and Regulations
Connection in acc. with standard
CUL
Conformance
CE-compliant
UL, USA/Canada
Class I, Div. 2, Groups A, B, C, D or Non-Hazardous Locations
GL
Germanischer Lloyd
Environmental Product Compliance
China RoHS
Environmentally Friendly Use Period = 50
For details about hazardous substances go to tab “Downloads”,
Category “Manufacturer's declaration”
Drawings
Dimensional drawing
75
Circuit diagram
45
NPN
PNP
Dry
Contact
1
2
+8,2 V
3
4
f in
5
6
NPN
PNP
+15 V
DC
DC
Namur
IN
DC
GND 1
mC
110
A
0-10 V
7
U in
8
I in
0-20 mA
D
D
D
+24 V
GND
11
SW
12
GND
13
NC
14
I OUT
15
16
U OUT
GND 2
A
D
A
9
10
A
01/06/2017 Page 4 / 7
https://www.phoenixcontact.com/gb/products/2814605
Frequency transducer - MCR-F-UI-DC - 2814605
Connection diagram
1
2
3
4
NPN
PNP
Dry
Contact
5
6
+8,2 V
DC
0-10 V
7
0-20 mA
8
10 GND
DC
11 SW
GND 1
µC
NPN
PNP
12 GND
24 V
13 NC
+15 V
A
NAMUR
Sensor
9 +24 V
DC
Namur
IN
F in
U in
A
A
I in
14 I OUT
D
D
Mains voltage
15 U OUT
D
16 GND 2
A
D
Control system
Application example: Flow measurement
Connection diagram
1
2
3
4
NPN
PNP
Dry
Contact
NAMUR sensor
≤1.2 mA
actuated:
not actuated: ≥2.1 mA
5
6
+8,2 V
DC
DC
Namur
IN
F in
Alarm
11 SW
GND 1
µC
NPN
PNP
12 GND
7
0-20 mA
8
U in
14 I OUT
D
A
D
A
I in
24 V
13 NC
+15 V
A
0-10 V
9 +24 V
10 GND
DC
Mains voltage
15 U OUT
D
A
D
16 GND 2
Control system
Application example: Measurement of revolutions of a drive
Classifications
eCl@ss
eCl@ss 4.0
27210120
eCl@ss 4.1
27210120
eCl@ss 5.0
27210120
eCl@ss 5.1
27210120
eCl@ss 6.0
27210120
eCl@ss 7.0
27210120
eCl@ss 8.0
27210120
eCl@ss 9.0
27210120
01/06/2017 Page 5 / 7
https://www.phoenixcontact.com/gb/products/2814605
Frequency transducer - MCR-F-UI-DC - 2814605
Classifications
ETIM
ETIM 4.0
EC002653
ETIM 5.0
EC002653
ETIM 6.0
EC002653
UNSPSC
UNSPSC 6.01
30211506
UNSPSC 7.0901
39121008
UNSPSC 11
39121008
UNSPSC 12.01
39121008
UNSPSC 13.2
39121008
Approvals
Approvals
Approvals
UL Recognized / cUL Recognized / EAC / GL / cULus Recognized
Ex Approvals
UL Listed / cUL Listed / cULus Listed
Approval details
UL Recognized
http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm
FILE E 238705
cUL Recognized
http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm
FILE E 238705
EAC
EAC-Zulassung
GL
http://www.gl-group.com/newbuilding/approvals/index.html
15882-00 HH
01/06/2017 Page 6 / 7
https://www.phoenixcontact.com/gb/products/2814605
Frequency transducer - MCR-F-UI-DC - 2814605
Approvals
cULus Recognized
http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm
Accessories
Accessories
Arrester test system
Cable - CM-KBL-RS232/USB - 2881078
Connecting cable D-9-SUB to USB, with adapter D-9-SUB to D-25-SUB.
Programming adapter
Adapter cable - MCR-TTL-RS232-E - 2814388
Software adapter cable (Stereo jack connector/D-SUB 25-pos.), 1.2 m length, for programming MCR-T-..., MCR-S-...
and MCR-f-... modules
Phoenix Contact 2017 © - all rights reserved
http://www.phoenixcontact.com
01/06/2017 Page 7 / 7
很抱歉,暂时无法提供与“MCR-F-UI-DC”相匹配的价格&库存,您可以联系我们找货