0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
LWN1701-6

LWN1701-6

  • 厂商:

    POWER-ONE

  • 封装:

  • 描述:

    LWN1701-6 - 125 and 250 Watt AC-DC Converters - Power-One

  • 数据手册
  • 价格&库存
LWN1701-6 数据手册
W Series 125 and 250 Watt AC-DC Converters Input range 85...264 V AC with PFC 1 or 2 isolated, regulated outputs up to 96 V 3 kV AC I/O electric strength test voltage LGA • Electrically and mechanically rugged DIN-rail front end • Outputs individually controlled with 150% output peak power • Operating ambient temperature range –40...60 °C with convection cooling Selection chart for front ends Output 1 Uo nom Io nom [V DC] [A] 24.7 5 24.7 10 37 3.3 37 6.6 49.4 2.6 49.4 5 24.7 5 49.4 2.5 Output 2 Uo nom Io nom [V DC ] [A] 24.7 5 49.4 2.5 Input voltage Ui min Ui max Rated power TA = 6 0 °C Po tot [W] 125 250 125 250 125 250 250 250 Type Options1 85...264 VAC (14…440 Hz)3 90…350 VDC LWR-1601-6 LWN-1601-6 LWR 1701-6 LWN 1701-6 LWR 1801-6 LWN-1801-6 LWN-2660-6 LWN 2880-6 R D1…D5 S M2 F, F1 K2 Selection chart for battery chargers Output Uo nom [V DC] 25.7...29.3 25.7...29.3 51.4...58.6 51.4...58.6 1 2 Io nom [A] 4.2 8.45 2.1 4.2 Input voltage Ui min Ui max 85…264 VAC (14…440 Hz)3 90…350 VDC Rated power TA = 6 0 ° C Po tot [W] 115 230 115 230 Type Options1 LWR 1240-6 M1 LWN 1240-6 M1 LWR 1740-6 M1 LWN 1740-6 M1 F, F1 K2 For lead times and minimum order quantity contact Power-One. For availability contact Power-One. 3 Input frequency range certified for 14...440 Hz. For continuous operating frequency 100 Hz contact factory. www.power-one.com Edition 5/07.2001 1 W Series Input Input voltage Input frequency Power factor Inrush current 125 and 250 Watt AC-DC Converters world wide mains, single phase derating information see application note active PFC virtually no inrush current 85...264 V AC 90...350 V DC 14...440 Hz up to 0.99 Output Efficiency Output voltage setting accuracy Output voltage noise Output voltage ripple Line and cross regulation Load regulation Minimum load Current limitation Short term peak power Operation in parallel Hold-up time Ui nom, Io nom up to 89% Ui nom, Io nom ± 1.3% Uo nom IEC/EN 61204 typ. 50 mV sinusoidal output ripple at wice the line frequency ≤1.2 Vpp Ui min...Ui max typ. 50 mV 0...100% Io nom, Ui nom –1.6% Uo nom not required rectangular U/I characteristic 101...112% Io nom 1 s, electronically controlled 150% Io nom enabled by droop current share Io nom, Uo decreases to 80% of Uo nom typ. 15 ms Control Status indication LED output(s) OK Protection Input fuse Input reverse polarity Input undervoltage lockout Input overvoltage lockout Input transient protection Output(s) Output overvoltage Overtemperature not user accessible 6.3 A, slow blow bridge rectifier typ. 80% Ui min typ. 105% Ui max voltage depending resistor (VDR) no-load, overload and short circuit proof second control loop, each output, 24 V/48 V reduced output power if thermally overloaded 30/60 V SELV Safety Approvals Electric strength test voltage EN 60950, UL 1950, CSA22.2 No. 950, UL 508 listed class I, I/case class I, I/O class I, O/case class I, O/O AC-in / DC-in 2 kV AC 3 kV AC 1 kV AC 0.35 kV AC 3/2 IP 20 Pollution degree Degree of protection www.power-one.com Edition 5/07.2001 2 DIN Rail Mountable EMC Electrostatic discharge Electromagnetic field Electr. fast transients/bursts Surge W Series IEC/EN 61000-4-2, level 4, contact/air (8/15 kV) IEC/EN 61000-4-3, level 3 (10 V/m) IEC/EN 61000-4-4, level 4, capacitive/direct (4/2 kV) IEC/EN 61000-4-5, level 3, in and out, line to line (2 kV) level >3, input, line to case (3.5 kV) level 2, output, line to case (1 kV) IEC/EN 61000-4-6, level 3 (10 V) CISPR 22/EN 55022, conducted criterion A criterion A criterion A criterion B criterion B criterion A criterion A class A Conducted disturbances Electromagnetic emissions Environmental Operating ambient temperature Operating case temperature TC Storage temperature Damp heat Shock and vibration Shock Bump Vibration, sinusoidal Vibration, random MTBF Ui nom, Io nom, convection cooled Ui nom, Io nom non operational IEC/EN 60068-2-3, 93%, 40 °C unit wall mounted with brackets IEC/EN 60068-2-27, 11 ms IEC/EN 60068-2-29, 11 ms IEC/EN 60068-2-6, 10...60/60...2000 Hz IEC/EN 60068-2-64, 20...500 Hz MIL-HDBK-217E, GB, 40 °C –40...60 °C –40...87 °C –40...100 °C 56 days 50 gn 25 gn 0.35 mm/5 gn 0.05 g2/Hz >600'000 h Options Input and output undervoltage monitoring Output voltage adjustment 10 V...110% of Uo nom Remote on/off Multi option choice (D1...D5, R, S) via Sub-D connector Built-in second input fuse in the neutral No fuse fittet (for operation from high DC) System connectors with screw terminals D1...D5 R S M1...M2 F F1 K2 www.power-one.com Edition 5/07.2001 3 W Series Mechanical data 125 and 250 Watt AC-DC Converters European Projection Tolerances ±0.3 mm (0.012") unless otherwise indicated. 113.6 (4.47") 106.6 (4.2") 15 (0.59") 118 (4.65") 105 (4.15") 103 (4.05") 29.4 (1.16") 09107 TC Wall mounting brackets (accessory) 138 (5.43") 5 Option M 43 (1.69") 13 (0.51") 1 TA 31 (1.22") TA Measuring point for case temperature TC 49 (1.93") 33 (1.3") www.power-one.com Edition 5/07.2001 4 DIN Rail Mountable Terminal allocation input side Pin 1 2 3 Des. N P Determination Protective earth Input neutral Input phase S10066 W Series 1 2 3 Terminal allocation output side Pin 1 2 3 4 5 6 7 8 9 10 11 Des. + + – – + + – – Aux. Single output Earth to load Output pos. Output pos. Output neg. Output neg. Output pos. Output pos. Output neg. Output neg. Options Earth to load Double output Earth to load Output 1 pos. Output 1 pos. Output 1 neg. Output 1 neg. Output 2 pos. Output 2 pos. Output 2 neg. Output 2 neg. Options Earth to load S10067 1 2 3 4 5 6 7 8 9 10 11 Accessories Mounting brackets for vertical chassis/wall mounting Fixing brackets for enhanced vibrations on DIN-rail Protective covers over input and output terminals www.power-one.com Edition 5/07.2001 5
LWN1701-6 价格&库存

很抱歉,暂时无法提供与“LWN1701-6”相匹配的价格&库存,您可以联系我们找货

免费人工找货