NET1 SERIES
Designed to meet the stringent requirements of today’s high-speed datacom and telecom circuitry, Power-One’s NET1 series is an excellent compact power solution for low-voltage, high-current applications. The NET1’s high efficiency is achieved through the use of synchronous rectification and a newly-patented “Soft Transition Forward Converter”. The NET1’s rectification method lowers output losses, reduces system cooling requirements (allowing greater power in a smaller package), and eliminates minimum load requirements.
Advanced Produc t Release
Advanced surface-mount design and packing technology reduce the NET1’s height to 1.35” (34.3mm) to fit in 1U applications. NET1’s high-performance active power factor circuitry meets EN61000-3-2 requirements for compliance with European Power Line Harmonic Requirements for 2001. A multifunctional output terminal allows connection to #8 ring lugs, 0.25” quick disconnects, cable connectors, and PCB-mounted connectors.
FEATURES • Currents Over 100 Amps • Fits 1U Chassis Height Constraints • No Minimum Load Requirement • Current Share Capabilities on All Outputs • Patented High-Efficiency Design • Meets European Power Factor Requirements for 2001 • Excellent Load Transient Response
MULTIPLE OUTPUT MODEL SELECTION CHART – 240W WITH 300 LFM FORCED AIR COOLING
MODEL OUTPUT VOLTAGE ADJUSTMENT RANGE OUTPUT CURRENT (NOTE 1) LINE REGULATION LOAD REGULATION RIPPLE & NOISE %Pk-Pk (NOTE 2) INITIAL SETTING ACCURACY
NET1-4325
NET1-4130
NET1-4112
+3.3V +2.5V +5V +12V +1.8V +3.3V +5V +12V +1.8V +1.65V +5V +12V
+0.5V +0.5V FIXED FIXED +0.5V +0.5V FIXED FIXED +0.5V +0.5V FIXED FIXED
50A 50A 5A 4A 50A 50A 5A 4A 50A 50A 5A 4A
0.2% 0.2% 0.2% 0.2% 0.2% 0.2% 0.2% 0.2% 0.2% 0.2% 0.2% 0.2%
1% 1% 3% 3% 1% 1% 3% 3% 1% 1% 3% 3%
1% or 50mV 1% or 50mV 1% or 50mV 1% or 50mV 1% or 50mV 1% or 50mV 1% or 50mV 1% or 50mV 1% or 50mV 1% or 50mV 1% or 50mV 1% or 50mV
± 30mV ± 30mV ± 30mV ± 100mV ± 20mV ± 30mV ± 30mV ± 100mV ± 20mV ± 30mV ± 30mV ± 100mV
NOTES: 1) Output currents ratings are expressed with 300 LFM forced air. 2) Maximum peak-to-peak noise expressed as a percentage of output voltage, 20 MHz bandwidth.
INPUT SPECIFICATIONS
PARAMETER CONDITIONS/DESCRIPTION MIN TYP MAX UNITS
Input Voltage - AC Input Frequency Hold-up Time Input Current Input Protection Inrush Surge Current Power Factor
Continuous input range. AC input. After last AC line peak at 240 watts. 85 VAC at full rated load. Non-user serviceable internally located AC input line fuse. Internally limited by thermistor. Vin = 220 VAC, one cycle, 25°C. Per EN61000-3-2.
85 47 20 4.0
264 63
VAC Hz mS ARMS APK W/VA
35 0.95
Rev. 11/2000
1
NET1 SERIES
OUTPUT SPECIFICATIONS
PARAMETER CONDITIONS/DESCRIPTION
Advanced Produc t Release
MIN TYP MAX UNITS
Efficiency Ripple and Noise Output Power Overshoot / Undershoot Regulation Transient Response Turn-on Delay Turn-on Rise Time
Full Rated Load, 110 VAC. Varies with distribution of loads among outputs. Full load, 20 MHz bandwidth. With 300 LFM forced air cooling. (Note 1) Output voltage overshoot/undershoot at turn-on. Varies by output. Total regulation includes: line changes over the specified. input range, changes in load starting at 20% load and changing to 100% load. Recovery time, to within 1% of initial set point due to a 10-100% load change, 1% max. deviation. Time required for initial output voltage stabilization. Time required for output voltage to rise from 10% to 90%.
80 See Model Selection Charts 240 0 See Model Selection Charts 500 2 20
% Watts %
µS Sec mS
INTERFACE SIGNALS AND INTERNAL PROTECTION
PARAMETER CONDITIONS/DESCRIPTION MIN TYP MAX UNITS
Overvoltage Protection
Overload Protection Overtemperature Protection Output Good Input Power Fail Warning Current Share Remote Sense
Overvoltage protection on all outputs. Maximum + 0.5V Unit latches off when overvoltage is detected. AC input must be recycled to reset. Fully protected against output overload and short circuit. Automatic recovery upon removal of overload condition. System shutdown due to excessive internal temperature, automatic reset. Open collector global Output Good signal. The signal activates when any of the outputs drop below 5%. Open collector signal. Time before regulation dropout due to loss of input 5 power. May be used as independent PSOK signal in redundant applications. Available on all outputs. Accuracy of shared current with up to 6 parallel units. 10 Single wire current share. Available on all outputs. Total voltage compensation for cable losses with 500 respect to the main output.
mS % mV
SAFETY, REGULATORY, AND EMI SPECIFICATIONS
PARAMETER CONDITIONS/DESCRIPTION MIN TYP MAX UNITS
Agency Approvals
Dielectric Withstand Voltage Electromagnetic Interference ESD Susceptibility Radiated Susceptibility EFT/Burst Input Transient Protection Insulation Resistance
UL1950. CSA 22.2 NO. 234/950. EN60950 (TÜV). Input to output per EN60950. FCC CFR title 47 Part 15 Sub-Part B - Conducted. EN55022 / CISPR 22 Conducted. Per EN61000-4-2, level 4. Per EN61000-4-3, level 3. Per EN61000-4-4, level 3. Per EN61000-4-5, class 3. Input to output.
Approved 2600 B B 8 10 ±2 1 2 10 VDC Class kV V/M kV kV M
Line to Line Line to Ground
NUCLEAR AND MEDICAL APPLICATIONS Power-One products are not authorized for use as critical components in life support systems, equipment used in hazardous environments, or nuclear control systems without the express written consent of the President of Power-One, Inc. TECHNICAL REVISIONS The appearance of products, including safety agency certifications pictured on labels, may change depending on the date manufactured. Specifications are subject to change without notice.
2
NET1 SERIES
ENVIRONMENTAL SPECIFICATIONS
PARAMETER CONDITIONS/DESCRIPTION
Advanced Produc t Release
MIN TYP MAX UNITS
Altitude Operating Temperature Storage Temperature Temperature Coefficient Relative Humidity Shock Vibration
Operating. Non-Operating. At 100% load 0°C to 70°C (after 15-minute warmup). Non-Condensing. Peak acceleration. Random vibration, 10 Hz to 2 kHz, 3 axis. 0 -40 ±0.02 5
10k 40k 50 85 ±0.05 95 20 6
ASL Ft. ASL Ft. °C °C %/°C %RH GPK GRMS
MECHANICAL
DESCRIPTION NOTES SIZE IMPACT
Metric Mounting Size
M4 x 0.7 mounting inserts: 2 mounting surfaces 7.00" x 4.50" x 1.35" (177.8mm x 114.3mm x 34.3mm)
3
很抱歉,暂时无法提供与“NET1”相匹配的价格&库存,您可以联系我们找货