FXP6000

FXP6000

  • 厂商:

    POWER-ONE

  • 封装:

  • 描述:

    FXP6000 - Distributed Power Front-End - Power-One

  • 数据手册
  • 价格&库存
FXP6000 数据手册
FXP6000 AC-DC Series Data Sheet r Front-End Distributed Powe Features • Three-phase AC input • Suitable for 3U or 5U height mounting • Single-wire current share or Droop current share • Remote voltage adjust and current monitoring • Overtemperature, overload, and overvoltage protection • LED supply status indicators • Current-share control for up to 30 units • Standard & customized rack adaptors available • Front panel selectable-input-range model availability FXP6000 Front and Rear Views • (For higher power requirements, see FXP7000) • (For chassis-mount requirements, see FXC6000 OR FXC7000) Description The FXP6000 Series of rack-mounted power systems provides AC front-end capability to automatic test equipment, telecom, data communications, and other distributed power designs. The FXP systems may be paralleled up to 180 kW of output power. The FXP family is hot pluggable and includes paralleling (OR-ing) diodes. These power supplies provide excellent protection against input voltage transients. The FXP family power supplies may be plugged into or removed from an operating system when used in a redundant power configuration. Access to interfaces for remote sensing, remote voltage adjust, current sharing, current monitoring, power supply status, standby voltage and inhibit, as well as power connections, is through a connector at the rear of the supply. The FXP has its fan, handles, voltage adjust, and indicator lights on the front panel and a single hot-plug connector on the rear. Airflow is from the front through the rear. Alarm, monitoring, and control signals are floating from the main output and can be referenced to the positive or negative output or sense line of the power supply. The output is floating with respect to the chassis and may be used as a positive or negative polarity supply. The FXP6000 Series meets international safety requirements and is CE Marked to the Low Voltage Directive. This series operates on three-phase European voltages as well as (up to) 480VAC, delta or wye. Hot-Pluggable Model Selections MODEL OUTPUT VOLTAGE INPUT VOLTAGE RANGE 3-PHASE (VAC) ADJUSTMENT RANGE MAXIMUM OUTPUT CURRENT LINE REGULATION LOAD REGULATION (NOTE 1) INITIAL SETTING ACCURACY FXP6000-32-S (NOTE 2) 32V FXP6000-48-S (NOTE 2) 48V 180 to 264 or 342 to 528 180 to 264 or 342 to 528 30.5 to 33.5V 45.6V to 50.4V 175A 125A 0.2% 0.15% 0.2% 0.2% 31.93V to 32.07V 47.90V to 48.10V NOTES: 1) With Remote Sense connected. 2) User-selectable input voltage ranges. Input Specifications PARAMETER DESCRIPTION/CONDITIONS MIN NOM MAX UNITS Input Voltage - AC Input Current Inrush Surge Current Input Frequency Hold-up Time Operating Frequency Power Factor 3-phase delta low input range, nominal. 3-phase delta high input range, nominal. Continuous deviation from the above nominals. Per phase at full rated load. FXP6000 at 180 VAC: Internally limited. Vin = 264VAC (one cycle). 25° C: Vin = 528VAC (one cycle). 25° C: AC input. After last AC line peak at full power. 208 VAC: 410 VAC: Switching frequency, fixed. 200 380 -10 50 20 20 100 0.90 240 480 +10 28 38 38 60 VAC % ARMS APK Hz ms kHz W/VA FEB 11, 2005 revised to JAN 09, 2007 Page 1 of 8 www.power-one.com FXP6000 AC-DC Series Data Sheet Output Specifications PARAMETER DESCRIPTION/CONDITIONS MIN NOM MAX UNITS Output Voltage Adjustment Range Output Power Output Current Efficiency Regulation An additional 1.0 Volt is provided to the output terminals to provide for load lead losses. Continuous duty rating. Continuous duty rating. Full rated load (208Vac). 32V Models: 48V Models: 32V Models: 48V Models: 32V Models: 48V Models: 32V Models: 48V Models: 30.4 45.6 32 48 33.6 50.4 5600 6000 175 125 V Watts A % 85 88 88 91 0.2 0.75 2.0 0.2 1 2 0 Ripple & Noise Overshoot / Undershoot Minimum Loads Transient Response Turn-On Delay Turn-on Rise Time Load, Maximum deviation with 0 to 100% load change: With Remote Sense connected: With Remote Sense not connected: Utilizing Droop Current Share: Line, Under all specified operating conditions. Measured at mating connector w/ 0.01µF + 10µF Tant. 20 MHz BW: 100 MHz BW: Output voltage overshoot/undershoot at turn-on. Minimum loading required to maintain regulation. Maximum recovery time, to within 1% of initial set Time: point due to a 25% load change, 1A/µs. Deviation: Time required for initial output voltage stabilization after power-up. Time required for output voltage to rise from 10% to 90%. % % p-p % A µs % s ms 0 400 3 3 100 Interface Signals and Protection PARAMETER (NOTE 1,2) DESCRIPTION/CONDITIONS MIN NOM MAX UNITS AC Power Fail Warning Auxiliary Power Current Monitor Current Share Input Range Select Status Loss of Phase Warning Output Inhibit Output Interlock Output Overload Protection Output Overload Warning Output Short Circuit Protection Output Voltage Fault Signal Output Voltage Margin Overtemperature/ Fan Failure Warning Overvoltage Protection Power Supply Present Signal Remote Sense Warning provided prior to Vout dropping 5% after loss of AC input. Output voltage - diode isolated. Inclusive of line, load, and initial tolerances. Output current. Monitor output current over a compliance range of 0~10V. Nominal full load output: 50-100% load tolerance: 10%. Passive: Maximum signal resistance in high input voltage range selection. Warning provided prior to protective reduction in current limit. Voltage required to enable supply (0.5 mA sink). (NOTE 3) Voltage required to enable supply (6 mA sink). (NOTE 3) Straight line current limit (above approx. 5V Vout). 32V Models: 48V Models: Signal level on overload. Occurs on overload when Vout is below approx. 5V. 32V Models Iavg: May operate in burst-mode. 48V Models Iavg: Deviation from adjusted Vout that is considered as a fault. Output voltage swing available through Margin pin (analog). Time between fault warning and shutdown. Latching shutdown. Latch style overvoltage protection. FXP6000-32: FXP6000-48: Resistance to logic ground upon insertion of supply. Maximum load lead loss compensation (round trip). 5 11.5 12.0 12.7 500 ms V mA mA µA/A µA/A % -315 -250 12.5 0 0 315 500 5 10 0.10 1.0 1.0 188 134 105 65 ±5 ±5.2 500 ms V V A V A % % ms V V 180 129 2.2 30 21 ±3 ±4.8 100 36.3 55.2 ±4 ±5.0 38.4 57.6 1000 40.5 60.0 1.0 NOTES: 1) All logic outputs listed below feature a standard active pull-down output with 0.4V max at 40 mA sink capability, and a 100k pull-up to 5V. 2) In addition to those listed below, signals and front-panel LEDs are provided to indicate: overtemperature/fan fault, AC phase imbalance, output good, interlock open, and supply inhibited. The FXP also provides 4 LED’s indicating output loading. 3) Both signals must be pulled to logic ground for the unit to operate. Enables are 100% redundant internally for applications where redundant inhibit is desirable. Contact factory for additional design details. FEB 11, 2005 revised to JAN 09, 2007 Page 2 of 8 www.power-one.com FXP6000 AC-DC Series Data Sheet Safety, Regulatory, and EMI Specifications PARAMETER CONDITIONS/DESCRIPTION MIN NOM MAX UNITS Agency Approvals Electromagnetic Interference ESD Susceptibility Radiated Susceptibility EFT/Burst Input Transient Protection Voltage Sag Immunity Leakage Current UL60950/CSA60950-00 (cULus), IEC60950, EN60950 (TÜV), CE marked for the Low Voltage Directive FCC CFR title 47 Part 15 Sub-Part B - Conducted. EN55022 / CISPR 22 Conducted. Per EN61000-4-2, level 4. Per EN61000-4-3, level 3. Per EN61000-4-4, level 4. Per EN61000-4-5. Line-to-Line: Line-to-Ground: Per SEMI F47-0200 FXC/FXP7000 Per UL60950 and FXP6000 at 240 VAC, 60 Hz: EN60950: FXP6000 at 400 VAC, 50 Hz: FXP6000 at 480 VAC, 60 Hz: A A 8 10 ±4 4 3 Pending 5 7 10 Class kV V/M kV kV mA Environmental Specifications PARAMETER CONDITIONS/DESCRIPTION MIN NOM MAX UNITS Altitude Operating Temperature Storage Temperature Temperature Coefficient Relative Humidity Shock Vibration Airflow Operating. Non-Operating. At 100% load: At 60% load: 0°C to 70°C (after 15-minute warm-up). Non-Condensing. Operating: half-sine 10 ms, 3 axis Non-operating: half-sine 10 ms, 3 axis Operating: swept sine 5-2000-5 Hz, 5-32 Hz, 0.02îDA, 32-2000 Hz Non-operating: random 10-2000 Hz Airflow provided through the supply from front to rear. 0 -40 10k 40k 50 70 85 .02 95 +20 +40 1 6.15 135 3.8 483 2.5 ASL Ft. °C °C %/°C %RH GPK GPK Grms cfm m3/min lfm m/s lb kg Weight 29 13 NUCLEAR AND MEDICAL APPLICATIONS - Power-One products are not designed, intended for use in, or authorized for use as critical components in life support systems, equipment used in hazardous environments, or nuclear control systems without the express written consent of the respective divisional president of Power-One, Inc. TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending on the date manufactured. Specifications are subject to change without notice. FEB 11, 2005 revised to JAN 09, 2007 Page 3 of 8 www.power-one.com FXP6000 AC-DC Series Data Sheet FXP6000 Overall Size: 16.96" x 8.00" x 5.00" (430.8mm x 203.2mm x 127.0mm) 16.09" (408.7mm) 14.259" (362.18mm) 11.704" (297.28mm) MAINTAIN 25 SQ IN MIN FREE AREA (FRONT AND REAR) FOR AIR COOLING A A A A 7.509" (190.73mm) 4.954" (125.83mm) 0.87" (22.1mm) LOCK HANDLE LED HANDLE 5.750" (146.05mm)
FXP6000 价格&库存

很抱歉,暂时无法提供与“FXP6000”相匹配的价格&库存,您可以联系我们找货

免费人工找货