QHS DC/DC Series Data Sheet
Features
•
•
•
•
•
•
•
•
•
•
•
Applications
•
•
•
•
Distributed Power Architectures
Telecommunications Equipment
LAN/WAN Applications
Data Processing Applications
•
•
Low Profile – 12.7 mm Height
Input/output Isolation: 1500VDC, Basic
Insulation
High Efficiency - Up to 92% at Full Load
Start-up into High Capacitive Load
Low Conducted and Radiated EMI
Output Overcurrent Protection
Output Overvoltage Protection
Back Drive Protection
Overtemperature Protection
Remote Sense
Remote On/Off (Primary Referenced),
Positive or Negative Logic
Output Voltage Trim Adjust
UL 1950 Recognition, CSA 22.2 No. 950-95
certification, TUV IEC950
Description
The QHS is a series of high efficiency, high-density, single output DC/DC converters for onboard conversion of
standard telecom and datacom input voltages into isolated low voltage outputs in a through-hole mounting
package. The two-board construction provides a cool environment for control components and the integrated
metalic substrate PCB provides superior thermal management for power components resulting in enhanced
product reliability. A heatsink can be conveniently and effectively attached to the IMS base plate for operations in
elevated ambient conditions or where airflow is minimal.
Model Selection
Model
Input
Voltage
VDC
Input
Current, Max
ADC
QHS12ZH
QHS25ZG
QHS40ZE
QHS40ZD
QHS40ZB
QHS50ZA
QHS50ZY
36-75
36-75
36-75
36-75
36-75
36-75
36-75
4.5
4.3
4.5
3.3
2.5
2.7
2.3
Output
Voltage
Vout,
VDC
12.0
5.0
3.3
2.5
1.8
1.5
1.2
Output Rated
Current
I rated,
ADC
12
25
40
40
40
50
50
REV. JUL 17, 2003
Page 1 of 10
Output
Ripple/Noise,
mV p-p
Typical
Efficiency @
I rated, %
150
150
150
100
100
100
100
91
92
89
88
85
79
76
QHS DC/DC Series Data Sheet
Absolute Maximum Ratings
Stresses in excess of the absolute maximum ratings may cause performance degradation, adversely effect longterm reliability and cause permanent damage to the converter.
Table 1. Absolute Maximum Ratings
Parameter
Input voltage
Operating Temperature
Conditions/Description
Continuous
Transient
Base Plate Temperature
Min
Storage Temperature
ON/OFF Control Voltage
Units
VDC
VDC
-40
Max
75
80
100
-40
125
°C
20
VDC
Referenced to -Vin
°C
Environmental and Mechanical Specifications
All specifications apply over specified input voltage, output load, and temperature range, unless otherwise noted.
Table 2. Environmental and Mechanical Specifications
Parameter
Shock
Sinusoidal Vibration
Weight
Water Washing
MTBF
Conditions/Description
Halfsine wave, 3 axes
GR-63-Core, Section 5.4.2
Standard process
Per Bellcore TR-NWT-000332
REV. JUL 17, 2003
Page 2 of 10
Min
50
1
Nom
1.2/35
Yes
1,980
Max
Units
g
g
Oz/g
kHrs
QHS DC/DC Series Data Sheet
Isolation Specifications
All specifications apply over specified input voltage, output load, and temperature range, unless otherwise noted.
Table 3. Isolation Specifications
Parameter
Insulation Safety Rating
Isolation Voltage
Isolation Voltage
Isolation Resistance
Isolation Capacitance
Conditions/Description
Min
Input to output, input to base plate
Output to base plate
1500
500
10
Nom
Basic
Max
Units
VDC
VDC
MOhm
pF
1000
Input Specifications
All specifications apply over specified input voltage, output load, and temperature range, unless otherwise noted.
Table 4. Input Specifications
Parameter
Input Voltage
Turn-On Input Voltage
Turn-Off Input Voltage
Input over voltage protection
Turn-On Time
Input Reflected Ripple Current
Conditions/Description
Continuous
Ramping Up
Ramping Down
Ramping up
To Output Regulation Band
100% Resistive Load
Full Load, 12uH source inductance
Inrush Transient
Vin=Vin.max
REV. JUL 17, 2003
Page 3 of 10
Min
36
76
Nom
48
34
33
Max
75
84
5
Units
VDC
VDC
VDC
VDC
ms
60
mA p-p
0.1
As
2
QHS DC/DC Series Data Sheet
Output Specifications
All specifications apply over specified input voltage, output load and temperature range, unless otherwise noted.
Table 5. Output Specifications
Parameter
Output Voltage Setpoint Accuracy
1.8V
2.5V
3.3V
12V
Output Current*
Line Regulation
Load Regulation
Total output voltage regulation
Remote Sense Headroom***
Dynamic Regulation
Peak Deviation
Settling Time
Admissible Load Capacitance
Output Current Limit Threshold**
Switching Frequency
Overvoltage Protection,
Non Latching
Trim Range
Conditions/Description
Vin=Vin.nom, Full Load
See selection chart for Irated
Vin.min to Vin.max, Irated
Vin=Vin.nom, 10% to 100%Irated
Over all input voltage, load, and
temperature conditions
Min
Nom
-1.67
-2.00
-1.5
-2.0
0
-3
Max
Units
1.67
2.00
1.5
2.0
100
0.2
0.75
3
%Vout
%Vout
%Vout
%Vout
%Irated
%Vout
%Vout
%Vout
10%
%Vout
50-75% load step change
5
250
to 1% error band
%Vout
µs
Irated, Nom Vin
27,000
µF
12V
8,000
µF
150
Vout≤0.97Vout.nom
2.5V and 1.8V
3.3V
12V
Over all input voltage and load
conditions
Irated, Vin=Vnom
110
120
140
%Irated
kHz
kHz
kHz
%Vout
90
110
%Vout
300
450
400
* At Iout
很抱歉,暂时无法提供与“QHS40ZD-NT”相匹配的价格&库存,您可以联系我们找货