NET2-4350 数据手册
NET2 AC-DC Series Data Sheet Advance Product Release Features • 400W output power with currents over 100 Amps • 85% efficiency (typical) • 5-output construction • Isolated V2 and V3 outputs • Standby output of 5V @ 2A • Fits 1U chassis height constraints • No minimum load requirement • Active current-share capabilities with redundant capabilities on the four main outputs • Patented high-efficiency design • Meets European power factor requirements • Excellent load transient response • Redundancy without use of ORing diode Description Designed to meet the stringent requirements of today’s high-speed circuitry, Power-One’s NET2 Series is an excellent compact power solution for low-voltage, high-current applications. The NET2’s high efficiency is achieved through the use of synchronous rectification and a newly-patented “Soft Transition Forward Converter”. The NET2’s rectification method lowers output losses, reduces system cooling requirements (allowing greater power in a smaller package), and eliminates minimum-load requirements. Advanced surface-mount design and packing technology reduce the NET2’s height to 1.59” (40.3mm) to fit in 1U applications. NET2’s high-performance active power factor circuitry meets EN61000-3-2 requirements for compliance with European Power Line Harmonic Requirements for 2001. A multifunctional output terminal allows connection to #8 ring lugs, 0.25” quick disconnects, cable connectors, and PCB-mounted connectors. Multiple-Output Model Selection – 400W WITH 460 LFM FORCED-AIR COOLING MODEL OUTPUT VOLTAGE ADJUSTMENT RANGE OUTPUT CURRENT LINE REGULATION LOAD & CROSSREGULATION RIPPLE & NOISE Pk-Pk (NOTE 2) INITIAL SETTING ACCURACY (NOTE 3) V1 NET2-4350 (Note1) V2 V3 V4 V5 V1 NET2-4231 (Note1,4) V2 V3 V4 V5 +3.3V 12V 12V +5V +5.2VSB +3.3V 12V 1.8V +2.5V +5.2VSB +5%, -2% +5%, -5% +5%, -5% +5%, -2% FIXED +5%, -2% +5%, -5% +5%, -2% +5%, -2% FIXED 55A 5A 5A 40A 2A 55A 5A 15A 55A 2A 0.6% 0.5% 0.5% 0.5% 0.5% 0.6% 0.5% 0.6% 0.6% 0.5% 1% 1% 1% 1% 4% 1% 1% 1% 1% 4% 50mV 120mV 120mV 50mV 50mV 50mV 120mV 120mV 50mV 50mV +40mV, -10mV ± 70mV ± 70mV +50mV, -10mV ± 110mV +40mV, -10mV ± 70mV ± 70mV +30mV, -10mV ± 110mV NOTES: 1) V1 + V2, or V3 + V4 must not exceed 200W. 2) Maximum peak-to-peak noise for a 20 MHz bandwidth. 3) Initial set points: V1 @ 40A, V2 @ 4A, V3 @ 4A, V4 @ 30A, and V5 @ 1A. 4) Consult factory for availability. APR 19, 2005 revised to JUN 28, 2006 Page 1 of 5 www.power-one.com NET2 AC-DC Series Data Sheet Input Specifications PARAMETER CONDITIONS/DESCRIPTION MIN TYP MAX UNITS Input Voltage - AC Input Frequency Hold-up Time Input Current Input Protection Inrush Surge Current Power Factor Continuous input range. AC input. After last AC line peak at 400 watts. 85 VAC at full rated load. Non-user serviceable internally located AC input line fuse. Internally limited by thermistor. Vin = 220 VAC, one cycle, 25°C. Per EN61000-3-2 (Over the entire input range and above 60W load). 85 47 20 264 63 7.0 35 VAC Hz ms ARMS APK W/VA 0.95 Output Specifications PARAMETER CONDITIONS/DESCRIPTION MIN TYP MAX UNITS Efficiency Ripple and Noise Output Power Overshoot / Undershoot Regulation Transient Response Turn-on Delay Turn-on Rise Time Full Rated Load, 115 VAC. Varies with distribution of loads among outputs. 85 Full load, 20 MHz bandwidth. See Model Selection Charts With 460 LFM forced-air cooling (25 CFM through the power supply opening), V1+V2+V3+V4+V5: 400 V1+V2 or V3+V4: 200 Output voltage overshoot/undershoot at turn-on. 3.5 Varies by output. Regulation includes: line changes over the specified See Model Selection Charts input range and changes in load between 0% and 100% load. Recovery time, to within 1% of initial set point due to a 50% load change in V1/V4/V5: 1 the load range of 10 to 100%; 3.5% or 100mV deviation, whichever is greater. V2/V3 0.5 Time required for initial output voltage stabilization. 1.5 2 Time required for output voltage to rise from 10% to 90%. 20 % Watts % ms Sec ms Interface Signals and Internal Protection PARAMETER CONDITIONS/DESCRIPTION MIN TYP MAX UNITS Overvoltage Protection Overload Protection Overtemperature Protection Output Good Input Power Fail Warning Current Share Remote Sense Overvoltage protection on all outputs except V5. Unit latches off when overvoltage is detected. AC input must be recycled to reset. V5 is protected by a 6.2V ±5%, 2W Zener diode. Fully protected against output overload and short circuit. Automatic recovery upon removal of overload condition. All outputs are individually current limited. Power supply shuts down due to excessive internal overtemperature at the output converter’s primary switching transistors. Power supply resets automatically upon removal of the overtemperature cause. TTL-compatible global Output Good signal. The signal is active when any of the V1-V4 outputs drop >14% below nominal. Source impedance is 1k . Open collector signal. Time before regulation dropout due to loss of input power. May be used as independent PSOK signal in redundant applications. Available on all outputs except V5. Accuracy of shared current with up to two parallel units. Single wire current share is provided. For paralleling more than two units, consult factory. Available on all outputs except V5. Total voltage compensation for cable losses with respect to the main output. 120 140 % 5 10 ms % 500 mV APR 19, 2005 revised to JUN 28, 2006 Page 2 of 5 www.power-one.com NET2 AC-DC Series Data Sheet Safety, Regulatory, and EMI Specifications PARAMETER CONDITIONS/DESCRIPTION MIN TYP MAX UNITS Agency Approvals Dielectric Withstand Voltage Electromagnetic Interference ESD Susceptibility Radiated Susceptibility EFT/Burst Input Transient Protection Ground Leakage UL60950. CSA 22.2, NO. 60950-00 (cUL). EN60950-1 (TÜV). IEC60950-1 Input to output per EN60950. FCC CFR title 47 Part 15 Sub-Part B - Conducted. EN55022 / CISPR 22 Conducted. Per EN61000-4-2, level 4. Contact discharge: ±10% Air discharge: Per EN61000-4-3, level 3. Frequency 0.8 - 1.0 GHz, 80% AM @ 1 kHz Per EN61000-4-4, level 3. Per EN61000-4-5, class 3. UL60950/EN60950/CSA 6950-00 NET2-4350 Approved; NET2-4231 Pending NET2-4350 Approved; NET2-4231 Pending NET2-4350 Approved; NET2-4231 Pending NET2-4350 Approved; NET2-4231 Pending 2600 VDC B Class B 8 kV 10 10 V/M ±2 kV Line to Line 1 kV Line to Ground 2 @254VAC 1 mA Environmental Specifications PARAMETER CONDITIONS/DESCRIPTION MIN TYP MAX UNITS Altitude Operating Temperature Storage Temperature Temperature Coefficient Relative Humidity Shock Operating. Non-Operating. From 50°C to 70°C derate each output and total power to 50% of rating at 70°C. 0°C to 70°C (after 15-minute warmup). Non-Condensing. Operating: Half-sine, 10 ± 3ms duration; one positive and one negative shock in each of the three perpendicular axes for a total of 6 shocks. Non-Operating: Half-sine, 10 ± 3ms duration; one positive AND one negative shock in each of the three perpendicular axes for a total of 6 shocks. Operating: Logarithmic sweep, 1 octave/min 5-2000-5 Hz vertical, lateral, and longitudinal axes; 5-32 Hz, 0.02” double amplitude; 32-2000 Hz 2000-32 Hz 32-5 Hz double amplitude. Non-Operating: Random 1 hour/axis, vertical, lateral, and max longitudinal over 10-2000 Hz. At 100% load 0 -40 ± 0.02 5 10 10k 40k 50 85 ± 0.05 95 20 ASL Ft. ASL Ft. °C °C %/°C %RH GPK 30 40 GPK Vibration 1 1 Gpk Gpk 6.15 Grms Mechanical DESCRIPTION NOTES SIZE IMPACT Metric Mounting Chassis Size M3 x 0.5 mounting inserts: 3 mounting surfaces 8.25" x 4.50" x 1.59" (209.6mm x 114.3mm x 40.4mm) APR 19, 2005 revised to JUN 28, 2006 Page 3 of 5 www.power-one.com NET2 AC-DC Series Data Sheet Mechanical Drawing NOTE: METRIC DIMENSIONS ARE SHOWN IN BRACKETS M3 X 0.5 MOUNTING INSERTS (8) PLACES, 2 PL EACH SIDE, 4PL ON BOTTOM. 0.150" MAX PROTRUSION OF MOUNTING SCREWS INTO POWER SUPPLY. ± 0.020 1.588" (40.3) 0.700" (17.8) 0 0.900" (22.9) 8.250" (209.6) 0.331" (8.4) + 0.000 - 0.020 0.400" (10.2) 0.219" (5.6) M M 0.370" (9.4) 0 0.550" (14) 7.600" (193.0) 4.500" (114.3) 4.125" (104.8) M M 0.331" (8.4) 0.331" (8.4) BOTTOM VIEW 0.375" (9.5) 0 0 M M 0.250" (6.4) 8.000" (203.2) HIGH CURRENT OUTPUTS 0.25" QUICK DISCONNECT, 12 PL MAX OR #8 LUG 4PL, OR WICKMAN CONNECTOR PN: 9100080000 OR EQUIV, 4 PL 0.331" (8.4) 0 -1.100" (-27.9) M M - 0.900" (-22.9) 0 2.100" (53.3) 7.600" (193) NOTE: TOLERANCE ( .XXX = ± 0.010 UNLESS OTHERWISE SPECIFIED) APR 19, 2005 revised to JUN 28, 2006 Page 4 of 5 www.power-one.com NET2 AC-DC Series Data Sheet INPUT & OUTPUTS Vo4 adj Vo2 adj Vo1 adj Vo1 Vo1 RTN Vo2 O/P SEC.CNTL, Vo5 Vo3 O/P Vo4 Vo4 RTN Vo3 adj J6 J1 L N G P1 P4 Vo3 Inhibit Vo3 C.Shr. Vo3 -R.S. Vo3 +R.S. Vo3 RTN Vo3 RTN Vo3 Vo3 Vo1 +R.S. Vo1 -R.S. Vo4 +R.S. Vo4 -R.S. Vo1 C.Shr. Vo4 C.Shr. POWER FAIL POWER GOOD INHIBIT +Vo5 -Vo5 P2 Vo2 Inhibit Vo2 C.Shr. Vo2 -R.S. Vo2 +R.S. Vo2 RTN Vo2 RTN Vo2 Vo2 P5 P3 Vo3 OUTPUT PINOUT SEC.CNTL.BRD.PINOUT Vo2 OUTPUT PINOUT Connectors The NET2 uses #8-32 screw terminal and/or 0.25” faston connections for outputs 1 and 4, and Molex 5264-N Series connectors (50-37-5093) for auxiliary outputs and control signals. For the AC input, the NET2 uses a Molex 41694/2139 (09-50-3051) series connector. NET2-4350 NET2-4231 P1 Housing Pins P2 & P4 P3 & P5 Housing Pins Housing Pins 50-37-5113 08-70-1039 50-37-5043 08-70-1039 39-01-4041 39-00-0038 NOTE: Part numbers are MOLEX; equivalents are acceptable. NUCLEAR AND MEDICAL APPLICATIONS - Power-One products are not designed, intended for use in, or authorized for use as critical components in life support systems, equipment used in hazardous environments, or nuclear control systems without the express written consent of the respective divisional president of Power-One, Inc. TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending on the date manufactured. Specifications are subject to change without notice. APR 19, 2005 revised to JUN 28, 2006 Page 5 of 5 www.power-one.com
NET2-4350 价格&库存

很抱歉,暂时无法提供与“NET2-4350”相匹配的价格&库存,您可以联系我们找货

免费人工找货