PT-IQ-2X2-EX-24DC-UT 数据手册
https://www.phoenixcontact.com/gb/products/2801513
Surge protection device - PT-IQ-2X2-EX-24DC-UT - 2801513
Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's
documentation. Our General Terms of Use for Downloads are valid
(http://phoenixcontact.com/download)
Surge protection, consisting of protective plug and base element, with integrated multi-stage status indicator
on the module for two 2-wire floating Ex-i signal circuits. HART-compatible.
Key Commercial Data
Packing unit
1 pc
GTIN
GTIN
4046356801232
Weight per Piece (excluding packing)
123.000 g
Custom tariff number
85363010
Country of origin
Germany
Technical data
Dimensions
Height
91.1 mm
Width
17.7 mm
Depth
77.5 mm (incl. DIN rail 7.5 mm)
Horizontal pitch
1 Div.
Ambient conditions
Ambient temperature (operation)
-40 °C ... 70 °C
Ambient temperature (storage/transport)
-40 °C ... 85 °C
Altitude
≤ 2000 m (amsl (above mean sea level))
Degree of protection
IP20
General
Housing material
PA 6.6
Flammability rating according to UL 94
V-0
12/30/2019 Page 1 / 9
https://www.phoenixcontact.com/gb/products/2801513
Surge protection device - PT-IQ-2X2-EX-24DC-UT - 2801513
Technical data
General
Color
black
Mounting type
DIN rail: 35 mm
Type
DIN rail module, two-section, divisible
Direction of action
Line-Line & Line-Signal Ground/Shield & optional Signal Ground/ShieldEarth Ground
Protective circuit
IEC test classification
C1
C2
C3
D1
Nominal voltage UN
24 V DC
Maximum continuous voltage UC
30 V DC
21 V AC
Rated current
350 mA
Operating effective current IC at UC
≤ 5 µA (per system)
Residual current IPE
≤ 100 nA (per system)
Nominal discharge current In (8/20) µs (line-line)
10 kA
Nominal discharge current In (8/20) µs (line-earth)
10 kA
Pulse discharge current Iimp (10/350) µs (line-earth)
2 kA
Total discharge current Itotal (8/20) µs
20 kA
Voltage protection level Up (line-line)
≤ 60 V (C1 - 1 kV/500 A)
≤ 110 V (C2 - 10 kV / 5 kA)
≤ 140 V (C2 - 10 kA)
≤ 50 V (C3 - 25 A)
≤ 55 V (C3 - 100 A)
Voltage protection level Up (line-earth)
≤ 1.3 kV (C2 - 10 kV / 5 kA)
≤ 1.5 kV (C2 - 10 kA)
≤ 1.3 kV (C3 - 100 A)
Response time tA (line-line)
≤ 1 ns
Response time tA (line-earth)
≤ 100 ns
Input attenuation aE, sym.
typ. 0.3 dB (≤ 300 kHz / 150 Ω)
Cut-off frequency fg (3 dB), sym. in 150 Ohm system
typ. 1.1 MHz
Capacity (line-earth)
typ. 2 nF
Resistance per path
1.2 Ω ±5 %
Surge protection fault message
Optical, multi-stage
Max. required back-up fuse
350 mA (F)
Impulse durability (line-line)
C1 - 1 kV / 500 A
C2 - 10 kA
C3 - 100 A
Impulse durability (line-earth)
C2 - 10 kA
12/30/2019 Page 2 / 9
https://www.phoenixcontact.com/gb/products/2801513
Surge protection device - PT-IQ-2X2-EX-24DC-UT - 2801513
Technical data
Protective circuit
D1 - 2 kA
Pulse reset time (line-line)
≤ 30 ms
Pulse reset time (line-earth)
≤ 30 ms
Connection data
Connection method
Screw connection
Screw thread
M3
Tightening torque
0.5 Nm
Stripping length
8 mm
Conductor cross section flexible
0.2 mm² ... 2.5 mm²
Conductor cross section solid
0.2 mm² ... 4 mm²
Conductor cross section AWG
24 ... 12
Connection, equipotential bonding
Connection method
DIN rail NS35
Remote indication contact
Switching function
via DIN rail connector
Standards and Regulations
Standards/specifications
EN 61643-21 A2:2013
IEC 61643-21 A2:2012
EN 61000-6-2 2005
EN 61000-6-3 A1:2011
General
Maximum inner capacitance Ci
negligible
Max. internal inductance Li
negligible
Max. input current Ii
350 mA
Max. input voltage Ui
30 V DC
max. input power Pi
1.2 W
Insulation voltage to ground
> 500 V AC
Standards/specifications
EN 60079-0 2012
EN 60079-11 2012
EN 60079-15 2010
IEC 60079-0 2012
IEC 60079-11 2012
IEC 60079-15 2010
Ambient temperature (operation)
-40 °C ... 50 °C (T6)
-40 °C ... 70 °C (T4)
Environmental Product Compliance
REACh SVHC
Lead 7439-92-1
China RoHS
Environmentally Friendly Use Period = 50
12/30/2019 Page 3 / 9
https://www.phoenixcontact.com/gb/products/2801513
Surge protection device - PT-IQ-2X2-EX-24DC-UT - 2801513
Technical data
Environmental Product Compliance
For details about hazardous substances go to tab “Downloads”,
Category “Manufacturer's declaration”
Drawings
Pictogram
Circuit diagram
12/30/2019 Page 4 / 9
https://www.phoenixcontact.com/gb/products/2801513
Surge protection device - PT-IQ-2X2-EX-24DC-UT - 2801513
Classifications
eCl@ss
eCl@ss 4.0
27130800
eCl@ss 4.1
27130800
eCl@ss 5.0
27130800
eCl@ss 5.1
27130800
eCl@ss 6.0
27130800
eCl@ss 7.0
27130807
eCl@ss 8.0
27130807
eCl@ss 9.0
27130807
ETIM
ETIM 3.0
EC000943
ETIM 4.0
EC000943
ETIM 5.0
EC000943
ETIM 6.0
EC000943
ETIM 7.0
EC000943
UNSPSC
UNSPSC 6.01
30212010
UNSPSC 7.0901
39121610
UNSPSC 11
39121610
UNSPSC 12.01
39121610
UNSPSC 13.2
39121620
UNSPSC 18.0
39121620
UNSPSC 19.0
39121620
UNSPSC 20.0
39121620
UNSPSC 21.0
39121620
Approvals
Approvals
Approvals
UL Listed
Ex Approvals
IECEx / ATEX / UL Listed / cUL Listed / EAC Ex / cULus Listed
Approval details
12/30/2019 Page 5 / 9
https://www.phoenixcontact.com/gb/products/2801513
Surge protection device - PT-IQ-2X2-EX-24DC-UT - 2801513
Approvals
UL Listed
http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm
FILE E 138168
Accessories
Accessories
Device marking
Zack marker strip - ZBN 18:UNBEDRUCKT - 2809128
Zack marker strip, Strip, white, unlabeled, can be labeled with: CMS-P1-PLOTTER, PLOTMARK, mounting type:
snap into tall marker groove, for terminal block width: 18 mm, lettering field size: 18 x 5 mm, Number of individual
labels: 5
Labeled terminal marker
Zack Marker strip, flat - ZBF 5,LGS:FORTL.ZAHLEN - 0808671
Zack Marker strip, flat, Strip, white, labeled, printed horizontally: consecutive numbers 1 ... 10, 11 ... 20, etc. up to
491 ... 500, mounting type: snap into flat marker groove, for terminal block width: 5 mm, lettering field size: 5.15 x
5.15 mm, Number of individual labels: 10
Zack Marker strip, flat - ZBF 5,LGS:GERADE ZAHLEN - 0810821
Zack Marker strip, flat, Strip, white, labeled, printed horizontally: consecutive numbers 2 ... 20, 22 ... 40, etc. up to
82 ... 100, mounting type: snap into flat marker groove, for terminal block width: 5 mm, lettering field size: 5.15 x 5.15
mm, Number of individual labels: 10
Zack Marker strip, flat - ZBF 5,LGS:UNGERADE ZAHLEN - 0810863
Zack Marker strip, flat, Strip, white, labeled, printed horizontally: Odd numbers 1 - 19, 21 - 39, etc. up to 81 - 99,
mounting type: snap into flat marker groove, for terminal block width: 5 mm, lettering field size: 5.15 x 5.15 mm,
Number of individual labels: 10
12/30/2019 Page 6 / 9
https://www.phoenixcontact.com/gb/products/2801513
Surge protection device - PT-IQ-2X2-EX-24DC-UT - 2801513
Accessories
Zack Marker strip, flat - ZBF 5,QR:FORTL.ZAHLEN - 0808697
Zack Marker strip, flat, Strip, white, labeled, Printed vertically: consecutive numbers 1 ... 10, 11 ... 20, etc. up to 91 ...
100, mounting type: snap into flat marker groove, for terminal block width: 5 mm, lettering field size: 5.15 x 5.15 mm,
Number of individual labels: 10
Marker pen
Marker pen - X-PEN 0,35 - 0811228
Marker pen without ink cartridge, for manual labeling of markers, labeling extremely wipe-proof, line thickness 0.35
mm
Mounting material
End clamp - E/ME TBUS NS35 GY - 2713780
End clamp, stable construction for DIN rail bus connector
Terminal marking
Zack Marker strip, flat - ZBF 5:UNBEDRUCKT - 0808642
Zack Marker strip, flat, Strip, white, unlabeled, can be labeled with: PLOTMARK, CMS-P1-PLOTTER, mounting type:
snap into flat marker groove, for terminal block width: 5 mm, lettering field size: 5.1 x 5.2 mm, Number of individual
labels: 10
Zack Marker strip, flat - ZBF 5/WH-100:UNBEDRUCKT - 0808668
Zack Marker strip, flat, Strip, white, unlabeled, can be labeled with: CMS-P1-PLOTTER, PLOTMARK, mounting type:
snap into flat marker groove, for terminal block width: 5 mm, lettering field size: 5.15 x 5.15 mm, Number of individual
labels: 10
Necessary add-on products
12/30/2019 Page 7 / 9
https://www.phoenixcontact.com/gb/products/2801513
Surge protection device - PT-IQ-2X2-EX-24DC-UT - 2801513
Accessories
Separating plate - PT-IQ-EX-L-PP - 2905023
Partition plate for NS-35/7,5 DIN rails to ensure a clearance of 50 mm between the controller and surge protection for
PT-IQ-EX systems.
Separating plate - PT-IQ-EX-H-PP - 2905024
Partition plate for NS-35/7,5 isolated DIN rails (DIN rail is isolated using the AB/NS support bracket) to ensure a
clearance of 50 mm between the controller and surge protection for PT-IQ-EX systems.
Supply and remote module - PT-IQ-PTB-UT - 2800768
Module for power supply and multi-stage, floating remote signaling of connected surge protection modules.
Additional products
Shield connection - SSA 3-6 - 2839295
Shield fast connection for 3 ... 6 mm cable diameter. Potential connecting cable: 200 mm, 1 mm², color: black
Shield connection - SSA 5-10 - 2839512
Shield fast connection for 5 ... 10 mm cable diameter. Potential connecting cable: 200 mm, 1 mm², color: black
Spare parts
12/30/2019 Page 8 / 9
https://www.phoenixcontact.com/gb/products/2801513
Surge protection device - PT-IQ-2X2-EX-24DC-UT - 2801513
Accessories
Surge protection plug - PT-IQ-2X2-EX-24DC-P - 2801515
Surge protection plug with integrated multi-stage status indicator on the module for two 2-wire floating Ex-i signal
circuits. Nominal voltage: 24 V DC
Surge protection base element - PT-IQ-5-EX-BE-UT - 2905497
Base element for protective plug PLUGTRAB PT-IQ-2X2-EX
DIN rail bus connectors - PT-IQ-17,5-TBUS-5-2.0 - 2906878
DIN rail connector for PT-IQ system for establishing remote signaling and the power supply when a surge protection
module is snapped on.
Phoenix Contact 2019 © - all rights reserved
http://www.phoenixcontact.com
12/30/2019 Page 9 / 9