NET1 AC-DC Series Data Sheet
Features • Currents over 100 Amps • Fits 1U chassis height constraints • No minimum load requirement • Current-share capabilities on all outputs • Patented high-efficiency design • Meets European power factor requirements • Excellent load transient response
Description Designed to meet the stringent requirements of today’s high-speed datacom and telecom circuitry, Power-One’s NET1 Series is an excellent compact power solution for low-voltage, high-current applications. The NET1’s high efficiency is achieved through the use of synchronous rectification and a newly-patented “Soft Transition Forward Converter”. The NET1’s rectification method lowers output losses, reduces system cooling requirements (allowing greater power in a smaller package), and eliminates minimum-load requirements. Advanced surface-mount design and packing technology reduce the NET1’s height to 1.35” (34.3mm) to fit in 1U applications. NET1’s high-performance active power factor circuitry meets EN61000-3-2 requirements for compliance with European Power Line Harmonic Requirements for 2001. A multifunctional output terminal allows connection to #8 ring lugs, 0.25” quick disconnects, cable connectors, and PCB-mounted connectors.
Multiple-Output Model Selection – 240W WITH 300 LFM FORCED AIR COOLING
MODEL OUTPUT VOLTAGE ADJUSTMENT RANGE OUTPUT CURRENT (NOTE 1) LINE REGULATION LOAD REGULATION RIPPLE & NOISE Pk-Pk (NOTE 2) INITIAL SETTING ACCURACY
+3.3V NET1-4350 +12V +12V +5V +3.3V NET1-4230 +5V +12V +2.5V +3.3V NET1-4130 +5V +12V +1.8V +1.8V NET1-4112 +12V +12V +1.5V
+0.5V FIXED FIXED +0.5V +0.5V FIXED FIXED +0.5V +0.5V FIXED FIXED +0.5V +0.5V FIXED FIXED +0.5V
50A 4A 4A 30A 50A 5A 4A 50A 50A 5A 4A 50A 50A 4A 4A 50A
0.2% 0.2% 0.2% 0.2% 0.2% 0.2% 0.2% 0.2% 0.2% 0.2% 0.2% 0.2% 0.2% 0.2% 0.2% 0.2%
1% 3% 3% 1% 1% 3% 3% 1% 1% 3% 3% 1% 1% 3% 3% 1%
50mV 120mV 120mV 50mV 50mV 50mV 120mV 50mV 50mV 50mV 120mV 50mV 50mV 120mV 120mV 50mV
± 30mV ± 100mV ± 100mV ± 50mV ± 20mV ± 50mV ± 100mV ± 20mV ± 30mV ± 50mV ± 100mV ± 20mV ± 20mV ± 100mV ± 100mV ± 20mV
NOTES: 1) Output currents ratings are expressed with 300 LFM forced air @ 18 CFM. 2) Maximum peak-to-peak noise for a 20 MHz bandwidth.
Model numbers highlighted in yellow or shaded are not recommended for new designs.
MAY 18, 2005 revised to APR 05, 2006
Page 1 of 4
www.power-one.com
NET1 AC-DC Series Data Sheet
Input Specifications
PARAMETER CONDITIONS/DESCRIPTION MIN TYP MAX UNITS
Input Voltage - AC Input Frequency Hold-up Time Input Current Input Protection Inrush Surge Current Power Factor
Continuous input range. AC input. After last AC line peak at 240 watts. 85 VAC at full rated load. Non-user serviceable internally located AC input line fuse. Internally limited by thermistor. Vin = 220 VAC, one cycle, 25 °C. Per EN61000-3-2.
85 47 20 4.0
264 63
VAC Hz ms ARMS APK W/VA
35 0.95
Output Specifications
PARAMETER CONDITIONS/DESCRIPTION MIN TYP MAX UNITS
Efficiency Ripple and Noise Output Power Overshoot / Undershoot Regulation Transient Response Turn-on Delay Turn-on Rise Time
Full Rated Load, 110 VAC. Varies with distribution of loads among outputs. Full load, 20 MHz bandwidth. With 300 LFM forced air cooling. (Note 1) Output voltage overshoot/undershoot at turn-on. Varies by output. Total regulation includes: line changes over the specified. input range, changes in load starting at 20% load and changing to 100% load. Recovery time, to within 1% of initial set point due to a 10-100% load change, 1% max. deviation. Time required for initial output voltage stabilization. Time required for output voltage to rise from 10% to 90%.
75 See Model Selection Charts 240 0 See Model Selection Charts 500 2 20
% Watts %
µs Sec ms
Interface Signals and Internal Protection
PARAMETER CONDITIONS/DESCRIPTION MIN TYP MAX UNITS
Overvoltage Protection
Overload Protection Overtemperature Protection Output Good
Input Power Fail Warning
Current Share
Remote Sense
Overvoltage protection on all outputs. 120 Unit latches off when overvoltage is detected. AC input must be recycled to reset. Fully protected against output overload and short circuit. Automatic recovery upon removal of overload condition. All outputs are individually current limited. System shutdown due to excessive internal temperature, automatic reset. Signal indicates output good when at a TTL high state. If any of the outputs are 14% of the nominal output voltage, then this signal will make a transition to a TTL low state. Pull-up resistance is 1k to 5V Vcc and minimum sink current is 50 mA. Maximum voltage at low state is 0.5 V. TTL-compatible signal. Pull-up resistance is 1k to 5V Vcc and minimum sink current is 50 mA. Maximum voltage at low state is 0.5 V. Time before regulation 5 dropout due to loss of input power. May be used as independent PSOK signal in redundant applications. Available on all outputs. Accuracy of shared current with up to 6 parallel units. Single wire current share. Isolation diodes need to be added for parallel configurations with or without redundancy. Available on all outputs. Total voltage compensation for cable losses with respect to the main output.
140
%
ms
10
%
500
mV
NOTES: 1) Output current ratings are expressed with 300 LFM forced air @ 18 CFM.
MAY 18, 2005 revised to APR 05, 2006
Page 2 of 4
www.power-one.com
NET1 AC-DC Series Data Sheet
Safety, Regulatory, and EMI Specifications
PARAMETER CONDITIONS/DESCRIPTION MIN TYP MAX UNITS
Agency Approvals
Dielectric Withstand Voltage Electromagnetic Interference ESD Susceptibility Radiated Susceptibility EFT/Burst Input Transient Protection Insulation Resistance
UL60950. CSA 22.2 NO. 60950-00 (cUL). EN60950 (TÜV). Input to output per EN60950. FCC CFR title 47 Part 15 Sub-Part B - Conducted. EN55022 / CISPR 22 Conducted. Per EN61000-4-2, level 4. Per EN61000-4-3, level 3. Per EN61000-4-4, level 3. Per EN61000-4-5, class 3. Input to output.
Approved 2600 B B 8 10 ±2 1 2 10 VDC Class kV V/M kV kV M
Line to Line Line to Ground
Environmental Specifications
PARAMETER CONDITIONS/DESCRIPTION MIN TYP MAX UNITS
Altitude Operating Temperature Storage Temperature Temperature Coefficient Relative Humidity Shock Vibration
Operating. Non-Operating. At 100% load 0 °C to 70 °C (after 15-minute warmup). Non-Condensing. Peak acceleration. Random vibration, 10 Hz to 2 kHz, 3 axis. 0 -40 ±0.02 5
10k 40k 50 85 ±0.05 95 20 6
ASL Ft. ASL Ft. °C °C %/°C %RH GPK GRMS
Mechanical
DESCRIPTION NOTES SIZE IMPACT
Metric Mounting Size
M4 x 0.7 mounting inserts: 2 mounting surfaces 7.00" x 4.50" x 1.35" (177.8mm x 114.3mm x 34.3mm)
NUCLEAR AND MEDICAL APPLICATIONS - Power-One products are not designed, intended for use in, or authorized for use as critical components in life support systems, equipment used in hazardous environments, or nuclear control systems without the express written consent of the respective divisional president of Power-One, Inc. TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending on the date manufactured. Specifications are subject to change without notice.
MAY 18, 2005 revised to APR 05, 2006
Page 3 of 4
www.power-one.com
NET1 AC-DC Series Data Sheet
L
N
G
TERMINAL END, TOP VIEW
AC INPUT END PN: MOLEX 09-74-1051M #26 BOTTOM (MOUNTING SURFACE) 8-32 THREADED INSERT AND PHILLIPS SCREW 4PL
J1
C D E
0.000
A B
(J1 AC INPUT)
R G H J
4PL
USER MOUNTING POINTS, 4PL M4x0.7 FLUSH NUT MAXIMUM PENETRATION 0.15" THROUGH POWER SUPPLY MOUNTING SURFACE AIR FLOW
F
K L M N P V3 V2 V1 -+
SIDE VIEW
WX
PROVIDE CLEARANCE FOR AIR EXHAUST FROM THESE AIR VENTS, BOTH SIDES. SCREW TERMINAL (MOUNTING SURFACE) 2PL
BOTTOM VIEW
0.000
V4 -+
(4 PL)
Q
0.000 BOTTOM 0.000
TERMINAL END, FRONT VIEW
ZA
2PL
Y
POS 3PL
NEG 3PL
POS NEG 3PL 3PL
J501 9
Vo1 +R.S. Vo1 -R.S. Vo4 +R.S. Vo4 -R.S. Vo1 C.Shr Vo4 C.Shr POWER FAIL POWER GOOD INHIBIT
V U T S
0.000 HIGH CURRENT OUTPUTS: 8-32 SCREW CONNECTIONS, 4PL OR 0.250" BY 0.032" QUICK DISCONNECTS, 3PL OR WICKMANN CONNECTORS (9100070000 AND 9100080000), 2 EA OR EQUIVALENT.
Z P
0.000
J701 1
Vo3 +R.S. Vo3 -R.S. Vo3 C.Shr Vo3 Vo3 Vo3 Vo3 RTN Vo3 RTN Vo3 RTN
J801 1
Vo2 +R.S. Vo2 -R.S. Vo2 C.Shr Vo2 Vo2 Vo2 Vo2 RTN Vo2 RTN Vo2 RTN
1
OVERALL SIZE: 7.00" (177.8mm) x 4.50" (114.3mm) x 1.35" (34.3mm) WEIGHT: 1.9 lb (0.86 kg) TOLERANCES: .XX = 0.03" (0.8mm)
9
9
Callout A B C D E F G H J K L M
Inches 4.006 3.445 1.006 0.445 0.502 0.23 0.56 0.93 1.26 3.23 3.56 3.93
Millimeters 101.75 87.50 25.55 11.30 12.75 5.8 14.2 23.6 32.0 82.0 90.4 99.8
Callout N P Q R S T U V W X Y Z ZA
Inches 4.26 4.500 1.14 0.211 1.350 1.125 0.906 0.536 7.000 6.500 0.250 3.750 0.400
Millimeters 108.2 114.30 29.0 5.36 34.29 28.58 23.01 13.61 177.8 165.10 6.35 95.25 10.20
NET1 Connectors
J501 Housing Pins J701 Housing Pins J801 Housing Pins 50-37-5093 08-70-1039 50-37-5093 08-70-1039 50-37-5093 08-70-1039
Note: Part numbers are MOLEX; equivalents are acceptable.
MAY 18, 2005 revised to APR 05, 2006
Page 4 of 4
www.power-one.com