0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
MPU200-4530

MPU200-4530

  • 厂商:

    POWER-ONE

  • 封装:

  • 描述:

    MPU200-4530 - Power Factor Correction (PFC) with a low-profile package designed to meet 1U height co...

  • 数据手册
  • 价格&库存
MPU200-4530 数据手册
MPU200/MDU200 Series Data Sheet Features • • • • • • • • • RoHS lead free solder and lead solder exempted products are available Power Factor Correction (PFC) meets EN61000-3-2 Same size, airflow, and construction as MPU150/MDU150 with over 33% more power Single-wire current sense on quad model outputs V1 and V2 Remote sense on quad model outputs V1 and V2 Current share and N+1 redundancy (standard on all models) Overtemperature, overload, and overvoltage protection Available with SAE mountings MDU200 models have 48VDC input Description The MPU200/MDU200 Series is based upon the proven architecture of the MPU150/MDU150 product line. The MPU products incorporate Power Factor Correction (PFC) with a low-profile package designed to meet 1U height constraints. In this series, 200W of continuous output power is provided with single or multiple output units suited for distributed power or central power applications. The series provides high current +3.3V and +5V on a single platform to support mixed-mode, high-speed digital circuitry. Power-One's dual-converter architecture combines high reliability with exceptional regulation. All multiple-output models feature remote sense on outputs V1 and V2 to provide independent compensation of output cable losses. Other standard features include independent current sharing on V1 and V2 quad-model outputs, thermal shutdown, and remote inhibit. Airflow of 300 linear feet per minute (LFM) is required to deliver the full power density of greater than 4.0 watts per cubic inch. The MDU200 Series provides the same benefits as the MPU200 Series, with a nominal 48 volt DC input. AC Input, Single-Output Model Selection MODEL OUTPUT VOLTAGE ADJUSTMENT RANGE MAXIMUM OUTPUT CURRENT (NOTE 2) 200W/225W PK WITH 300 LFM FORCED-AIR COOLING (NOTE 1) PEAK OUTPUT LINE CURRENT (NOTE 2) REGULATION LOAD REGULATION RIPPLE & NOISE %p-p (NOTE 3) INITIAL SETTING ACCURACY MPU200-1012 MPU200-1024 MPU200-1048 12V 24V 48V 11.6V to 16V 22.8V to 29.2V 45V to 56V 17.0A 8.35A 4.2A 19.0A 9.4A 4.7A 0.1% 0.1% 0.1% 1% 1% 1% 1% 1% 1% 11.97V to 12.03V 23.95V to 24.05V 47.9V to 48.1V AC Input, Multiple-Output Model Selection OUTPUT VOLTAGE ADJUSTMENT RANGE MAXIMUM OUTPUT CURRENT (NOTE 2) 200W WITH 300 LFM FORCED-AIR COOLING (NOTE 1) ISOLATED V3 AND V4 CAN BE USED AS POSITIVE OR NEGATIVE OUTPUTS MODEL LINE REGULATION LOAD REGULATION RIPPLE & NOISE %Pk-Pk (NOTE 3) INITIAL SETTING ACCURACY +5V 5.0V to 5.5V 30A (Note 4) 0.4% 1% +3.3V 3.15V to 3.60V 15A (Note 4) 0.6% 1.5% MPU200-4530 12V 10.8V to 13.2V 8A (Note 5) 0.4% 10% 12V 10.8V to 13.2V 4A (Note 5) 0.4% 10% NOTES: 1) This product is not rated for convection applications. 2) Output currents ratings are expressed with 300 LFM forced air. 3) Maximum peak-to-peak noise expressed as a percentage of output voltage, 20 MHz bandwidth. 4) Total current for V1 and V2 is not to exceed 35A. 5) Total power on V3 and V4 is not to exceed 100W. 1% 1.5% 1% 1% 4.98V to 5.02V 3.28V to 3.32V 11.94V to 12.06V 11.60V to 12.40V Ordering Information: OPTIONS SUFFIXES TO ADD TO PART NUMBER Metric Mounting Isolation Diode Add “M” as a suffix to the model number to order chassis with M3 x 0.7 mounting inserts. Consult factory for availability. Offered on single-output models. Add “D” to the part number suffix if an isolation diode is needed. Consult factory for availability. RoHS lead solder exemption RoHS compliant for all 6 substances No RoHS suffix character required. Add “G” as the last character of the part number. JUL 14, 2006 revised to JUL 24, 2006 Page 1 of 6 www.power-one.com MPU200/MDU200 Series Data Sheet DC Input, Single Output Model Selection MODEL OUTPUT VOLTAGE ADJUSTMENT RANGE 200W WITH 300 LFM FORCED-AIR COOLING (NOTE 1) LINE REGULATION LOAD REGULATION RIPPLE & NOISE %Pk-Pk (NOTE 3) INITIAL SETTING ACCURACY MAXIMUM OUTPUT PEAK OUTPUT CURRENT (NOTE 2) CURRENT (NOTE 2) MDU200-1012G MDU200-1024G (NOTE 4) MDU200-1048G 12V 24V 48V 11.6V to 16V 22.8V to 29.2V 45V to 56V 17.0A 8.35A 4.2A 19.0A 9.4A 4.7A 0.1% 0.1% 0.1% 1% 1% 1% 1% 1% 1% 11.97V to 12.03V 23.95V to 24.05V 47.9V to 48.1V Isolation Diode Option - Offered on single-output models. Add “D” at the end of the part number if an isolation diode is needed. MPU200 Input Specifications PARAMETER Input Voltage - AC Input Frequency Hold-up Time Input Current Input Protection Inrush Surge Current Power Factor Operating Frequency CONDITIONS/DESCRIPTION Continuous input range. AC input. After last AC line peak at 200 watts 85 VAC at full rated load. Non-user serviceable internally located AC input line fuse. Internally limited by thermistor. Vin = 230 VAC, one cycle, 25°C. Per EN61000-3-2. Switching frequency of main output transformer. Switching frequency of secondary transformer. Switching frequency of Power Factor Correction circuit. MIN 85 47 15 NOM MAX 264 63 4.0 35 0.95 100 65 60 120 90 UNITS VAC Hz ms ARMS APK W/VA kHz MDU200 Input Specifications PARAMETER Input Voltage - DC Brown Out Protection Hold-up Time Input Current Input Protection Inrush Surge Current Operating Frequency CONDITIONS/DESCRIPTION Continuous input range. Lowest DC input voltage that regulation is maintained with full rated loads. At 200 watts, over DC input range. 36 VDC at full rated load. Non-user serviceable internally located AC input line fuse. Consult factory. Switching frequency of main output transformer. Switching frequency of secondary transformer. MIN 36 34 15 NOM MAX 75 UNITS VDC VDC ms ARMS 8.35 100 70 kHz NOTES:1) This product is not rated for convection applications. 2) Output currents ratings are expressed with 300 LFM forced air. 3) Maximum peak-to-peak noise expressed as a percentage of output voltage, 20 MHz bandwidth. 4) Derating is required on output voltages above 27VDC. Consult factory. JUL 14, 2006 revised to JUL 24, 2006 Page 2 of 6 www.power-one.com MPU200/MDU200 Series Data Sheet Output Specifications PARAMETER Efficiency Minimum Load, V1 CONDITIONS/DESCRIPTION MIN NOM MAX Full Rated Load, 110 VAC (MPU) or 48VDC (MDU). Varies with distribution of loads among outputs. 65 75 Minimum load required to maintain regulation on, V2 at maximum load. Quad output model V1 3 Minimum load required on single output models. Single output models V1 0 Minimum load required to maintain regulation on Quad output model V3 0.3 V4 at maximum load. Full load, 20 MHz bandwidth. See Model Selection Charts Output voltage overshoot/undershoot at turn-on. 5 Varies by output. Total regulation includes: line changes over the specified. See Model Selection Charts input range, changes in load starting at 20% load and changing to 100% load. Recovery time, to within 1% of initial set point due to a 50-100% load change, 500 5% max. deviation. Time required for initial output voltage stabilization. 2 Time required for output voltage to rise from 10% to 90%. MPU200 50 MDU200 80 UNITS % A A % Minimum Load, V3 Ripple and Noise Overshoot / Undershoot Regulation Transient Response Turn-on Delay Turn-on Rise Time μs s ms Interface Signals and Internal Protection PARAMETER Overvoltage Protection CONDITIONS/DESCRIPTION Latch style overvoltage protection. MIN NOM MAX 4.2 6.4 19 20.5 38.0 62.7 UNITS MPU200-4530 3.3V output 3.8 MPU200-4530 5V output 6.0 MPU200-4530 12V output 14 MDU200/MPU200-1012 V1 17.0 MDU200/MPU200-1024 V1 32.0 MDU200/MPU200-1048 V1 58.0 Fully protected against output overload and short circuit. Automatic recovery upon removal of overload condition. System shutdown due to excessive internal temperature, automatic reset. TTL compatible signal available for V1. Internal pull-up resistor is 475 . 3.3V Signal is high when output is above the specified limits. Signal shall 5V remain low for 20 milliseconds following loss of Output Good. MDU200/MPU200-1012 12V MDU200/MPU200-1024 24V MDU200/MPU200-1048 48V TTL compatible logic signal. Time before regulation dropout due to loss of input power. May be used as independent PSOK signal in redundant applications. Accuracy of shared current with up to 6 parallel units. Single wire current share on V1 and V2 with return via -Sense return. Available on V1 and V2. Total voltage compensation for cable losses with respect to the main output. Output voltage is inhibited by application of an external high (5V) signal. 3.16 4.75 10.5 21.5 43.0 5 10 500 V Overload Protection Overtemperature Protection Output Good Signal (Transision from Low to High) 3.25 4.95 11.9 23.5 47.0 V Input Power Fail Warning Current Share Remote Sense Inhibit ms % mV JUL 14, 2006 revised to JUL 24, 2006 Page 3 of 6 www.power-one.com MPU200/MDU200 Series Data Sheet Safety, Regulatory, and EMI Specifications PARAMETER Agency Approvals Dielectric Withstand Voltage Electromagnetic Interference ESD Susceptibility Radiated Susceptibility EFT/Burst Input Transient Protection CONDITIONS/DESCRIPTION UL60950,CSA 22.2 NO. 60950, and EN60950-1 (TÜV). Input to output per EN60950. FCC CFR title 47 Part 15 Sub-Part B - Conducted. EN55022 / CISPR 22 Conducted. Per EN61000-4-2, level 4. Per EN61000-4-3, level 3. Per EN61000-4-4, level 3. Per EN61000-4-5, class 3. MIN (Approved) MPU200 MDU200 2600 1414 B B 8 10 ±2 1 2 0.5 0.5 10 MPU200 Quad Output Model MPU200 Single Output Models MDU200 at 72 VDC (Not required by EN60950) 2.2 1.7 N/A VDC Class kV V/M kV kV MV mA NOM MAX UNITS MPU200: MPU200: MDU200: MDU200: Line to Line Line to Ground Line to Line Line to Ground Insulation Resistance Leakage Current Input to output. Per EN60950. Environmental Specifications PARAMETER Altitude Operating Temperature Derate linearly above 50°C by 2.5% per °C. Storage Temperature Temperature Coefficient Relative Humidity Shock Vibration 0°C to 70°C (after 15 minute warm-up). Non-Condensing. Peak acceleration. Random vibration, 10Hz to 2kHz, 3 axis. CONDITIONS/DESCRIPTION Operating. Non-Operating. At 100% load At 50% load MIN NOM MAX 10k 40k 50 70 85 ±0.05 95 20 6 UNITS ASL Ft. ASL Ft. °C °C °C %/°C %RH GPK GRMS 0 0 -55 ±0.02 5 Options DESCRIPTION Metric Mounting Isolation Diode NOTES Add “M” as a suffix to the model number to order chassis with M3 x 0.7 mounting inserts. Consult factory for availability. Offered on single-output models. Add “D” to the part number suffix if an isolation diode is needed. Consult factory for availability. JUL 14, 2006 revised to JUL 24, 2006 Page 4 of 6 www.power-one.com MPU200/MDU200 Series Data Sheet Overall Size: 8.00" x 4.20" x 1.50" (203.2mm x 106.7mm x 38.1mm) Weight: 2.0 lb (0.89 kg) SINGLE OUTPUT OUTPUTS: 8-32 SCREW CONNECTIONS (4PL) +V1 RTN INTERFACE CONNECTIONS (J300) MDU200 DC INPUT J1 +5 +4 3 2 1 V1,V. ADJ. S PIN 10. +S, V1 9. -S, V1 8. CURRENT SHARE, V1 7. NO CONNECTION 6. NO CONNECTION 5. NO CONNECTION 4. OUTPUT GOOD, V1 3. POWER FAIL WARNING 2. INHIBIT 1. SIGNAL GROUND MPU200 J1 AC L1 INPUT N3 5 MOLEX SERIES 5268-NA, P/N: 22-05-7105, PINS ON 2.50mm CENTERS. MATES WITH MOLEX: HOUSING SERIES 5264-N, P/N: 50-37-5103 (&) PINS SERIES 5263, P/N: 80-70-1040 (LOOSE) 3 TBD NOTE: MAX. LEAD PROTRUSION IS 0.0625" (1.588mm) ON THE FOUR BOTTOM MOUNTING HOLES. MAX. LEAD PROTRUSION OF 0.25" (6.25mm) IS ACCEPTABLE ON THE FOUR SIDE MOUNTING HOLES. CONNECTOR J1 J300 MOLEX SERIES 41695 41695 2139 5264-N HOUSING 09-50-8051 09-50-8051 09-50-3051 50-37-5103 PIN PINS PINS WIRE SERIES (LOOSE) (CHAIN) GAUGE 6838 08-50-0189 08-50-0187 18-20AWG 2478 08-50-0106 08-50-0105 18-20AWG 2478 08-50-0106 08-50-0105 18-20AWG 5263 08-70-1040 08-70-1039 22-28AWG CHASSIS: 0.063" (1.6mm) ALUMINUM ALLOY, WITH CLEAR FINISH JUL 14, 2006 revised to JUL 24, 2006 Page 5 of 6 www.power-one.com MPU200/MDU200 Series Data Sheet Overall Size: 8.00" x 4.20" x 1.50" (203.2mm x 106.7mm x 38.1mm) Weight: 2.0 lb (0.89 kg) 3 TBD NOTE: MAX. LEAD PROTRUSION IS 0.0625" (1.588mm) ON THE FOUR BOTTOM MOUNTING HOLES. MAX. LEAD PROTRUSION OF 0.25" (6.25mm) IS ACCEPTABLE ON THE FOUR SIDE MOUNTING HOLES. CONNECTOR J1 (ALL MODELS) J2 (TRIPLE OUTPUT) J3 (TRIPLE OUTPUT) J3 (QUAD OUTPUT) J300 MOLEX SERIES 41695 41695 2139 5051-N 5051-N 41695 41695 2139 41695 41695 2139 5264-N HOUSING 09-50-8051 09-50-8051 09-50-3051 22-01-1022 22-01-1022 09-50-8021 09-50-8021 09-50-3021 09-50-8061 09-50-8061 09-50-3061 50-37-5103 PIN SERIES 6838 2478 2478 2759 2759 6838 2478 2478 6838 2478 2478 5263 PINS (LOOSE) 08-50-0189 08-50-0106 08-50-0106 08-50-0114 08-65-0805 08-50-0189 08-50-0106 08-50-0106 08-50-0189 08-50-0106 08-50-0106 08-70-1040 PINS (CHAIN) 08-50-0187 08-50-0105 08-50-0105 08-50-0113 08-65-0804 08-50-0187 08-50-0105 08-50-0105 08-50-0187 08-50-0105 08-50-0105 08-70-1039 WIRE GAUGE 18-20AWG 18-20AWG 18-20AWG 22-30AWG 22-30AWG 18-20AWG 18-20AWG 18-20AWG 18-20AWG 18-20AWG 18-20AWG 22-28AWG CHASSIS: 0.063" (1.6mm) ALUMINUM ALLOY, WITH CLEAR FINISH NUCLEAR AND MEDICAL APPLICATIONS - Power-One products are not designed, intended for use in, or authorized for use as critical components in life support systems, equipment used in hazardous environments, or nuclear control systems without the express written consent of the respective divisional president of Power-One, Inc. TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending on the date manufactured. Specifications are subject to change without notice. JUL 14, 2006 revised to JUL 24, 2006 Page 6 of 6 www.power-one.com
MPU200-4530 价格&库存

很抱歉,暂时无法提供与“MPU200-4530”相匹配的价格&库存,您可以联系我们找货

免费人工找货