LK2320-7R

LK2320-7R

  • 厂商:

    POWER-ONE

  • 封装:

  • 描述:

    LK2320-7R - 150 Watt AC-DC Converters - Power-One

  • 数据手册
  • 价格&库存
LK2320-7R 数据手册
K Series 150 Watt AC-DC Converters Input voltage range from 85...264 V AC 1 or 2 isolated outputs up to 48 V DC 4 kV AC I/O electric strength test voltage LGA • Rugged electrical and mechanical design • Wide input-frequency range from 47...440 Hz • Operating ambient temperature range –40...71 °C with convection cooling Selection chart Output 1 Output 2 Input voltage Uo nom [V DC] 5.1 12 15 24 24 30 48 12 15 24 Io nom [A] 25 12 10 6 6 5 3 6 5 3 Uo nom [V DC] 12 15 24 Io nom [A] 6 5 3 Ui [V AC] 85...264 85...264 85...264 85...264 85...264 85...264 85...264 85...264 85...264 85...264 Efficiency hmin [%] 79 84 84 85 81 83 83 81 83 83 Type Options LK 1001-7R LK 1301-7R LK 1501-7R LK 1601-7R LK 2320-7R LK 2540-7R LK 2660-7R LK 2320-7R LK 2540-7R LK 2660-7R -9, E, D, V, P, T, B1 -9, E, D, P, T, B1 -9, E, D, P, T, B1 -9, E, D, P, T, B1 -9, E, D, P, T, B1 -9, E, D, P, T, B1 -9, E, D, P, T, B1 -9, E, D, P, T, B1 -9, E, D, P, T, B1 -9, E, D, P, T, B1 www.power-one.com Edition 4/04.2001 1 Cassette Style Input Input voltage AC Input frequency Input voltage DC Inrush current limitation wide input range K Series 85...264 V AC 47...440 Hz 88...372 V DC by thermistor Output Efficiency Output voltage setting accuracy Output voltage switching noise Line regulation Load regulation Minimum load Current limitation Operation in parallel Hold-up time Ui nom, Io nom Ui nom, Io nom up to 85% ±0.6% Uo nom IEC/EN 61204, total typ. 90 mVpp Ui min...Ui max, Io nom typ. ±0.3% Uo nom Ui nom, 10...100% Io nom, symmetrical output load typ. 0.5% Uo nom not required 0A rectangular U/I characteristic typ. 110% Io nom by current limitation Ui nom, Io nom 70 ms Control and protection Input fuse Input undervoltage lockout Input overvoltage lockout Input transient protection Output Output overvoltage Overtemperature Output voltage adjustment Inhibit Status indication not user accessible 4 AT typ. 90% Ui min typ. 109% Ui max varistor no-load, overload and short circuit proof suppressor diode in each output switch-off with auto restart TTL input, output(s) disabled if open circuit LEDs: OK, inhibit, overload typ. 130% Uo nom TC typ. 100 °C 0...110% Uo nom Safety Approvals Class of equipment Protection degree Electric strength test voltage EN 60950, UL 1950, CSA 22.2 No. 950 class I IP 30 2 kV AC 4 kV AC 1 kV AC 0.1 kV AC I/case I/O O/case O/O EMC Electrostatic discharge Electromagnetic field Electr. fast transients/bursts Surge Conducted disturbances Electromagnetic emissions IEC/EN 61000-4-2, level 4 (8/15 kV) IEC/EN 61000-4-3, level x (20 V/m) IEC/EN 61000-4-4, level 4 (2/4 kV) IEC/EN 61000-4-5, level 3 (2 kV) IEC/EN 61000-4-6, level 3 (10 V) CISPR 22/EN 55022 criterion A criterion A criterion A criterion A criterion A class B www.power-one.com Edition 4/04.2001 2 K Series Environmental Operating ambient temperature Operating case temperature TC Storage temperature Damp heat Vibration, sinusoidal Shock Bump Random vibration MTBF 150 Watt AC-DC Converters Ui nom, Io nom, convection cooled Ui nom, Io nom non operational IEC/EN 60068-2-3, 93%, 40 °C IEC/EN 60068-2-6, 10...60/60...2000 Hz IEC/EN 60068-2-27, 6 ms IEC/EN 60068-2-29, 6 ms IEC/EN 60068-2-64, 20...500 Hz MIL-HDBK-217F, GB, 40 °C –25...71 °C –25...95 °C –40...100 °C 56 days 0.35 mm/5 gn 100 gn 40 gn 4.9 gn rms 500'000 h Options Extended temperature range –40...71 °C, ambient, operating Electronic inrush current limitation Output voltage adjustment 40...110% Uo nom, excludes features R and vice versa Input and/or output undervoltage monitoring, excludes option V Input and/or output undervoltage monitoring (VME), excludes option D Current sharing Cooling plate -9 E P D0…D9 V0, V2, V3 T B1 Pin allocation Pin 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 LK 1001 Vo1+ Output 1 Vo1– S+ S– R i D V T N P Output 1 Sense Sense Control of Uo1 Inhibit Save data ACFAIL Current sharing Protective earth Input Input LK 1301, LK 1501, LK 1601 Vo1+ Output 1 Vo1+ Vo1– Output 1 Vo1– S+ Sense S– Sense R Control of Uo1 i Inhibit D Save data T N N P P S10010 LK 2000 Vo2+ Output 2 Vo2+ Vo2– Output 2 Vo2– Vo1+ Output 1 Vo1– Output 1 R Control of Uo1 i Inhibit D Save data T N N P P Current sharing Protective earth Input or Neutral Input or Phase Current sharing Protective earth Input Input S10010 Connector type H15 30 26 22 18 14 10 6 Connector type H15 S4 26/28 22 18 14 10/8 32 28 24 20 16 12 8 4 32/30 24 20 16 12 4/6 www.power-one.com Edition 4/04.2001 3 Cassette Style Mechanical data Tolerances ±0.3 mm (0.012") unless otherwise indicated. 159 (6.25") 4.5 (0.18") 7 TE K Series European Projection 9 TE 111 (3U) (4.37") 89 (3.50") Test jacks Option P (Uo) Option D (Uto) Option D (Uti) LED i LED OK LED IoL Measuring point of case temperature TC 50 (1.97") 171.93 (6.77") (DIN 41494) 168.5 (6.63") S09002 6.5 (0.26") 80 (3.15") Accessories Front panels 19" (Schroff/Intermas) Mating H15/H15S4 connectors with screw, solder, fast-on or press-fit terminals Connector retention facilities and code key system for connector coding Chassis or wall mounting plates for frontal access Universal mounting brackets for chassis or DIN-rail mounting www.power-one.com Edition 4/04.2001 4
LK2320-7R 价格&库存

很抱歉,暂时无法提供与“LK2320-7R”相匹配的价格&库存,您可以联系我们找货

免费人工找货