MAP130 AC-DC Series Data Sheet
Features
• • • • • • • • • RoHS lead-solder-exempt compliant Automatic 115/230 input voltage selection All outputs fully regulated Remote sense, overvoltage protection, and overtemperature protection Power Fail signal included Greater than 100,000 Hour MTBF U-Channel chassis: 8.50" x 4.50" x 2.00" (215.9mm x 114.3mm x 50.8mm) Optional cover Metric and SAE mounting inserts
Description Power-One’s MAP130 Series of single and multiple output power supplies provide fully-regulated outputs with high peak current capabilities in a compact 4.50" x 8.50" x 2.00" U-channel chassis. Other standard features include autoselect AC input, EMI level B filtering, power fail, thermal shutdown (with warning), remote sense, and metric and SAE mounting inserts. This convection-cooled series is designed for use in commercial and industrial environments in temperatures up to 50°C. All products are approved to the latest international regulatory standards and display the CE Mark.
Single Output Model Selection
MODEL OUTPUT VOLTAGE ADJUSTMENT RANGE CONTINUOUS CURRENT PEAK CURRENT (NOTE 3) LINE REGULATION LOAD REGULATION TYPICAL RIPPLE & INITIAL SETTING NOISE %p-p (NOTE 1) ACCURACY
MAP130-1005 MAP130-1012 MAP130-1024
5V 12V/15V 24V/28V
4.75V to 5.50V 11.4V to 15.75V 22.5V to 30.0V
26A 12A/10A (Note 2) 6.2A/5.4A (Note 2)
30A 13.8A/11A 6.8A/5.9A
0.2% 0.2% 0.2%
1% 1% 1%
1% 1% 1%
5.1V to 5.2V 12.0V to 12.2V 23.9V to 24.1V
NOTES: 1) Typical peak to peak noise expressed as a percentage of output voltage, 20MHz bandwidth. 2) MAP130-1012 output currents are expressed as 12V/15V operation. MAP130-1024 output currents are expressed as 24V/28V operation. 3) Peak load for 60 seconds or less are acceptable, 10% duty cycle, maximum.
Multiple Output Model Selection – 130W Continuous Output Power
MODEL OUTPUT VOLTAGE ADJUSTMENT RANGE OUTPUT CURRENT PEAK CURRENT (NOTE 1) LINE REGULATION LOAD REGULATION TYPICAL RIPPLE & INITIAL SETTING NOISE %p-p (NOTE 2) ACCURACY
MAP130-4000
MAP130-4001
MAP130-4002
MAP130-4003
+5V +12V -5V -12V +5V +24V -12V +12V +5V +12V -12V +12V +5V +15V -5V -15V
4.75V to 5.50V 11.5V to 12.5V Fixed Fixed 4.75V to 5.50V 23.0V to 25.0V Fixed Fixed 4.75V to 5.50V 11.5V to 12.5V Fixed Fixed 4.75V to 5.50V 14.0V to 16.0V Fixed Fixed
20A 5A 1A 1A 20A 3.5A 1A 1A 20A 5A 1A 1A 20A 4A 1A 1A
30A 10A 1A 1A 30A 5A 1A 1A 30A 10A 1A 1A 30A 8A 1A 1A
0.2% 0.5% 0.5% 0.5% 0.2% 0.5% 0.5% 0.5% 0.2% 0.5% 0.5% 0.5% 1% 1% 2% 2%
1% 2% 2% 2% 1% 2% 2% 2% 1% 2% 2% 2% 1% 2% 2% 2%
1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1%
5.1V to 5.2V 11.75V to 12.0V -4.8V to -5.2V -11.6V to -12.4V 5.1V to 5.2V 23.9V to 24.1V -11.6V to -12.4V -11.6V to -12.4V 5.1V to 5.2V 11.9V to 12.1V -11.6V to -12.4V 11.6V to 12.4V 5.1V to 5.2V 15.0V to 15.1V -4.8V to -5.2V -14.7V to -15.3V
JUN 14, 2006 revised to AUG 10, 2006
Page 1 of 4
www.power-one.com
MAP130 AC-DC Series Data Sheet
Multiple Output Model Selection (Cont.) – 130W Continuous Output Power
MODEL OUTPUT VOLTAGE ADJUSTMENT RANGE OUTPUT CURRENT PEAK CURRENT (NOTE 1) LINE REGULATION LOAD REGULATION TYPICAL RIPPLE & INITIAL SETTING NOISE %p-p (NOTE 2) ACCURACY
MAP130-4004
MAP130-4010
MAP130-4020
+5V +24V -15V +15V +5V +12V -5V -12V +5V +12V -12V -5V
4.75V to 5.50V 23.0V to 25.0V Fixed Fixed 4.75V to 5.50V 11.5V to 12.8V Fixed Fixed 4.75V to 5.50V 11.5V to 12.8V Fixed Fixed
20A 3.5A 1A 1A 20A 5A 1A 3A 20A 5A 1A 3A
30A 5A 1A 1A 30A 10A 1A 3A 30A 10A 1A 3A
0.2% 0.5% 0.5% 0.5% 0.2% 0.5% 0.5% 0.5% 0.2% 0.5% 0.5% 0.5%
1% 2% 2% 2% 1% 2% 2% 2% 1% 2% 2% 2%
1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1%
5.15V to 5.2V 23.9V to 24.1V -14.5V to -15.5V 14.5V to 15.5V 5.1V to 5.25V 11.75V to 12.0V -4.8V to -5.2V -11.6V to -12.4V 5.1V to 5.25V 11.75V to 12.0V -11.6V to -12.4V -4.8V to -5.2V
NOTES: 1) Peak loads up to 165 Watts, (total of all outputs), for 60 seconds or less are acceptable, (10% duty cycle max.). 2) Maximum peak to peak noise expressed as a percentage of output voltage, 20MHz bandwidth.
Input Specifications
PARAMETER CONDITIONS/DESCRIPTION MIN NOM MAX UNITS
Input Voltage- AC Input Frequency Brown out Protection Hold-up Time Input Current Input Protection Inrush Surge Current Operating Frequency
Auto-ranging.
Low Range High Range
AC Input. Lowest AC input voltage that regulation is maintained with full rated loads. Nominal AC input voltage (115 VAC). 130W load: 90 VAC, 130W load. Non-user serviceable internally located AC input line fuse. Internally limited by thermistor. Vin = 264 VAC (one cycle). 25° C. Switching frequency of main transformer (variable). Range:
90 175 47 90 40
115 230
132 264 63
VAC Hz VAC mS ARMS APK kHz
3.3 38 120
16
Output Specifications
PARAMETER CONDITIONS/DESCRIPTION MIN NOM MAX UNITS
Efficiency Minimum Loads
Ripple and Noise Output Power Overshoot /Undershoot Regulation Transient Response Turn-on Delay Turn-on Rise Time
Full Load, 115VAC. Varies with distribution of loads among outputs. MAP130-1012. MAP130-1024. MAP130-1005 and all multiple output models, main channel only. Full load, 20MHz bandwidth. Continuous output power, all multiple output models. Peak output power (60s maximum, 10% duty cycle), all multiple output models. Output voltage overshoot/undershoot at turn-on / turn-off Varies by output, Total regulation includes: line changes from 90-132 VAC or 175-264, changes in load starting at 20% load and changing to 100% load. Recovery time to within 1% of initial set point due to a 50-100% load change, 4% max. deviation. (Main output only on multi-output units) Time required for initial output voltage stabilization. Time required for output voltage to rise from 10% to 90%.
71 80 1.25 0.63 3.00 See Model Selection Chart 130 165 1 See Model Selection Chart 500 2 20
% Amps
Watts %
µS Sec mS
MAY 13, 2005 revised to JUN 14, 2006
Page 2 of 4
www.power-one.com
MAP130 AC-DC Series Data Sheet
Interface Signals and Internal Protection
PARAMETER CONDITIONS/DESCRIPTION MIN NOM MAX UNITS
Overvoltage Protection
Provided on single output units and only the main output of multiple output units.
Overcurrent Protection Remote Sense Power Fail Warning (Note 1) Overtemperature Warning (Note 2)
MAP130-1012 17.0 MAP130-1024 32.0 MAP130-4004 6.2 All other models. 5.5 All models have inherent short circuit protection. Units will automatically restart at the removal of the fault. Total voltage compensation for main output cable losses. Logic LO (denotes power fail detected). Logic HI with internal pull-up to output. 10 Power Fail trip point, maximum load, decreasing line. 86 Time before regulation dropout, at full load, due to loss of input power. 5 Warning prior to system shutdown due to excessive internal temperatures. 20 Shifts Power Fail signal to a logic LO state.
22.0 37.0 7.4 6.8 250 0.7 94
VDC
mV V k VAC mS mS
NOTES: 1) Power Fail not available on MAP130-1012 and MAP130-1024. 2) MAP130-1012 and MAP130-1024 have overtemperature protection, but do not have the warning feature.
Safety, Regulatory, and EMI Specifications
PARAMETER CONDITIONS/DESCRIPTION MIN NOM MAX UNITS
Agency Approvals
Dielectric Withstand Voltage Electromagnetic Interference, ESD Susceptibility Radiated Susceptibility EFT/Burst Input Transient Protection Insulation Resistance Leakage Current
UL1950. CSA 22.2 No. 234/950. EN60950 (TÜV). Input to Output, 1 second. FCC CFR title 47 Part 15 Sub-Part B - Conducted EN55022 / CISPR 22 Conducted EN55022 / CISPR 22 Radiated (Note 1) Per EN61000-4-2, level 4 Per EN61000-4-3, level 3 Per EN61000-4-4, level 3 (Note 2) Per EN61000-4-5 class 3 Input to output Per EN60950 (264 VAC)
Approved 2600 B B B 8 10 ±2 Line to Line 1 Line to Ground 2 7 700 VDC Class kV V/M kV kV M µA
NOTES: 1) MAP130-1005 meets Class A, radiated. 2) MAP130-1005, MAP130-4003, and MAP130-4010, meet level 2, ±1kV.
Environmental Specifications
PARAMETER CONDITIONS/DESCRIPTION MIN NOM MAX UNITS
Altitude Operating Temperature
Operating Non-Operating Derate linearly above 50°C by 2.5% per °C At 100% load: At 50% load: 0 -40 0°C to 70°C (after 15 minute warm-up period) Non-Condensing Operating, peak acceleration Random vibration, 10Hz to 2kHz, 3 axis ±0.02 5
Storage Temperature Temperature Coefficient Relative Humidity Shock Vibration
10K 40K 50 70 85 ±0.05 95 20 6
Feet °C °C °C %/°C %RH GPK GRMS
Options
DESCRIPTION NOTES DIMENSIONS
Cover
Add ‘C’ suffix to model number or order part number 412-59586-G separately. For convection cooled applications with covers, derate output power as follows: Derate all multiple output models and MAP130-1005 to 120 watts. Derate MAP130-1012 and MAP130-1024 to 140 watts.
8.50" x 4.50" x 2.40" (215.9mm x 114.3mm x 61.0mm)
JUN 14, 2006 revised to AUG 10, 2006
Page 3 of 4
www.power-one.com
MAP130 AC-DC Series Data Sheet
OVERALL SIZE: 8.50" x 4.50" x 2.00" (215.9mm x 114.3mm x 50.8mm) WEIGHT: 2.5 lb (1.13 kg)
INPUT & OUTPUT CONNECTIONS: 6-32 SCREW WIRE CLAMPS ON 0.312" (7.9mm) CENTERS, 0.045" (1.1mm) SQUARE PINS ON 0.156" (3.96mm) CENTERS; MATES WITH MOLEX SERIES 2139, 6442, & 41695 POWER FAIL CONNECTIONS, J2: CHASSIS: 0.035" (0.89mm) SQUARE PINS ON 0.100" (2.54mm) CENTERS; MATES WITH MOLEX SERIES 2695 & 6471 0.090" (2.286mm) ALUMINUM ALLOY WITH CLEAR FINISH
NUCLEAR AND MEDICAL APPLICATIONS - Power-One products are not designed, intended for use in, or authorized for use as critical components in life support systems, equipment used in hazardous environments, or nuclear control systems without the express written consent of the respective divisional president of Power-One, Inc. TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending on the date manufactured. Specifications are subject to change without notice.
MAY 13, 2005 revised to JUN 14, 2006
Page 4 of 4
www.power-one.com