LES DC-DC Series Data Sheet
Single-Output, 15 Watts
Features
•
•
•
•
•
RoHS lead-solder
exemption compliant
Industry-standard package
Industry-standard pinout
100 °C case operation
Short-circuit protection
•
•
•
•
24 V and 48 V inputs
Input Pi filter and
6-sided shielding
Regulated outputs
1500 V isolation
Description
Technical Specifications
Efficiency vs. Load (24V Input)
85
80
75
EFFICIENCY %
LES DC-DC converters provide up to 15 watts of output
power in an industry-standard package and footprint. With
a maximum case temperature of 100 °C, the LES is well
suited for the most demanding telecom, networking, and
industrial applications. The LES features 1500 VDC
isolation, short circuit protection, and six-sided shielding.
The LES is available with optional enable and voltage trim
pins. Please see the IAD Series for dual output
applications.
Input
70
LES010YE-A
65
EFF. (18v)
60
EFF. (24v)
55
EFF. (36v)
50
Voltage Range
24 VDC Nominal
48 VDC Nominal
Reflected Ripple
18 - 36 VDC
36 - 75 VDC
50 mA
45
10
40
50
60
70
80
90
100
Efficiency vs. Load (48V Input)
±1%
0.2%
Vout
0.5% Vout
10% Iout Rated
25% Iout
2% Vout
500 ms
±10%
Shutdown / Hiccup
110 - 150%
200% Iout
Load Regulation Iout Min. - Iout Max., Vin Nom.
Minimum Output Current
Dynamic Regulation, Loadstep
Pk Deviation
Settling Time
Voltage Trim Range
Short Circuit / Overcurrent Protection
Current Limit Threshold Range, % of Iout Rated
Short Circuit Current Max.
(12Vout & 15Vout : 4.0A when Vout= 0.25V)
85
80
75
EFFICIENCY %
Setpoint Accuracy
Line Regulation Vin Min. - Vin Max., Iout Rated
70
LES010ZE
65
LES015ZG
60
55
50
10
115 -140% Vout Nom.
Second Control Loop
20
30
40
50
60
70
80
90
100
LOAD %
General
Notes
Turn-On Time
10 ms
Remote Shutdown
Positive/Negative Logic
Switching Frequency
400 kHz
Isolation
Input - Output
1500 VD C
Output - Case
500 VD C
Temperature Coefficient
0.02 ppm/ C
Case Temperature
Operating Range
-40 To +100 C
Storage Range
-40 To +100 C
Humidity Max., Non-Condensing
95%
Vibration, 3 Axes, 5 Min Each
5 g, 10 - 55 Hz
M TBF (Bellcore TR-NWT-000332)
2.5 X 106 hrs
† MTBF predictions may vary slightly from model to model.
Specifications typically at 25 °C, normal line, and full load,
unless otherwise stated.
Soldering Conditions: I/O pins, 260 °C, ten seconds; fully
compatible with commercial wave-soldering equipment.
Safety: Agency approvals may vary from model to model.
Please consult factory for specific model information.
Units are water-washable and fully compatible with commercial
spray or immersion post wave-solder washing equipment.
MCD10042 Rev. 1.0, 06-Feb-08
30
LOAD %
Output
Ovp Trip Range
Ovp Type
20
Safety
Page 1 of 2
UL, cUL, T U V
www.power-one.com
LES DC-DC Series Data Sheet
Single-Output, 15 Watts
Model Selection
INPUT VOLTAGE
(VOLTS)
INPUT VOLTAGE
RANGE (VOLTS)
MAXIMUM INPUT
CURRENT (AMPS)*
OUTPUT
VOLTAGE (VOLTS)
RATED OUTPUT
CURRENT (AMPS)
LES008YD
LES010YE
LES015YG
24
24
24
18-36
18-36
18-36
0.6
0.8
1.1
2.5
3.3
5
3.00
3.00
3.00
75
100
100
77%
81%
84%
LES015YH
24
18-36
1.3
12
1.25
120
85%
LES015YJ
24
18-36
1.3
15
1.00
150
86%
LES008ZD
48
36-75
0.35
2.5
3.00
75
77%
LES010ZE
48
36-75
0.4
3.3
3.00
100
81%
LES015ZG
48
36-75
0.6
5
3.00
100
83%
LES020ZG
48
40-60
0.63
5
4.00
100
84%
LES015ZH
48
36-75
0.65
12
1.25
120
86%
LES015ZJ
48
36-75
0.65
15
1.00
150
86%
MODEL
NOTES:
RIPPLE & NOISE
pk-pk (mV)
TYPICAL
EFFICIENCY**
* Maximum input current at minimum input voltage, maximum rated output power.
** At nominal Vin, rated output.
Model numbers highlighted in yellow or shaded are not recommended for new designs.
Mechanical Drawing
Thermal Impedance
Natural Convection
100 LFM
200 LFM
300 LFM
400 LFM
15.4 °C/W
12.2 °C/W
9.3 °C/W
7.4 °C/W
6.4 °C/W
Note:
Thermal impedance data is
dependent on many environmental factors. The exact thermal
performance should be validated
for specific application.
Pin
1
2
3
4
5
6
Tolerances
Function
+Vin
-Vin
no pin
(Optional shutdown
Pin)
+Vout
no pin
(Optional Trim Pin)
-Vout
Inches:
.XX – 0.020
.XXX – 0.010
(Millimeters)
.X – 0.5
.XX – 0.25
Pin:
– 0.002
– 0.05
Case:
+ 0.04, - 0.00
+ 1.0, - 0.00
(Dimensions as listed unless
otherwise
specified.)
NUCLEAR AND MEDICAL APPLICATIONS - Power-One products are not designed, intended for use in, or authorized for use as critical components
in life support systems, equipment used in hazardous environments, or nuclear control systems without the express written consent of the respective
divisional president of Power-One, Inc.
TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending on the date
manufactured. Specifications are subject to change without notice.
MCD10042 Rev. 1.0, 06-Feb-08
Page 2 of 2
www.power-one.com
很抱歉,暂时无法提供与“LES015YH”相匹配的价格&库存,您可以联系我们找货
免费人工找货