IXP Series
3 Watt DC-DC Converters
Input voltage range up to 72 V DC 1 or 2 outputs up to 30 V DC 3500 V DC I/O electric strength test voltage • High input to output isolation • Wide input range • Short circuit protection
Selection chart
Output 1 Uo nom Io nom [V DC] [mA] 5 500 5 500 12 250 12 250 15 200 15 200 +5 250 +5 250 +12 125 +12 125 +15 100 +15 100 5 250 5 250 12 125 12 125 15 100 15 100 Output 2 Uo nom Io nom [V DC] [mA] –5 250 –5 250 –12 125 –12 125 –15 100 –15 100 5 250 5 250 12 125 12 125 15 100 15 100 Input voltage Ui [V DC] 9...36 18...72 9...36 18...72 9...36 18...72 9...36 18...72 9...36 18...72 9...36 18...72 9...36 18...72 9...36 18...72 9...36 18...72 Rated power TA = 7 1°C Po tot [W] 2.5 2.5 3 3 3 3 2.5 2.5 3 3 3 3 2.5 2.5 3 3 3 3 Type Option
24 IXP 3-05-7 48 IXP 3-05-7 24 IXP 3-12-7 48 IXP 3-12-7 24 IXP 3-15-7 48 IXP 3-15-7 24 IXP 3-0505-7 48 IXP 3-0505-7 24 IXP 3-1212-7 48 IXP 3-1212-7 24 IXP 3-1515-7 48 IXP 3-1515-7 24 IXP 3-05-05-7 48 IXP 3-05-05-7 24 IXP 3-12-12-7 48 IXP 3-12-12-7 24 IXP 3-15-15-7 24 IXP 3-15-15-7
S S S S S S S S S S S S -
Input
Input voltage Reverse voltage protection continuous range, 24 V continuous range, 48 V shunt diode 9...36 V DC 18...72 V DC
Output
Output voltage setting accuracy Minimum load Line regulation Load regulation Output voltage switching noise Efficiency
Ui nom, lo nom recommended Ui min...Ui max , lo nom Ui nom, 0...100% lo nom, single output models dual output models Ui nom, 20...100% lo nom, peak-peak, total Ui nom, lo nom
±2% Uo nom 20% lo nom ±1% Uo nom 2% Uo nom max. 3% Uo nom max. 3% Uo nom up to 81%
www.power-one.com
1
Board Mountable
Control and protection
Overload protection No-load protection Remote Shut down
IXP Series
Ui min, full load
positive logic (floating or high signal = on) 125% Pi nom
Safety and EMC
Electric strength test voltage Electromagnetic interference I/O conducted with external filter 3500 V DC class B
Environmental
Operating ambient temperature Ui nom , lo nom Storage temperature non operational Relative humidity non condensing MTBF MIL-HDBK-217F, N2 –25...71 °C –40...100 °C 95% >3'700'000 h
Options
Industry standard pinout S
Accessories
DIN and chassis mounting bracket
Mechanical data
Tolerances ±0.3 mm (0.012") unless otherwise indicated.
31.8 (1.25") 2.54 (0.1")
European Projection
Industry standard
Pin 2 3 9 10 11 14 15 16 22 23 Single output Vi– Vi– n.c. n.c. n.c. Vo+ n.c. Vo– Vi+ Vi+ Dual output Vi– Vi– COM n.c. Vo– Vo+ n.c. COM Vi+ Vi+
15.24 (0.6")
20.3 (0.8")
Measuring point of case temperature TC
Alternative pinout
S09034
ø 0.5 (0.02")
Pin 1 2 9 10 11 12 13 15 16 20 23 24
Single output Dual output Double output Vi+ Vi+ Vi+ Vi+ Vi+ Vi+ Go1 COM COM Vo– Vo1 Vo+ Vo– Vo2 Vo+ Go2 SD SD SD Vi– Vi– Vi– Vi– Vi– Vi–
3 (0.12")
12 (0.47")
www.power-one.com