0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
110RCM1000-24DMQF

110RCM1000-24DMQF

  • 厂商:

    POWER-ONE

  • 封装:

  • 描述:

    Module DC-DC 110VIN 1-OUT 24V 42A 1000W

  • 数据手册
  • 价格&库存
110RCM1000-24DMQF 数据手册
RCM500/1000 Series 500/1000 W DC-DC Converters The RCM500 and RCM1000 Series converters are reliable power supplies for railway and transportation systems. They are optimized for 72 or 110 V railway batteries. The output delivers 24 V with 500 or 1000 W. The converters are designed for chassis mounting and exhibit a closed housing with cooling openings. Many options are available, such as an output ORing FET for redundant operation, output voltage adjustment, interruption time of 10 ms, shutdown input, and a monitoring relay (change-over contact). FEATURES • • • • • • • 1 ® 1 Optimized for 72 V or 110 V railway batteries Output voltage 24 V Closed housing for chassis mounting Extremely high efficiency and high power density Low inrush current 3 connectors: Input, output, auxiliary (option) Overtemperature, overvoltage, overcurrent, and short-circuit protection • Many options available • Compliant to EN 50155, EN 50121-3-2, AREMA • RoHS-compatible for all 6 substances • Fire and smoke: compliant to EN 45545 and NFPA 130 • 5 year warranty • Safety-approved to the latest edition of IEC/EN 62368-1 and UL/CSA 62368-1 pending Table of Contents Description........................................................................................1 Model Selection.................................................................................2 Functional Description.......................................................................3 Electrical Input Data..........................................................................4 Electrical Output Data.......................................................................6 Description of Options.......................................................................8 Electromagnetic Compatibility (EMC).............................................. 11 Immunity to Environmental Conditions............................................13 Mechanical Data..............................................................................14 Safety and Installation Instructions..................................................15 Accessories.....................................................................................17 belfuse.com/power-solutions BCD.00803_AK 30 November 2023 RCM Series 500 / 1000 W DC-DC Converters MODEL SELECTION Table 1: Standard models Input voltage V [V] Vi cont [V] 1 i min 43.2 66 Output 50.4 77 (72) (110) Vi max [V] 90 137.5 1 110 154 Power Efficiency 2 Model Vo nom [V] Io nom [A] Po nom [W] η typ 24 21 500 96 72RCM500-24 24 42 1000 96 72RCM1000-24 24 21 500 96.4 110RCM500-24 24 42 1000 96.4 110RCM1000-24 Options [%] D, M, Q, F, K Short time; see table 2 for details. Efficiency at TA = 25 °C, Vi nom, Io nom, Vo nom. 1 2 Part Number Description 110 RCM 500  -24  D   M  Q  F  K Operating input voltage Vi cont (continuously): 50.4 – 90 VDC ............................................................72 77 – 137.5 VDC ......................................................... 110 Series..............................................................................RCM Output power: 500 W ......................................................................500 1000 W.....................................................................1000 Nominal output voltage: 24 V............................................................................-24 Auxiliary functions and options: Out OK, output voltage adjust, shutdown 1 ................... D Interruption time............................................................M ORing FET....................................................................Q Fuse built-in....................................................................F Pluggable Connectors .................................................. K 1 Opt. D requires the auxiliary connector. Note: The sequence of options must follow the order above. Note: All models are RoHS-compliant for all six substances. Available combinations of options: 72/110RCMxxx-24 (K) 72/110RCMxxx-24D (K) 72/110RCMxxx-24DF (K) 72/110RCMxxx-24DMQ (K) 72/110RCMxxx-24DMQF (K) Example: 110RCM500-24DMQ: DC-DC converter, input voltage range 77 to 137.5 V continuously, output providing 24 V /21 A, monitoring relay, output vol­tage adjust, shutdown input, active current sharing, interruption time 10 ms, integrated ORing FET, RoHS-compliant for all six sub­stances. Product Marking Type designation, applicable safety approval and recognition marks, CE mark, pin allocation, and product logo. Input voltage range and input current, nominal output voltage and current, degree of protection, batch no., serial no., and data code including production site, version (modification status) and date of production. Asia-Pacific +86 755 298 85888 EMEA +353 61 49 8941 North America +1 866 513 2839 tech.support@psbel.com belfuse.com/power-solutions © 2023 Bel Fuse Inc. BCD.00803_AK 30 November 2023 Page 2 of 17 RCM Series 500 / 1000 W DC-DC Converters FUNCTIONAL DESCRIPTION The input voltage is fed via an efficient input filter and a step-up converter (switching with 2 × 110 kHz) to the high-efficient DC-DC converter operating at a switching frequency of ap­prox­i­mately 90 kHz. The built-in over­voltage limiter protects against input voltage surges. The inrush current is limited by an electronic circuitry. A VDR resistor protects against external surges. If there is no external circuit breaker, the converter can be ordered with built-in fuse (opt. F). This fuse is not accessible. The circuitry to provide the interruption time (opt. M) is located after the input filter together with the reverse polarity protection formed by a FET. The rectification on the secondary side is provided by syn­chronous rectifiers, in order to keep the losses as low as possible. The output voltage control logic is located on the secondary side and controls the FETs of the DC-DC converter via insulated drivers. An auxiliary converter supplies all circuits with a stable bias voltage. An output ORing FET is available (opt. Q) and allows for a redundant power supply system. Opt. D encompasses an additional signal connector to allow for output voltage adjustment, active current sharing, primary shutdown, and an output voltage monitor activating a relay with change-over contact. The converter is mounted onto a base plate which acts as cooling plate. An additional heatsink for natural convection cooling is available as accessory. A thermal protection on the input and output side prevents from overheating. T T Primary control logic Opt. M Fuse (option F) VDR Insulated driver Isolation SD SD0 Vi+ Insulated driver 1 Ci Input filter 2 + R– R R R+ OK1 OK2 Secondary control logic 3 OK0 NTC + Chu Opt. Q Vi– PE Cy JM201e Auxiliary converter Auxiliary connector (only with option D) Vo+ Output filter Vo– Cy ¹ Reverse polarity protection (FET) , only fitted with opt. F or M ² Bipolar suppressor diode with opt. F or M ³ Relay contact shown under normal operating conditions and output voltage under regulation Fig. 1 Block diagram Asia-Pacific +86 755 298 85888 EMEA +353 61 49 8941 North America +1 866 513 2839 tech.support@psbel.com belfuse.com/power-solutions © 2023 Bel Fuse Inc. BCD.00803_AK 30 November 2023 Page 3 of 17 RCM Series 500 / 1000 W DC-DC Converters ELECTRICAL INPUT DATA General conditions: - TA = 25 °C, unless specified. Table 2a: Input data of RCM500 models Model 72RCM500-24 Characteristics 110RCM500-24 Unit Conditions min typ max min typ max Operating input voltage Io = 0 – Io max TA min – TA max 50.4 (72) 90 77 (110) 137.5 Vi 2s for ≤ 2 s without shutdown 43.2 100.8 66 Vi nom Nominal input voltage Vi abs Input voltage limits 3 s without damage Ii Typical input current Vi nom, I o nom 7.3 Pi 0 No-load input power Vi min – Vi max, Io = 0 2.5 4 2.5 4 P i SD Idle input power Vi min – Vi max, VSD = 0 V 2 3 2 3 Ci Input capacitance 1 7 Ri Input resistance 14 Iinr p Peak inrush current tinr d Duration of inrush current Vi Start-up time ton Start-up time after removal of shutdown 154 72 0 108 0 165 4.8 0 → Vi min, P o nom Vi min, P o nom 300 VSD = 0 → 5 V A W 7 µF 14 20 Vi = Vi max, P o nom V 110 mΩ 20 A 0.5 0.5 1000 1000 500 300 ms 500 Table 2b: Input data of RCM1000 models Model 72RCM1000-24 Characteristics 110RCM1000-24 Unit Conditions min typ max min typ max (72) 90 77 (110) 137.5 100.8 66 Vi Operating input voltage Io = 0 – Io max TA min – TA max 50.4 Vi 2s for ≤ 2 s without shutdown 43.2 Vi nom Nominal input voltage Vi abs Input voltage limits 3 s without damage Ii Typical input current Vi nom, I o nom Pi 0 No-load input power Vi min – Vi max, Io = 0 P i SD Idle input power Vi min – Vi max, VSD = 0 V Ci Input capacitance 1 7 7 µF Ri Input resistance 14 14 mΩ Iinr p Peak inrush current tinr d Duration of inrush current Start-up time ton 1 Start-up time after removal of shutdown 72 0 108 VSD = 0 → 5 V 0 165 9.5 A 3 4 3 4 2.5 3 2.5 3 0 → Vi min, P o nom 300 V 110 15 Vi = Vi max, P o nom Vi min, P o nom 154 W 40 40 0.5 0.5 1000 1000 500 300 A ms 500 Not smoothed by the inrush current limiter at start-up (for inrush current calculation) Asia-Pacific +86 755 298 85888 EMEA +353 61 49 8941 North America +1 866 513 2839 tech.support@psbel.com belfuse.com/power-solutions © 2023 Bel Fuse Inc. BCD.00803_AK 30 November 2023 Page 4 of 17 RCM Series 500 / 1000 W DC-DC Converters Input Transient and Reverse Polarity Protection A VDR resistor and a symmetrical input filter form an effective protection against input transients, which typically occur in many installations, but especially in battery-driven mobile applications. If the input voltage has the wrong polarity, the incorporated reverse diode will cause the external input circuit breaker or fuse to trip. With option M or F (incorporated fuse), an active reverse-polarity protection circuit prevents from any damage. Input Under- / Overvoltage Lockout If the input voltage is out of range, an internally generated signal dis­ables the converter to avoid any damage. Efficiency See fig. 2 for efficiency curves of selected models. 72RCM500-24DMQF 72RCM1000-24DMQF Vin = 72 VDC Efficiency [%] Efficiency [%] Vin = 72 VDC 100 98 96 94 92 90 88 86 84 82 10 20 30 40 50 60 70 80 90 100 100 98 96 94 92 90 88 86 84 82 10 20 30 40 Load [%] 30 40 50 60 Efficiency [%] 80 90 80 90 100 Vin = 110 VDC Efficiency [%] 20 70 110RCM1000-24DMQF Vin = 110 VDC 10 60 Load [%] 110RCM500-24DMQF 100 98 96 94 92 90 88 86 84 82 50 70 80 90 100 100 98 96 94 92 90 88 86 84 82 10 20 30 40 Load [%] 50 60 70 100 Load [%} Fig. 2 Typical efficiency versus output load Asia-Pacific +86 755 298 85888 EMEA +353 61 49 8941 North America +1 866 513 2839 tech.support@psbel.com belfuse.com/power-solutions © 2023 Bel Fuse Inc. BCD.00803_AK 30 November 2023 Page 5 of 17 RCM Series 500 / 1000 W DC-DC Converters ELECTRICAL OUTPUT DATA General conditions: - TA = 25 °C, unless TC is specified - R input not connected Table 3: Output data Model 72/110RCM500-24 Characteristics Unit min typ max min typ max Vo Output voltage 1 V i nom, 0.5 Io nom  23.76 24 24.24 23.76 24 24.24 V ow Worst case output voltage Vi min – Vi max TC min – TC max, 0 - Io nom 23.28 24.72 23.28 V o droop Output voltage droop Vo L Overvoltage shutdown Vo P Overvoltage protection 2 Io nom Nominal output current Io L Output current limit vo Output noise 3 vod Conditions 72/110RCM1000-24 - 10 -5 28 6 28.5 Total incl. spikes Voltage deviation 5 td 4 Dynamic load regulation α vo Temperature coefficient of vo (NTC) Recovery time 28.5 30 31.5 42 45 V i nom, Io nom BW = 20 MHz 240 240 480 480 Vi nom , 0.1 ↔ 0.9 Io nom 1000 1000 5 - 0.02 0 - 0.02 V A 23 0 - Io nom, TC min – TC max V mV/A 28 31.5 21 TC min – TC max Switching frequency 30 24.72 mVpp 5 ms 0 %/K If the output voltage is increased above Vo nom through R-input control, the output power should be reduced accordingly, so that Po max and TC max are not exceeded. 2 Breakdown voltage of the incorporated suppressor diode at 1 mA . Exceeding this value might damage the suppressor diode. 3 Measured according to IEC/EN 61204 with a probe described in annex A 4 Recovery time until Vo returns to ±1% of Vo; see fig. 3. 5 No overshoot at switch on. 6 Output overvoltage shutdown by an electronic circuitry, with automatic recovery. 1 Output Voltage Regulation Vo Vod Vo ±1 % td Vod Vo ±1 % td t Io /Io nom 1 0.5 0 ≥ 10 µs ≥ 10 µs 05102c t Fig. 3 Typical dynamic load regulation of output voltage Asia-Pacific +86 755 298 85888 EMEA +353 61 49 8941 North America +1 866 513 2839 tech.support@psbel.com belfuse.com/power-solutions © 2023 Bel Fuse Inc. BCD.00803_AK 30 November 2023 Page 6 of 17 RCM Series 500 / 1000 W DC-DC Converters Output Current Limitation The output is continuously protected against open-circuit (no load) and short-circuit by an electronic current limitation with rectangular characteristic; see fig. 4. Vo Vo nom 0.98 0.5 JM097 0 IoL 1.0 0.5 Io Io nom Fig. 4 Rectangular current limitation Series, Parallel Connection, Redundancy The outputs of several RCM Series converters may be con­nected in series. Note: If the sum of the output voltages is greater than 60 V, it cannot be considered being SELV (Safety Extra Low Voltage) according to the safety standards. but the voltage may exceed the SELV level. The outputs RCM Series converters may be con­nected in parallel. In order to ensures proper current sharing, the load lines should have equal length and section. The output voltage exhibits a slight droop characteristic, which facilitates current sharing. In addition, the output voltage tends to be lowered with increasing temperature. Converters with option D exhibit an additional pin T to provide active current sharing by simply interconnecting all T- pins. For redundant systems, we recommend option Q, which exhibits ORing diodes built by FETs, in order to keep the losses to a minimum. Figure 5 shows a system with 3 parallel-connected converters forming a redundant system. The output voltage is increased by the resistor R ext2 (as an example). The OK signals, connected in series, allow for monitoring all 3 converters. Input SD OK OK2 OK1 OK0 SD SD0 Vi+ Vi– OK2 OK1 OK0 SD SD0 Vi+ 110RCM1000-24DQ 110RCM1000-24DQ JM237 Vo+ T R+ R R– Vo– Vo+ T R+ R R– Vo– Vo+ T R+ R R– Vo– Rext2 Vi– OK2 OK1 OK0 Vi+ SD + Vi– SD0 – 110RCM1000-24DQ Rext2 Rext2 Load Fig. 5 Parallel connection of 3 converters Asia-Pacific +86 755 298 85888 EMEA +353 61 49 8941 North America +1 866 513 2839 tech.support@psbel.com belfuse.com/power-solutions © 2023 Bel Fuse Inc. BCD.00803_AK 30 November 2023 Page 7 of 17 RCM Series 500 / 1000 W DC-DC Converters Thermal Considerations and Protection A temperature protection is incorporated in the primary and secondary control logic each. It generates an internal inhibit signal, which disables the converter in case of over­tem­per­a­ture. The converter automatically recovers, when the temper­a­ture drops below the limit; see fig. 6. The relationship be­tween TA and TC depends heavily upon the conditions of operation and the integration into a system. Caution: The installer must ensure that under all operating con­ditions TC remains within the limits stated in table 7. For installation without external heatsink it is recommended to use forced air or reduced output power. Po [W] 1000 RCM1000 800 600 with heatsink (dotted lines) RCM500 400 convection cooling 200 0 TC max TA [°C] JM252 40 50 60 70 80 90 100 Fig. 6 Typical output power derating versus temperature; vertical mounting position, free convection cooling. LED Indicator Each converter exhibits a green LED “Out OK”, signaling that the output voltage is inside the specified range. DESCRIPTION OF OPTIONS Option D: Output Monitor, Output Adjust, Shutdown Option D consists of several auxiliary functions (R, OK, SD, T) and en­compasses an additional auxiliary connector. Output Voltage Adjust (R) Note: With open R-input, Vo = Vo nom. The converter allows for adjusting the output voltage in the range of 80 to 105% of Vo nom. The adjust is accomplished by an external resistor Rext1 or Rext2, connected to input R; see fig. 7. Depending on the value of the required output voltage, the resistor shall be connected: either: Between the pins R and R– to adjust the output voltage to a value below Vo nom : Vo Rext1 ≈ 4 kΩ • __________ – 15.8 kΩ Vo nom – Vo Note: Rext1 = 0 Ω reduces Vo  to 80%. or: Between the pins R and R+ to adjust the output voltage to a value greater than Vo nom :                    (V – 2.5 V)   o Rext2 ≈ 4 kΩ • __________________ – 682 kΩ                  2.5 V • (Vo /Vo nom – 1) Note: Rext2 = 0 Ω increases Vo  to 105%. Asia-Pacific +86 755 298 85888 EMEA +353 61 49 8941 North America +1 866 513 2839 tech.support@psbel.com belfuse.com/power-solutions © 2023 Bel Fuse Inc. BCD.00803_AK 30 November 2023 Page 8 of 17 RCM Series 500 / 1000 W DC-DC Converters JM191 Vi+ 628 kΩ Bias Vref = 2.5 V + R+ Rext2 4 kΩ R Control logic Rext1 15.8 kΩ R– Vi– Vo– Fig. 7 Output voltage control via R-input Output Voltage Monitor (OK) The output voltage Vo is monitored. When Vo is in range, a relay with a changeover contact connected to the auxiliary connector is activated, and OK0 is connected with OK2. Note: The trigger levels are typ. ±5 % of Vonom (with open R-input). Data of relay contacts: 0.4 A /150 VDC. Primary Shutdown (SD) The output of the converter may be enabled or disabled by a logic signal (e.g. CMOS) applied between the shutdown pin SD and SD0 (= Vi–). If the shutdown function is not re­quired, pin SD can be left open-circuit. Voltage on pin SD: Converter operating: Converter disabled: 12 V to Vi max or open-circuit – 2 to +2 V The output response is shown in Fig. 8a Note: In systems consisting of several converters, this feature may be used to control the activation sequence by logic signals or to enable the power source to start up, before full load is applied. Vo /Vo nom 1 0.1 0 tr tf td on ton SD 1 0 t off t Fig. 8a Typical output response to the SD-signal. Asia-Pacific +86 755 298 85888 EMEA +353 61 49 8941 North America +1 866 513 2839 tech.support@psbel.com belfuse.com/power-solutions © 2023 Bel Fuse Inc. BCD.00803_AK 30 November 2023 Page 9 of 17 RCM Series 500 / 1000 W DC-DC Converters Option M: Interruption Time The interruption time t hu is specified in the railway standard EN 50155:2017 clause 5.1.1.4: Class S2 is 10 ms. It is measured at VB nom (nominal battery voltage) for interruption and short-circuit of the input. After such an event, the system is ready for the next event after 10 s. Fig. 8b shows the output voltage Vo, if option M is fitted. Option M encompasses a backrush pro­tection formed by a FET device. For less critical applications, option M is not required (class S1). Such units have a slightly better efficiency. Vo /Vo nom 1 tr thu td on 0.1 0 ton Vi 0 t Fig. 8b Typical output response to Vi If option M is not fitted, thu = 0 ms. Option Q: ORing FET for Redundant Systems Two parallel connected converters are separated with ORing diodes (built by FETs). If one converter fails, the remaining one still delivers the full power to the loads. If more power is needed, the system may be extended to more parallel converters (n+1 re­ dundancy). Current sharing must be ensured by load lines of equal section and length. In addition, a slight droop characteristic of the outputs and a negative temperature coefficient are helpful as well. To keep the losses as small as possible, the ORing diode is replaced by a FET. Note: In the case of a failing converter, the output voltage is maintained by the redundant converters. However, the failing item should be identified and replaced. We recommend the Out OK function (option D). Option F: Incorporated Fuse The railway standard EN 50155 does not recommend fuses in converters. Consequently, the installer should preview an external fuse or circuit breaker. However, when this is not possible, we offer an in­corporated fuse (option F) with active reverse polarity protection formed by a FET device. The fuse is not accessible and will not trip, unless the converter is really defect. The type of the incorporated fuses is specified in table 4. Such fuses are also recommended for external fuses. Table 4: Recommended external fuses (same as with option F) Converter Specification Ordering number 72RCM500-24 15 A fast acting Littlefuse 0505015.MX52 LEP 110RCM500-24 15 A fast acting Littlefuse 0505015.MX52 LEP 72RCM1000-24 2x 25 A fast acting Littlefuse 0505025.MX52 LEP 110RCM1000-24 25 A fast acting Littlefuse 0505025.MX52 LEP Option K: Pluggable Connectors This option allows the use of preassembled pluggable con­nectors; for details see Accessories. Note: Female connectors must be ordered separately. Current Share Function in Parallel Operation (T) Just interconnect the T-pins of all converters to balance their output currents. Only a single-wire connection is needed. Asia-Pacific +86 755 298 85888 EMEA +353 61 49 8941 North America +1 866 513 2839 tech.support@psbel.com belfuse.com/power-solutions © 2023 Bel Fuse Inc. BCD.00803_AK 30 November 2023 Page 10 of 17 RCM Series 500 / 1000 W DC-DC Converters ELECTROMAGNETIC COMPATIBILITY (EMC) Electromagnetic Immunity Table 5: Electromagnetic immunity (type tests). Corresponds or Exceeds EN50121-3-2:2016 and AREMA. Phenomenon Standard Level Electrostatic discharge (to case) IEC/EN 61000-4-2 4 Electromagnetic field  IEC/EN 61000-4-3 x Coupling mode 1 Value applied contact discharge 6000 Vp air discharge 8000 Vp antenna 20 V/m Waveform 1/50 ns AM 80% / 1 kHz Source imped. Test procedure 330 Ω 150 pF N/A 20 V/m antenna 20 V/m 3 5 V/m IEC/EN 61000-4-4 3 3 Surges IEC/EN 61000-4-5 3 Conducted disturbances IEC/EN 61000-4-6 3 Power frequency magnetic field IEC/EN 61000-4-8 3 capacitive, o/c i/c, +i/–i direct ±2000 Vp i/c ±2000 Vp +i/– i ±1000 Vp i/c, +i/–i ±2000 Vp i, o, signal wires 10 VAC (140 dBµV) Perf. crit. 2 10 pos. & 10 neg. discharges yes A 80 – 800 MHz yes A yes A 60 s positive 60 s negative transients per coupling mode yes A 5 pos. & 5 neg. surges per coupling mode yes 0.15 – 80 MHz yes A 60 s in all 3 axis yes A 800 – 1000 MHz AM 80% / 1 kHz N/A 3 V/m Electrical fast transients/burst In oper. 1400 – 2000 MHz 2000 – 2700 MHz 5100 – 6000 MHz bursts of 5/50 ns; 2.5/5 kHz over 15 ms; burst period: 300 ms 50 Ω 42 Ω 0.5 μF 1.2 / 50 µs 12 Ω 9 μF AM 80% / 1 kHz 150 Ω 300 A/m A B i = input, o = output, c = case A = normal operation, no deviation from specs.; B = normal operation, temporary loss of function or deviation from specs possible 3 Tested value 20 V/m is required by AREMA; 10 V/m is valid for EN50121-3-2 1 2 Asia-Pacific +86 755 298 85888 EMEA +353 61 49 8941 North America +1 866 513 2839 tech.support@psbel.com belfuse.com/power-solutions © 2023 Bel Fuse Inc. BCD.00803_AK 30 November 2023 Page 11 of 17 RCM Series 500 / 1000 W DC-DC Converters Electromagnetic Emissions The conducted emissions (fig. 9) have been tested accord­ing to EN 55011, group 1, class A (similar to EN 55032), much better values than requested by EN 50121-3-2:2016, table 2.1. The limits in fig. 9 apply to quasipeak values, which are always lower then peak values. Radiated emissions have been tested as per EN 55011, group 1, class A, similar to EN 61000-6-4+A1:2011, table 1. The test was executed with horizon­tal and vertical polarization; the worse result is shown in fig. 10. Note: The highest frequency of the internal sources of EUT is less than 108 MHz. Hence, Radiated Measurement was made up to 1 GHz. Non-accredited measurement up to 6 GHz are available on request. dBµV dBµV 110RCM500-24DMQF; Vi = 110 V, Vo = 24 V; Io = 21 A Class A, 25-May-2017 EN 55011 A av 60 80 40 20 20 0.2 0.5 1 2 5 10 20 MHz Fig. 9a 110RCM500 -24: Typ. conducted disturbances at the input (Vi =110 V, Ii nom, resistive load, quasi peak and average). dBµV/m EMC Labatory, 110RCM500-24DMQF; Vi = 110 VDC, Vo = 24 V / 21 A ETS-3143B Testdistance 3 m, Class A, 25-May-2017 60 JM226 EN 55011 A av av 60 40 0 qp EN 55011 A qp 0 0.2 0.2 0.5 0.5 11 22 dBµV/m 60 50 40 40 30 30 20 20 10 10 50 100 200 500 1000 MHz Fig. 10a 110RCM500 -24: Typ. radiated disturbances in 3 m distance (Vi = 110 V, I i nom, resistive load, quasi peak). 10 10 20 20 MHz MHz EMC Labatory, 110RCM500-24DMQF; Vi = 110 VDC, Vo = 24 V / 42 A ETS-3143B Testdistance 3 m, Class A, 25-May-2017 JM228 QP Limit EN 55011, Group 1, Class A, 3 m 50 30 55 Fig. 9b 110RCM1000 -24: Typ. conducted disturbances at the input (Vi =110 V, I i nom, resistive load, quasi peak and average). QP Limit EN 55011, Group 1, Class A, 3 m 0 JM225 JM227 EN 55011 A qp JM225 80 110RCM500-24DMQF; 110RCM1000-24DMQF; ViVi==110 110V,V,Vo Vo==24 24V;V;IoIo==21 42AA Class A, 25-May-2017 0 30 50 100 200 500 1000 MHz Fig. 10b 110RCM1000 -24: Typ. radiated disturbances in 3 m distance (Vi = 110 V, I i nom, resistive load, quasi peak). Radio disturbance and immunity have been tested as per EN 55016-2-3:2017 with meeting EMV-06, Issue 2.0, Appendix E within the range shown in table below. The test was executed on model 110RCM1000-24DMQF with horizontal and vertical polarization. Test results are availble on request. Table 6: EMV-06, Issue 2.0, Appendix E frequency bands and achieved test results. Band Frequences Result Start Stop H 457.4 MHz 458.3 MHz PASS I 467.4 MHz 468.3 MHz PASS GSM-R UL 873 0 MHz 880.0 MHz PASS GSM-R DL 918.0 MHz 925.0 MHz PASS L-AG 419.7 MHz 419.8 MHz PASS L-VDV 429.7 MHz 429.8 MHz PASS Asia-Pacific +86 755 298 85888 EMEA +353 61 49 8941 North America +1 866 513 2839 tech.support@psbel.com belfuse.com/power-solutions © 2023 Bel Fuse Inc. BCD.00803_AK 30 November 2023 Page 12 of 17 RCM Series 500 / 1000 W DC-DC Converters IMMUNITY TO ENVIRONMENTAL CONDITIONS Table 7: Mechanical and climatic stress. Air pressure 700 – 1200 hPa Test method Standard Test Conditions Ad Low temperature start-up test EN 50155:2017, clause 13.4.4 IEC/EN 60068-2-1 Temperature, duration: - 40 °C, 2 h Performance test: +25 °C Dry heat test, cycle A EN 50155:2017, clause 13.4.5 IEC/EN 60068-2-2 Temperature: 70 °C Duration: 6h Cyclic damp heat test EN 50155:2017, clause 13.4.7 IEC/EN 60068-2-30 Temperature: 55 °C and 25 °C Cycles (respiration effect): 2 Duration: 2x 24 h Be Db 2 Ka Not operating Operating perf. crit. A Not operating Salt mist test sodium chloride (NaCl) solution EN 50155:2017, clause 13.4.10 IEC/EN 60068-2-11 Temperature: 35 ±2 °C Duration: 48 h Functional random vibration test EN 50155:2017 clause 13.4.11.4 EN 61373:2010 clause 8, class B, body mounted 1 Acceleration amplitude: 0.1 gn = 1.01 m/s2 Frequency band: 5 – 150 Hz Test duration: 30 min (10 min in each axis) Simulated long life testing EN 50155:2017 clause 13.4.11.2 EN 61373:2010 clause 9, class B, body mounted 1 Acceleration amplitude: 0.58 gn = 5.72 m/s2 Frequency band: 5 – 150 Hz Test duration: 15 h (5 h in each axis) Shock test EN 50155:2017 clause 13.4.11.3 EN 61373:2010 clause 10, class B, body mounted 1 Acceleration amplitude: 5.1 g n Bump duration: 30 ms Number of bumps: 18 (3 in each direction) AREMA Part. 11.5.1 class C, D, E, I, J Displacement amplitude: 0.3” (5 – 10 Hz) 0.07” (5 – 20 Hz) Acceleration amplitude: 1.5 gn = 14.7 m/s2 (10 – 200 Hz) Frequency: 5 – 200 Hz Test duration: 12 h (4 h in each axis) Acceleration amplitude: 10 g n = 98 m/s2 Bump duration: 11 ms Number of bumps: 18 (3 in each direction) Vibration sinusoidal Mechanical shock 1 Status AREMA Part. 11.5.1 class C, D, E, I, J Converter not operating Operating perf. crit. A Not operating Operating perf. crit. A Operating perf. crit. A Operating perf. crit. A Body mounted = chassis of a railway coach Temperatures Table 8: Temperature specifications, valid for an air pressure of 700 – 1200 hPa (700 – 1200 mbar) Model RCM500 RCM1000 EN 50155:2017 Class OT4 Characteristics TA Ambient temperature TC Case temperature 1 TS Storage temperature Unit EN 50155:2017 Class OT2 Conditions min max 10 min min max 10 min Converter operating - 40 70 85 - 40 55 70 - 40 90 - 55 85 Not operational 2 80/90 3 - 55 °C 85 Measured at the measurement point TC ; see Mechanical Data. RCM1000 can be operated at higher temperature with reduced output power. 3 Maximum case temperature for 110RCM1000 models is 80° C, maximum case temperature for 72RCM1000 models is 90° C. 1 2 Reliability Table 9: MTBF Calculation method According to IEC 61709 / SN-29500 Model MTBF 110RCM500-24DMQF 1 040 000 h 110RCM1000-24DMQF 822 000 h Asia-Pacific +86 755 298 85888 EMEA +353 61 49 8941 North America +1 866 513 2839 tech.support@psbel.com belfuse.com/power-solutions © 2023 Bel Fuse Inc. BCD.00803_AK 30 November 2023 Page 13 of 17 RCM Series 500 / 1000 W DC-DC Converters MECHANICAL DATA Dimensions in mm. (4 x) ø 4.5 JM206d No Paint Zone for ground screw ø 10 mm 92.75 70.5 (4 x) JM204e 6 Heatsink fixation 2x M3 147.05 71.5 66 6 Measuring point of case temperatureTC 123 141 123 9.0 99.65 53.65 53.65 40 7 Vo+ Vo– 46 10.95 RCM500/1000 standard 53.7 9.0 141 99.65 10.95 197 147.05 Heatsink fixation 2x M3 197 209 66 71.5 Measuring point of case temperatureTC 209 5 92.75 70.5 6 4. No Paint Zone for ground screw ø 10 mm 6 ø Vi– Vi+ PE Vo+ Vo– 99.4 Vi– Vi+ PE 99.4 13.9 11.6 53.7 7 7 RCM500/1000 with option K Vo+ Vo– Vi– Vi+ PE Vo+ Vo– Fig. 11 Case for RCM500 (RCM03), Aluminum, EP powder-coated; 1160 g. Fig. 12 Case for RCM1000 (RCM04), Aluminum, EP powder-coated; 1250 g. pluggable connector European Projection 6 JM246 Vi– Vi+ PE 17.7 Fig. 13 Case detail for RCM500/1000 with option K Asia-Pacific +86 755 298 85888 EMEA +353 61 49 8941 North America +1 866 513 2839 tech.support@psbel.com belfuse.com/power-solutions © 2023 Bel Fuse Inc. BCD.00803_AK 30 November 2023 Page 14 of 17 RCM Series 500 / 1000 W DC-DC Converters SAFETY AND INSTALLATION INSTRUCTION CONNECTORS AND PIN ALLOCATION - Input connector, 3 pins: Wago 745-353: Vi+, Vi–, PE; wire sections: RCM500 /1000: 0.2 – 6 mm 2, 24 – 10 AWG; with option K: Weidmüller 1048500000  - Output connector, 2 pins: Wago 745-652/006-000: Vo+, Vo; wire sections: RCM500/1000: 0.2 – 16 mm2, 24 – 06 AWG RCM500 with option K: Weidmüller 1048390000 RCM1000 with option K: Weidmüller 1156650000 n.c. SD n.c. SD0 T n.c. n.c. OK0 OK2 R– T OK0 OK1 R+ R Pin 1 R  - Auxiliary connector: Phoenix Contact 1874043, pin allocation see fig. 14. Fig. 14 Auxiliary connector pin allocation Installation Instruction These converters are components, intended exclusively for inclusion by an industrial assembly process or by a pro­fessionally competent person. Installation must strictly follow the national safety regulations in respect of the enclosure, mounting, creepage distances, clearances, markings and segregation requirements of the end-use application. Connection to the system shall only be effected with cables with suitable section (primary and secondary connector in cage clamp technique). The auxiliary connector shall be connected via the suitable female connector; see Accessories. Other installation methods may not meet the safety requirements. Check that PE is safely connected to protective earth. No fuse is incorporated in the converter (except for option F). An external circuit breaker or a fuse in the wiring to one or both input pins. Do not open the converters, or the warranty will be invalidated. Make sure that there is sufficient airflow available for convection cooling and that the temperature of the bottom plate is within the specified range. This should be verified by measuring the case temperature at the specified measuring point, when the converter is operated in the end-use application. TC max should not be exceeded. Ensure that a failure of the converter does not result in a hazardous condition. Standards and Approvals The RCM Series converters are approved according to the last edition of IEC/EN 62368-1 and UL/CSA 62368-1. They have been evaluated for: • Class I equipment • Building in • Double or reinforced insulation based on 250 VAC or 240 VDC between input and output, and between input and OK signals (relay contacts) • Pollution degree 2 environment The converters are subject to manufacturing surveillance in accordance with the above mentioned safety standards and with ISO 9001:2015, IRIS ISO/TS 22163:2017 certified quality and business management system. Cleaning Liquids and Protection Degree The converters are not hermetically sealed. In order to avoid possible damage, any penetration of liquids shall be avoided. The converters correspond to protection degree IP 20. Asia-Pacific +86 755 298 85888 EMEA +353 61 49 8941 North America +1 866 513 2839 tech.support@psbel.com belfuse.com/power-solutions © 2023 Bel Fuse Inc. BCD.00803_AK 30 November 2023 Page 15 of 17 RCM Series 500 / 1000 W DC-DC Converters Railway Applications The RCM Series converters have been designed observing the railway standards EN 50155:2021, EN 50121-3-2:2016, EN 50124-1:2017 and AREMA. All boards are coated with a protective lacquer. The converters comply with the fire & smoke standard EN 45545:2016, HL1 to HL3. Insulation Test The electric strength test is performed in the factory as routine test in accordance with EN 62911, EN 50155:2021 and AREMA. It should not be repeated in the field, and the Company will not honor warranty claims resulting from incorrectly executed electric strength tests. Table 10: Isolation Characteristics Input to Output to Case Output 1 Case + Output Factory test 10 s 4.2 2.86 AC test voltage equivalent to factory test 3.0 Insulation resistance Creepage distances Electric strength test 1 2 OK contacts to Unit Input Case Outputs 2.86 2.86 2.86 2.86 kVDC 2.0 2.0 2.0 2.0 2.0 kVAC >300 2 >300 2 >300 >300 >300 >300 MΩ 5.0 3.5 3.5 3.5 3.5 3.5 mm Pretest of subassemblies in accordance with IEC/EN 62368-1 Tested at 500 VDC Asia-Pacific +86 755 298 85888 EMEA +353 61 49 8941 North America +1 866 513 2839 tech.support@psbel.com belfuse.com/power-solutions © 2023 Bel Fuse Inc. BCD.00803_AK 30 November 2023 Page 16 of 17 RCM Series 500 / 1000 W DC-DC Converters ACCESSORIES Female Connector A suitable 16 pin female connector is available; see fig. 15. For converters RCM500/1000 with option K, use (see fig. 16): • HZZ00303-G (3 poles, Weidmüller 1060580000) for RCM500/1000 • HZZ00302-G (2 poles, Weidmüller 1060550000) for RCM500 • HZZ00304-G (2 poles, Weidmüller 1156600000) for RCM1000 Wire section: 0.5 – 10 mm 2, 24 – 8 AWG Fig. 15 Female connector 16 pins, HZZ00146-G (Phoenix Contact 1790357) Fig. 16 Female connectors for RCM500/1000 with option K Additional Heatsink A suitable heat sink (HZZ00149-G) for free air cooling is available, if cooling by wall or a chassis mounting is not possible; see fig. 17. 6 Visible surface 16± 0.2 A-A 6 C 71.5±0.2 D 66 ±0.1 135 67.5±0.2 B A A (209) 90° Ø6 R 6 >6 8 ±1 6 M4 0.2 Ø 3.4 B (4x) D (2x) C (2x) Fig. 17 Additional heatsink for RCM500 and RCM1000 (HZZ00149-G) Weight 530 g Content: Heatsink + 2 screws (M3 x 6 mm) .5 Ø4 6 NUCLEAR AND MEDICAL APPLICATIONS - These products are not designed or intended for use as critical components in life support systems, equipment used in hazardous environments, or nuclear control systems. TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending on the date manufactured. Specifications are subject to change without notice. Asia-Pacific +86 755 298 85888 EMEA +353 61 49 8941 North America +1 866 513 2839 tech.support@psbel.com belfuse.com/power-solutions © 2023 Bel Fuse Inc. BCD.00803_AK 30 November 2023 Page 17 of 17
110RCM1000-24DMQF 价格&库存

很抱歉,暂时无法提供与“110RCM1000-24DMQF”相匹配的价格&库存,您可以联系我们找货

免费人工找货