MCR-VAC-UI-O-DC

MCR-VAC-UI-O-DC

  • 厂商:

    PHOENIX(菲尼克斯)

  • 封装:

  • 描述:

    Voltage Transducer 16-Pin

  • 数据手册
  • 价格&库存
MCR-VAC-UI-O-DC 数据手册
https://www.phoenixcontact.com/gb/products/2811103 Voltage measuring transducers - MCR-VAC-UI-O-DC - 2811103 Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's documentation. Our General Terms of Use for Downloads are valid (http://phoenixcontact.com/download) MCR voltage measuring transducer, for alternating current voltages from 0..20 V AC to 0..440 V AC, output signal 0..10 V/0(4)..20 mA Your advantages  Replacement device MACX MCR-VAC-(PT) 2906239 with 8 measurement ranges from 0 V ... 20 V AC to 0 V ... 660 V AC, output signals: 0 V ... 10 V / 0 (4) mA ... 20 mA  Adjustable voltage ranges  Bidirectional output signals  3-way isolation  ZERO/SPAN adjustment ±20%  Tool-free parameterization of measured values  Teach-in configuration of the measured value range Key Commercial Data Packing unit 1 pc GTIN GTIN 4017918125400 Weight per Piece (excluding packing) 204.500 g Custom tariff number 85437090 Country of origin Germany Technical data Note Utilization restriction EMC: class A product, see manufacturer's declaration in the download area Dimensions Width 22.5 mm Height 99 mm Depth 114.5 mm 02/27/2020   Page 1 / 7 https://www.phoenixcontact.com/gb/products/2811103 Voltage measuring transducers - MCR-VAC-UI-O-DC - 2811103 Technical data Ambient conditions Ambient temperature (operation) -25 °C ... 60 °C Ambient temperature (storage/transport) -40 °C ... 85 °C (non-condensing) Maximum altitude < 2000 m Degree of protection IP20 Noise immunity EN 61000-6-2 Input data Input voltage range 0 V ... 370 V AC Input resistance 370 kΩ Input voltage range 0 V ... 250 V AC Input resistance 250 kΩ Input voltage range 0 V ... 170 V AC Input resistance 170 kΩ Input voltage range 0 V ... 120 V AC Input resistance 120 kΩ Input voltage range 0 V ... 80 V AC Input resistance 80 kΩ Input voltage range 0 V ... 54 V AC Input resistance 54 kΩ Input voltage range 0 V ... 36 V AC Input resistance 36 kΩ Input voltage range 0 V ... 24 V AC Input resistance 24 kΩ Nom. voltage 440 V (ungrounded) 250 V (to earth) Output data Output name Voltage output Voltage output signal 0 V ... 10 V Max. output voltage 15 V Load/output load voltage output > 10 kΩ Ripple < 50 mVPP Output name Current output Current output signal 0 mA ... 20 mA 4 mA ... 20 mA Max. output current 30 mA Load/output load current output < 500 Ω Ripple < 50 mVPP Power supply Supply voltage range 18.5 V DC ... 30.2 V DC Max. current consumption < 45 mA 02/27/2020   Page 2 / 7 https://www.phoenixcontact.com/gb/products/2811103 Voltage measuring transducers - MCR-VAC-UI-O-DC - 2811103 Technical data Connection data Connection method Pluggable screw connection Connection technology Screw connection Stripping length 8 mm Screw thread M3 Conductor cross section solid 0.2 mm² ... 2.5 mm² Conductor cross section flexible 0.2 mm² ... 2.5 mm² Conductor cross section AWG 24 ... 14 General Maximum transmission error < 1.5 % (of final value) Temperature coefficient, typical 0.02 %/K (50/60 Hz) Frequency measuring range 45 Hz ... 400 Hz Alignment zero ± 20 % Alignment span ± 20 % Step response (10-90%) 250 ms Overvoltage category III Degree of pollution 2 Rated insulation voltage 300 V DC Test voltage input/output 3.3 kV (50 Hz, 1 min.) Test voltage input/power supply 3.3 kV (50 Hz, 1 min.) Test voltage output/power supply 1 kV (50 Hz, 1 min.) Electromagnetic compatibility Conformance with EMC directive Noise emission EN 61000-6-4 Noise immunity EN 61000-6-2 Color green Housing material Polyamide PA non-reinforced Conformance CE-compliant UL, USA/Canada cULus Standards and Regulations Electromagnetic compatibility Conformance with EMC directive Noise emission EN 61000-6-4 Noise immunity EN 61000-6-2 Connection in acc. with standard CUL Conformance CE-compliant UL, USA/Canada cULus Conformance/approvals Designation CE Identification CE-compliant Designation UL, USA/Canada Identification cULus 02/27/2020   Page 3 / 7 https://www.phoenixcontact.com/gb/products/2811103 Voltage measuring transducers - MCR-VAC-UI-O-DC - 2811103 Technical data Environmental Product Compliance Lead 7439-92-1 China RoHS Environmentally Friendly Use Period = 50 For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” Drawings Application drawing Voltage measurement in case of grounded circuits 02/27/2020   Page 4 / 7 https://www.phoenixcontact.com/gb/products/2811103 Voltage measuring transducers - MCR-VAC-UI-O-DC - 2811103 Dimensional drawing Circuit diagram Classifications eCl@ss eCl@ss 4.0 27271100 eCl@ss 4.1 27200300 02/27/2020   Page 5 / 7 https://www.phoenixcontact.com/gb/products/2811103 Voltage measuring transducers - MCR-VAC-UI-O-DC - 2811103 Classifications eCl@ss eCl@ss 5.0 27200300 eCl@ss 5.1 27200300 eCl@ss 6.0 27210100 eCl@ss 7.0 27210125 eCl@ss 8.0 27210125 eCl@ss 9.0 27210125 ETIM ETIM 4.0 EC002477 ETIM 5.0 EC002477 ETIM 6.0 EC002477 ETIM 7.0 EC002477 UNSPSC UNSPSC 6.01 30211504 UNSPSC 7.0901 39121006 UNSPSC 11 39121006 UNSPSC 12.01 39121006 UNSPSC 13.2 39121006 UNSPSC 18.0 39121008 UNSPSC 19.0 39121008 UNSPSC 20.0 39121008 UNSPSC 21.0 39121008 Approvals Approvals Approvals UL Recognized / cUL Recognized / EAC / cULus Recognized Ex Approvals Approval details UL Recognized    http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm  FILE E 238705 02/27/2020   Page 6 / 7 https://www.phoenixcontact.com/gb/products/2811103 Voltage measuring transducers - MCR-VAC-UI-O-DC - 2811103 Approvals cUL Recognized    http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm EAC      RU*DE.*08.B.01852-19 cULus Recognized        FILE E 238705 Phoenix Contact 2020 © - all rights reserved http://www.phoenixcontact.com 02/27/2020   Page 7 / 7
MCR-VAC-UI-O-DC 价格&库存

很抱歉,暂时无法提供与“MCR-VAC-UI-O-DC”相匹配的价格&库存,您可以联系我们找货

免费人工找货