QBC DC-DC Series Data Sheet
132-Watt Quarter-Brick Bus Converter
Features
•
•
•
•
•
•
•
•
•
•
•
•
•
Applications
•
•
•
•
Intermediate Bus architectures
Telecommunications equipment
LAN/WAN
Data processing
•
•
Cost-effective, single board design
Low profile – 11 mm height
Input/output isolation: 1500VDC
Basic insulation
High efficiency up to 91%
Start-up into high capacitive load
Low conducted and radiated EMI
Output overcurrent protection
Output overvoltage protection
Backdrive protection
Overtemperature protection
Remote sense
Remote on/off (primary referenced), positive or
negative logic
Adjustable output voltage from 9.6V to 13.2V
UL 1950 Recognition, CSA 22.2 No. 950-95
certification, TUV IEC950
Description
The QBC Series of high density bus converters convert a worldwide telecom bus voltage of 36 to 75VDC to a 12V
bus at 11A. The output is ideal for powering non-isolated, point-of-load converters such as synchronous buck
converters used commonly in Intermediate Bus Architectures.
The QBC is a highly efficient, cost-effective, low profile, single-output DC/DC converter in an industry-standard,
quarter-brick footprint. The standard feature set includes remote on/off, remote output voltage sensing, positive
output trim, input undervoltage lockout, and overtemperature shutdown with hysteresis.
Model Selection
Model
QBC11ZH-T
Input
Voltage
VDC
Input
Current, Max
ADC
Output
Voltage
Vout,
VDC
Output Rated
Current
I rated,
ADC
Output
Ripple/Noise,
36-75
4.5
12.0
11
125
mV p-p
(Typical)
Typical
Efficiency @
I rated, %
90
This product is intended for integration into end-use equipment. All the required procedures for CE marking of end-use equipment
should be followed.
REV. DEC 16, 2003
www.power-one.com
Page 1 of 7
QBC DC-DC Series Data Sheet
132-Watt Quarter-Brick Bus Converter
Absolute Maximum Ratings
Stresses in excess of the absolute maximum ratings may cause performance degradation, adversely effect longterm reliability, and cause permanent damage to the converter.
Parameter
Input Voltage
Operating Temperature
Conditions/Description
Continuous
Transient, 100 ms
PC Board Temperature
Min
Storage Temperature
Units
VDC
VDC
-40
Max
75
100
100
-40
125
°C
°C
Environmental and Mechanical Specifications
All specifications apply over specified input voltage, output load, and temperature range, unless otherwise noted.
Parameter
Shock
Sinusoidal Vibration
Weight
Water Washing
MTBF
Conditions/Description
(Half-sinewave, 6ms), 3 axes
GR-63-CORE, Section 5.4.2
Min
Standard process
Per Bellcore TR-NWT-000332
Nom
50
1
1.2/35
Yes
1,980
Max
Units
g
g
Oz/g
kHrs
Isolation Specifications
All specifications apply over specified input voltage, output load, and temperature range, unless otherwise noted.
Parameter
Insulation Safety Rating
Isolation Voltage
Isolation Resistance
Isolation Capacitance
Conditions/Description
Min
Input to Output
1500
10
Nom
Basic
Max
Units
VDC
MOhm
pF
1000
Input Specifications
All specifications apply over specified input voltage, output load, and temperature range, unless otherwise noted.
Parameter
Input Voltage
Turn-On Input Voltage
Turn-Off Input Voltage
Turn-On Time
Conditions/Description
Continuous
Ramping Up
Ramping Down
To Output Regulation Band
100% Resistive Load
Input Reflected Ripple Current
Inrush Transient
REV. DEC 16, 2003
Max
75
35
33
10
Units
VDC
VDC
VDC
ms
Full Load, 12µH source inductance
100
mA p-p
Vin=Vin.max
1
As
www.power-one.com
Min
36
33
31
Nom
48
5
Page 2 of 7
2
QBC DC-DC Series Data Sheet
132-Watt Quarter-Brick Bus Converter
Output Specifications
All specifications apply over specified input voltage, output load, and temperature range, unless otherwise noted.
Parameter
Conditions/Description
Min
Max
Units
Output Voltage Setpoint Accuracy
Vin=Vin.nom, Full Load
-2
Nom
2
%Vout
Output Current*
See selection chart for Irated
0
100
%Irated
Line Regulation
Vin.min to Vin.max, Irated
0.5
1
%Vout
Load Regulation
Vin=Vin.nom, 10% to 100%Irated
0.5
1
%Vout
Total Output Voltage Regulation
Over all input voltage, load, and
temperature conditions
5
%Vout
5
%Vout
-5
Remote Sense Headroom
Dynamic Regulation
Peak Deviation
Settling Time
50-100% load step change
600
200
to 2% error band
Admissible Load Capacitance
Irated, Nom Vin
Output Current Limit Threshold**
Vout≤0.97Vout.nom
115
Switching Frequency
mV
500
µs
6,800
µF
135
%Irated
425
kHz
Overvoltage Protection,
Non Latching
Over all input voltage and load
conditions
115
130
%Vout
Trim Range
Irated, Vin=Vnom
80
110
%Vout
* At Iout