SFP650-12BG AC-DC Front-End Data Sheet 12V Output, 650 Watts
Features Ideal server form factor optimizes, space, efficiency, and load variations High efficiency maximized between 30-80% load conditions Unconditionally stable under any load condition Wide range DC-input model available (SFD550-12BG) Wide input voltage range (90-264 VAC) with PFC 1U or 2U height configurations Active current share with ORing FET I2C interface status monitoring Standby voltage of 3.3 VDC @ 3 A Overtemperature, overload, and overvoltage protection Status LEDs: AC OK, POWER GOOD, PS FAIL
Applications Datacom Distributed power systems
Description The SFP650-12BG is a 650-watt, power factor corrected (PFC) front-end which provides a 12 VDC output for datacom and other distributed power applications. Its compact size enables mounting in both 1U and 2U height racks. High efficiencies, advanced thermal management techniques, and an internal fan increase reliability over a broad range of operating conditions. Internal ORing diodes facilitate use in hot-swap (plug)1, redundant configurations. Status is provided with front panel LEDs, logic signals, and via the I2C management interface bus. The SFP650-12BG meets international safety requirements and is CE marked to the Low Voltage Directive (LVD).
Model Selection
Model Nominal Output Voltage (VDC) 12 3.3 (Standby) Adjustment Range (VDC) Maximum Output Current (Amps) 53.3 3 Regulation % ±3 ±3 Ripple & Noise @ 20 MHz BW (mV) 100 100
SFP650-12BG
N/A N/A
Proper hot-swap (plug) operation instruction: Power supply is not intended to be inserted into the system with AC cord already applied. Alternatively, if there is an application where power supply insertion with AC cord is required; PS_ON must be toggled or AC recycled after insertion into the system to reset the power supply.
1
BCD20033-G Rev.AB 31-Mar-09
Page 1 of 10
www.power-one.com
SFP650-12BG AC-DC Front-End Data Sheet 12V Output, 650 Watts
Input Specifications
Parameter AC Input Voltage Input Frequency Hold-up Time Input Current Inrush Surge Current Power Factor Conditions/Description Single-phase continuous input range. AC input. After last AC line peak at full power. At 115 VAC. At full-rated load. At 90 VAC. Min. 90 47 14 9 15 > 0.95 Nom. Max. 264 63 Units VAC Hz ms A rms A pk W/VA
Excluding Xcap. Vin = 264 VAC. 25 ºC Per EN61000-3-2
Output Specifications
Parameter Efficiency
NOTE: Internal fan is considered part of the load as it is driven from the 12V output; Vaux load is set to 0A for efficiency measurements.
Conditions/Description With Vin at 115VAC and 50% to 75% load on V1. With Vin at 115VAC and 75% to 100% load on V1. With Vin at 230VAC and 50% to 75% load on V1. With Vin at 230VAC and 75% to 100% load on V1.
Min. 86.0 86.0 87.0 89.0 0
Nom.
Max.
Units % % % % A
Minimum Load Output Power Overshoot Transient Response
Minimum loading required to maintain regulation.
650 Output voltage overshoot at turn-on. Maximum recovery time to within 1% of initial set point due to a 25% load change, 1A/µs. 12V output: Standby output: Maximum deviation: 12V output: Standby output:
很抱歉,暂时无法提供与“SFP650-12BG”相匹配的价格&库存,您可以联系我们找货