PT 2XEX(I)-24DC-ST

PT 2XEX(I)-24DC-ST

  • 厂商:

    PHOENIX(菲尼克斯)

  • 封装:

  • 描述:

    Surge Suppressors 325mA 24VDC DIN Rail

  • 数据手册
  • 价格&库存
PT 2XEX(I)-24DC-ST 数据手册
https://www.phoenixcontact.com/gb/products/2838225 Surge protection plug - PT 2XEX(I)-24DC-ST - 2838225 Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's documentation. Our General Terms of Use for Downloads are valid (http://phoenixcontact.com/download) PT protective plug with protective circuit for two 2-wire floating Ex i signal circuits. Nominal voltage: 24 V DC, HART-compatible. Your advantages  Plugs can be checked with CHECKMASTER  Maximum ease of maintenance thanks to the two-piece design  Tailored to the special requirements of intrinsically safe circuits  Base element remains an integral part of the installation  Consistent plug-in signal circuit protection  Impedance-neutral disconnection of plug for test and maintenance purposes Key Commercial Data Packing unit 10 pc GTIN GTIN 4017918182861 Weight per Piece (excluding packing) 21.090 g Custom tariff number 85363010 Country of origin Germany Technical data Dimensions Height 44.8 mm Width 17.5 mm Depth 51.7 mm Horizontal pitch 1 Div. Complete module height 90 mm Complete module width 17.7 mm 02/27/2020   Page 1 / 12 https://www.phoenixcontact.com/gb/products/2838225 Surge protection plug - PT 2XEX(I)-24DC-ST - 2838225 Technical data Dimensions Complete module depth 65.5 mm Ambient conditions Ambient temperature (operation) -40 °C ... 85 °C Ambient temperature (storage/transport) -40 °C ... 85 °C Altitude ≤ 2000 m (amsl (above mean sea level)) Degree of protection IP20 General Housing material PA 6.6 Flammability rating according to UL 94 V-0 Color sky blue RAL 5015 Mounting type on base element Type Male Number of positions 4 Direction of action Line-Line & Line-Signal Ground/Shield & Signal Ground/Shield-Earth Ground Arrester can be tested with CHECKMASTER from software version: From SW rev. 1.00 Protective circuit IEC test classification C1 C2 C3 D1 Nominal voltage UN 24 V DC Maximum continuous voltage UC 30 V DC 21 V AC Rated current 325 mA (40 °C) Operating effective current IC at UC ≤ 5 µA Residual current IPE ≤ 4 µA Nominal discharge current In (8/20) µs (line-line) 10 kA Nominal discharge current In (8/20) µs (line-earth) 10 kA Pulse discharge current Iimp (10/350) µs (line-line) 1 kA Pulse discharge current Iimp (10/350) µs (line-earth) 2 kA (in total) Total discharge current Itotal (8/20) µs 20 kA Total discharge current Itotal (10/350) µs 2 kA Max. discharge current Imax (8/20) µs maximum (line-line) 10 kA Max. discharge current Imax (8/20) µs maximum (line-earth) 20 kA (in total) Nominal pulse current Ian (10/1000) µs (line-line) 30 A Output voltage limitation at 1 kV/µs (line-line) spike ≤ 45 V Output voltage limitation at 1 kV/µs (line-earth) spike ≤ 1 kV Output voltage limitation at 1 kV/µs (line-line) static ≤ 45 V 02/27/2020   Page 2 / 12 https://www.phoenixcontact.com/gb/products/2838225 Surge protection plug - PT 2XEX(I)-24DC-ST - 2838225 Technical data Protective circuit Output voltage limitation at 1 kV/µs (line-earth) static ≤ 1 kV Residual voltage at In (line-line) ≤ 45 V Residual voltage with Ian (10/1000) µs (line-line) ≤ 50 V Voltage protection level Up (line-line) ≤ 45 V (C1 - 0.5 kV / 250 A) ≤ 50 V (C1 - 1 kV/500 A) ≤ 60 V (C2 - 2 kV/1 kA) ≤ 100 V (C2 - 10 kV / 5 kA) ≤ 50 V (C3 - 10 A) ≤ 50 V (C3 - 25 A) ≤ 150 V (D1 - 1 kA) Voltage protection level Up (line-earth) ≤ 1 kV (C1 - 1 kV/500 A) ≤ 1 kV (C2 - 2 kV/1 kA) ≤ 1 kV (C2 - 10 kV / 5 kA) ≤ 1 kV (D1 - 1 kA) Response time tA (line-line) ≤ 1 ns Response time tA (line-earth) ≤ 100 ns Input attenuation aE, sym. typ. 0.5 dB (≤ 900 kHz / 50 Ω) typ. 0.2 dB (≤ 300 kHz / 150 Ω) typ. 0.1 dB (≤ 60 kHz / 600 Ω) Cut-off frequency fg (3 dB), sym. in 50 Ohm system typ. 4.5 MHz Cut-off frequency fg (3 dB), sym. in 150 Ohm system typ. 1.6 MHz Cut-off frequency fg (3 dB), sym. in 600 Ohm system typ. 400 kHz Resistance per path 2.2 Ω ±10 % Surge protection fault message none Max. required back-up fuse 315 mA (T) Impulse durability (line-line) C1 - 0.5 kV / 250 A C1 - 1 kV / 500 A C2 - 2 kV / 1 kA C2 - 10 kV / 5 kA C3 - 10 A C3 - 25 A D1 - 1 kA Impulse durability (line-earth) C1 - 1 kV / 500 A C2 - 2 kV / 1 kA C2 - 10 kV / 5 kA D1 - 1 kA Alternating current carrying capacity (line-earth) 10 A - 1 s Connection data Connection method Screw connection (in connection with the base element) Screw thread M3 02/27/2020   Page 3 / 12 https://www.phoenixcontact.com/gb/products/2838225 Surge protection plug - PT 2XEX(I)-24DC-ST - 2838225 Technical data Connection data Tightening torque 0.5 Nm Stripping length 8 mm Conductor cross section flexible 0.2 mm² ... 2.5 mm² Conductor cross section solid 0.2 mm² ... 4 mm² Conductor cross section AWG 24 ... 12 Standards and Regulations Standards/specifications EN 61643-21 A2:2013 EN 60079-0 2012 EN 60079-11 2012 EN 60079-26 2007 IEC 61643-21 A2:2012 IEC 60079-0 2011 IEC 60079-11 2011 IEC 60079-26 2006 General Maximum inner capacitance Ci 1.3 nF Max. internal inductance Li 1 µH Maximum inner time factor (Ri/Li) ≤ 0.2 µs Max. input current Ii 325 mA (T4 / ≤ 80°C) 325 mA (T5 / ≤ 55 °C) 325 mA (T6 / ≤40 °C) Max. input voltage Ui 30 V DC max. input power Pi 3W Ambient temperature (operation) -40 °C ... 80 °C (T4) -40 °C ... 55 °C (T5) -40 °C ... 40 °C (T6) Conformity / approvals ATEX  II 1G Ex ia IIC T4...T6 Ga  II 1D Ex ia IIIC T135°C...T85°C Da IECEx Ex ia IIC T4...T6 Ga Ex ia IIIC T135 °C...T85 °C Da Environmental Product Compliance REACh SVHC Lead 7439-92-1 China RoHS Environmentally friendly use period: unlimited = EFUP-e No hazardous substances above threshold values Drawings 02/27/2020   Page 4 / 12 https://www.phoenixcontact.com/gb/products/2838225 Surge protection plug - PT 2XEX(I)-24DC-ST - 2838225 Diagram Dimensional drawing The figure shows the complete module consisting of a base element and connector 02/27/2020   Page 5 / 12 https://www.phoenixcontact.com/gb/products/2838225 Surge protection plug - PT 2XEX(I)-24DC-ST - 2838225 Pictogram Circuit diagram 02/27/2020   Page 6 / 12 https://www.phoenixcontact.com/gb/products/2838225 Surge protection plug - PT 2XEX(I)-24DC-ST - 2838225 Application drawing Application drawing 02/27/2020   Page 7 / 12 https://www.phoenixcontact.com/gb/products/2838225 Surge protection plug - PT 2XEX(I)-24DC-ST - 2838225 Application drawing Classifications eCl@ss eCl@ss 4.0 27130800 eCl@ss 4.1 27130800 eCl@ss 5.0 27130800 eCl@ss 5.1 27130800 eCl@ss 6.0 27130800 eCl@ss 7.0 27130807 eCl@ss 8.0 27130807 eCl@ss 9.0 27130807 ETIM ETIM 2.0 EC000943 ETIM 3.0 EC000943 ETIM 4.0 EC000943 ETIM 5.0 EC000943 ETIM 6.0 EC000943 ETIM 7.0 EC000943 02/27/2020   Page 8 / 12 https://www.phoenixcontact.com/gb/products/2838225 Surge protection plug - PT 2XEX(I)-24DC-ST - 2838225 Classifications UNSPSC UNSPSC 6.01 30212010 UNSPSC 7.0901 39121610 UNSPSC 11 39121610 UNSPSC 12.01 39121610 UNSPSC 13.2 39121620 UNSPSC 18.0 39121620 UNSPSC 19.0 39121620 UNSPSC 20.0 39121620 UNSPSC 21.0 39121620 Approvals Approvals Approvals DNV GL / UL Listed / EAC / EAC Ex Approvals IECEx / ATEX / UL Listed / cUL Listed / EAC Ex / cULus Listed Approval details DNV GL    https://approvalfinder.dnvgl.com/  TAE00001N6 UL Listed    http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm  FILE E 138168     Nominal voltage UN 24 V Nominal current IN 0.47 A EAC      EAC-Zulassung EAC      RU CDE.A*30.B01561 02/27/2020   Page 9 / 12 https://www.phoenixcontact.com/gb/products/2838225 Surge protection plug - PT 2XEX(I)-24DC-ST - 2838225 Accessories Accessories Device marking Zack marker strip - ZBN 18:UNBEDRUCKT - 2809128 Zack marker strip, Strip, white, unlabeled, can be labeled with: CMS-P1-PLOTTER, PLOTMARK, mounting type: snap into tall marker groove, for terminal block width: 18 mm, lettering field size: 18 x 5 mm, Number of individual labels: 5     Labeled terminal marker Zack Marker strip, flat - ZBF 5,LGS:FORTL.ZAHLEN - 0808671 Zack Marker strip, flat, Strip, white, labeled, printed horizontally: consecutive numbers 1 ... 10, 11 ... 20, etc. up to 491 ... 500, mounting type: snap into flat marker groove, for terminal block width: 5 mm, lettering field size: 5.15 x 5.15 mm, Number of individual labels: 10     Zack Marker strip, flat - ZBF 5,LGS:GERADE ZAHLEN - 0810821 Zack Marker strip, flat, Strip, white, labeled, printed horizontally: consecutive numbers 2 ... 20, 22 ... 40, etc. up to 82 ... 100, mounting type: snap into flat marker groove, for terminal block width: 5 mm, lettering field size: 5.15 x 5.15 mm, Number of individual labels: 10     Zack Marker strip, flat - ZBF 5,LGS:UNGERADE ZAHLEN - 0810863 Zack Marker strip, flat, Strip, white, labeled, printed horizontally: Odd numbers 1 - 19, 21 - 39, etc. up to 81 - 99, mounting type: snap into flat marker groove, for terminal block width: 5 mm, lettering field size: 5.15 x 5.15 mm, Number of individual labels: 10     Zack Marker strip, flat - ZBF 5,QR:FORTL.ZAHLEN - 0808697 Zack Marker strip, flat, Strip, white, labeled, Printed vertically: consecutive numbers 1 ... 10, 11 ... 20, etc. up to 91 ... 100, mounting type: snap into flat marker groove, for terminal block width: 5 mm, lettering field size: 5.15 x 5.15 mm, Number of individual labels: 10     Marker pen 02/27/2020   Page 10 / 12 https://www.phoenixcontact.com/gb/products/2838225 Surge protection plug - PT 2XEX(I)-24DC-ST - 2838225 Accessories Marker pen - X-PEN 0,35 - 0811228 Marker pen without ink cartridge, for manual labeling of markers, labeling extremely wipe-proof, line thickness 0.35 mm     Terminal marking Zack Marker strip, flat - ZBF 5:UNBEDRUCKT - 0808642 Zack Marker strip, flat, Strip, white, unlabeled, can be labeled with: PLOTMARK, CMS-P1-PLOTTER, mounting type: snap into flat marker groove, for terminal block width: 5 mm, lettering field size: 5.1 x 5.2 mm, Number of individual labels: 10     Zack Marker strip, flat - ZBF 5/WH-100:UNBEDRUCKT - 0808668 Zack Marker strip, flat, Strip, white, unlabeled, can be labeled with: CMS-P1-PLOTTER, PLOTMARK, mounting type: snap into flat marker groove, for terminal block width: 5 mm, lettering field size: 5.15 x 5.15 mm, Number of individual labels: 10     Necessary add-on products Surge protection base element - PT 2XEX(I)-BE - 2839279 Base element for protective plug PT with protective circuit for two 2-core floating EEx ia signal circuits. Mounting on NS 35/7.5 and NS 35/15, housing width: 17.5 mm     Additional products Shield connection - SSA 3-6 - 2839295 Shield fast connection for 3 ... 6 mm cable diameter. Potential connecting cable: 200 mm, 1 mm², color: black     02/27/2020   Page 11 / 12 https://www.phoenixcontact.com/gb/products/2838225 Surge protection plug - PT 2XEX(I)-24DC-ST - 2838225 Accessories Shield connection - SSA 5-10 - 2839512 Shield fast connection for 5 ... 10 mm cable diameter. Potential connecting cable: 200 mm, 1 mm², color: black     Phoenix Contact 2020 © - all rights reserved http://www.phoenixcontact.com 02/27/2020   Page 12 / 12
PT 2XEX(I)-24DC-ST 价格&库存

很抱歉,暂时无法提供与“PT 2XEX(I)-24DC-ST”相匹配的价格&库存,您可以联系我们找货

免费人工找货