QBS DC-DC Series Data Sheet
Features
•
•
•
•
•
•
•
High power density up to 120W
Open-frame packaging
100°C base plate operation
Water washable
Outputs from 2.5V to 15V
1500V isolation
Positive or negative enable logic
Description
QBS single output dc-dc converters provide up to 120 watts of output power in an industry-standard,
quarter-brick footprint. The QBS converters feature open-frame packaging, along with planar magnetics to provide
maximum useable power with minimal thermal constraints. The QBS is especially suited to telecom, networking, and
industrial applications, and is fully compatible with production board washing processes.
Technical Specifications
Input
Voltage Range
24 VDC Nominal
48 VDC Nominal
Input Reverse Voltage Protection
Efficiency vs. Load (48V Input)
18 - 36 VDC
36 - 75 VDC
Shunt Diode
90
85
80
QBS100ZG-ANT
Output
Setpoint Accuracy
Line Regulation Vin Min. - Vin Max., Iout Rated
Load Regulation Iout Min. - Iout Max., Vin Nom.
Remote Sense Headroom
Minimum Output Current
Dynamic Regulation, Loadstep
Pk Deviation
Settling Time
Voltage Trim Range
Short Circuit And Overcurrent Protection
Current Limit Threshold Range, % of Iout Rated
Short Circuit Current Limit
Range
UVP Trip Range
OVP/UVP Type
75
±1%
0.2% Vout
0.5% Vout
0.5 VDC
10 % lout Rated
25% Iout
4% Vout
500 m s
±10%
Shutdown
110 - 140%
200% IoutOVP Trip
115 - 140% Vout Nom.
70 - 90% Vout Nom.
Latching
EFF. (36v)
70
EFF. (48v)
EFF. (75v)
65
60
10
20
30
40
50
60
LOAD%
70
80
90
100
General
Turn-On Time
Remote Shutdown
Remote Shutdown Reference
Switching Frequency
Isolation
Input - Output
Input - Case
Output - Case
Temperature Coefficient
Case Temperature
Operating Range
Storage Range
Thermal Shutdown Range
Vibration, 3 Axes, 5 Min Each
MTBF† (Bellcore TR-NWT-000332)
Safety
Weight (Approx.)
30 ms
Positive or Negative Logic
Vin Negative
400 kHz
1500 VDC
1050 VDC
1050 VDC
0.02 ppm/°C
-40°C To +100°C
-40°C To +125°C
105°C To 115°C
5 g, 10 - 55 Hz
2.5 X 106 hrs
UL, cUL, TUV
1.7 oz
REV. JUN 04, 2004
Page 1 of 2
Notes
† MTBF predictions may vary slightly from model to model.
Specifications typically at 25°C, normal line, and full load, unless otherwise
stated.
Soldering Conditions: I/O pins, 260°C, ten seconds; fully compatible with
commercial wave-soldering equipment.
Safety: Agency approvals may vary from model to model. Please consult
factory for specific model information.
Units are water-washable and fully compatible with commercial spray or
immersion post wave-solder washing equipment.
QBS DC-DC Series Data Sheet
Model Selection
MODEL
INPUT VOLTAGE
(VOLTS)
INPUT VOLTAGE
RANGE (VOLTS)
MAXIMUM INPUT
CURRENT (AMPS)*
OUTPUT
VOLTAGE (VOLTS)
RATED OUTPUT
CURRENT (AMPS)
24
24
24
24
24
48
48
48
48
48
48
48
48
48
18 - 36
18 - 36
18 - 36
18 - 36
18 - 36
36 - 75
36 - 75
36 - 75
36 - 75
36 - 75
36 - 75
36 - 75
36 - 75
36 - 75
2.90
3.50
5.20
6.80
6.80
1.40
1.70
2.50
3.30
4.00
3.30
2.50
3.45
4.00
2.5
3.3
5
12
15
2.5
3.3
5
12
12
15
3.3
5
15
15.00
15.00
15.00
8.33
6.67
15.00
15.00
15.00
8.33
10.00
6.67
20.0
20.0
8.0
QBS038YD-A
QBS050YE-A
QBS075YG-A
QBS100YH-A
QBS100YJ-A
QBS038ZD-A
QBS050ZE-A
QBS075ZG-A
QBS100ZH-A
QBS120ZH-A
QBS100ZJ-A
QBS066ZE-A
QBS100ZG-A
QBS120ZJ-A
RIPPLE & NOISE
pk-pk (mV)
TYPICAL
EFFICIENCY**
100
100
100
150
150
100
100
100
150
150
150
100
100
150
76%
80%
84%
85%
85%
75%
78%
83%
86%
84%
86%
80%
82%
84%
NOTES:
* Maximum input current at minimum input voltage, maximum rated output power.
** At nominal Vin, rated output.
Model numbers highlighted in yellow or shaded are not recommended for new designs.
"
!
#!$
Thermal Impedance
Natural Convection
100 LFM
200 LFM
300 LFM
400 LFM
10.1 °C/W
8.0 °C/W
5.4 °C/W
4.4 °C/W
3.4 °C/W
Note:
Thermal impedance data is dependent on
many environmental factors. The exact
thermal performance should be validated
for specific application.
"
"
Pin
Mechanical Drawing
Tolerances
Function
1
-Vin
2
3
On/Off
+Vin
4
-Vout
5
6
7
8
-Sense
Trim
+Sense
+Vout
Inches:
.XX ± 0.020
.XXX ± .010
Pin:
± 0.002
(Millimeters)
.X ± 0.5
.XX ± 0.25
± 0.05
(Dimensions as listed unless otherwise specified.)
NUCLEAR AND MEDICAL APPLICATIONS - Power-One products are not authorized for use as critical components in life support systems,
equipment used in hazardous environments, or nuclear control systems without the express written consent of the respective divisional president
of Power-One, Inc.
TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending on the
date manufactured. Specifications are subject to change without notice.
REV. JUN 04, 2004
Page 2 of 2
很抱歉,暂时无法提供与“QBS038ZD-ANT”相匹配的价格&库存,您可以联系我们找货
免费人工找货