HHD25 DC/DC Series Data Sheet
20/25A Half-Brick
Features
•
•
•
•
•
•
•
•
•
•
•
•
Applications
•
•
•
•
Distributed power architectures
Telecommunications equipment
LAN/WAN applications
Data processing applications
•
•
•
100/85 Watt total output power
Independently-regulated outputs
Flexible load distribution
Open-frame design with Insulated Metal
Substrate
Low profile – 12.7mm height
High efficiency - 87%
Output voltage tracking
Output overcurrent protection
Output overvoltage protection
Overtemperature protection
Setpoint accuracy ± 1.5%
Independent output voltage trim, positive or
negative
Input/output isolation: 1500VDC
Basic insulation
UL 1950 Recognition, CSA 22.2 No. 950-95
certification, TUV IEC950
Description
The HHD25 is a series of high density Half-brick size, High current, Dual output DC/DC converters with throughhole mounting. The products provide onboard conversion of standard telecom and datacom input voltages to two
independently-regulated output voltages. Leading-edge technology provides extremely high efficiency and
superior thermal performance which enables the products to deliver full-rated power at 55°C ambient temperature
with only 200 LFM forced air without the addition of a heatsink. The outputs also track each other during both
startup and shutdown.
Model Selection
Model
Input
Current,
Max, ADC
3.6
Output
Voltage,
VDC
5.0/3.3
Output Rated
Current, ADC
HHD20ZGE
Input
Voltage
Range, VDC
36-72
HHD20ZGB
36-72
3.6
5.0/1.8
20/20
100
85
HHD25ZED
36-72
3.1
3.3/2.5
25/20
100
85
20/20
Output Ripple
and Noise, mV
p-p
100
Typical
Efficiency
%
87
HHD25ZEB
36-72
3.1
3.3/1.8
25/20
100
84
HHD20YGE
18-36
7.2
5.0/3.3
20/20
100
85
REV. SEP 17, 2003
Page 1 of 8
HHD25 DC/DC Series Data Sheet
20/25A Half-Brick
Absolute Maximum Ratings
Stresses in excess of the absolute maximum ratings may cause performance degradation, adversely effect longterm reliability, and cause permanent damage to the converter.
Parameter
Input voltage
Conditions/Description
Continuous
Transient, 100ms
Min
36
Max
75
100
Units
VDC
VDC
Operating Temperature
At 100% load
-40
100
°C
-40
125
°C
50
VDC
Storage Temperature
ON/OFF Control Voltage
Referenced to -Vin
Environmental and Mechanical Specifications
All specifications apply over specified input voltage, output load, and temperature range, unless otherwise noted.
Parameter
Conditions/Description
Vibration
Halfsine wave, 10-55 Hz, 3 axes,
5 min each
Min
Weight
Nom
Max
Units
5
g
2.3/68
Water Washing
Standard Process
Yes
MTBF
Per Bellcore TR-NWT-000332
1,780
Oz/g
kHrs
Isolation Specifications
All specifications apply over specified input voltage, output load, and temperature range, unless otherwise noted.
Parameter
Conditions/Description
Min
Insulation Safety Rating
Nom
Max
Units
Basic
Isolation Voltage
1500
VDC
Isolation Resistance
10
MOhm
Isolation Capacitance
3000
pF
Input Specifications
All specifications apply over specified input voltage, output load, and temperature range, unless otherwise noted.
Parameter
Conditions/Description
Min
Nom
Max
Units
Input Voltage
Continuous
36
48
75
VDC
Turn-On Input Voltage
Ramping Up
33
VDC
Turn-Off Input Voltage
Ramping Down
30
VDC
Turn-On Time
To Output Regulation Band
10
ms
100% Resistive Load
Input Reflected Ripple Current
Full Load, 12µH source inductance
Input Inrush Current Limit
Vin=Vin.max
REV. SEP 17, 2003
Page 2 of 8
80
1
mA p-p
2
As
HHD25 DC/DC Series Data Sheet
20/25A Half-Brick
Output Specifications
All specifications apply over specified input voltage, output load, and temperature range, unless otherwise noted.
Parameter
Conditions/Description
Min
Nom
Output Voltage Setpoint Accuracy
Vin=Vin.nom, Full Load
-1.5
Output Current* Vout1
For MAX see Table
2.0
ADC
Output Current* Vout2
For MAX see Table
2.0
ADC
Line Regulation Vout1
Vin.min to Vin.max, Iout.max
0.2
%Vout
Line Regulation Vout2
Vin.min to Vin.max, Iout.max
1
%Vout
Load Regulation,Vout1,Vout2
Vin=Vnom, Iout.min to Iout.max
1
%Vout
0.5
VDC
4
%Vout
500
µs
Remote Sense Headroom
Dynamic Regulation
Settling Time
to 1% error band
Admissible Load Capacitance
Iout.max, Nom Vin
30,000
Output Current Limit Threshold**
Vout≤0.97Vout.nom
115
Switching Frequency
Non Latching
Trim Range
Units
1.5
%Vout
50-75% load step change
Peak Deviation
Overvoltage Protection,
Max
µF
140
270
%Iout
kHz
Over all input voltage and load
conditions
120
140
%Vout
Iout.max, Vin=Vnom
90
110
%Vout
* At Iout