0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
YH09T40-0G

YH09T40-0G

  • 厂商:

    POWER-ONE

  • 封装:

    DIP15模块

  • 描述:

    非隔离 PoL 模块 直流转换器 1 输出 0.6 ~ 3.63V 40A 5V - 13.8V 输入

  • 数据手册
  • 价格&库存
YH09T40-0G 数据手册
YH09T40 40A DC-DC POL Converter 5V to 13.8V Input  0.6V to 3.63V Output Data Sheet Member of the Applications  Low voltage, high density systems with Intermediate Bus Architectures (IBA)  Point-of-load regulators for high performance DSP, FPGA, ASIC, and microprocessors  Desktops, servers, and portable computing  Broadband, networking, optical, and communications systems Benefits  One part that covers many applications  Reduces board space, system cost and complexity, and time to market Family Features  RoHS lead free and lead-solder-exempt products are available  High efficiency multiphase synchronous buck topology  Low noise fixed frequency operation  Wide input voltage range: 5V–13.8V  High continuous output current: 40A  Programmable output voltage range: 0.6V–3.63V  Overcurrent, output overvoltage, and overtemperature protections with automatic restart  Remote differential output voltage sense  Power Good signal  Enable input  Start up into prebiased load  No minimum load requirements  High MTBF of 40.5 Million hours  Industry standard size through-hole low profile package and pinout  1.45”x1.115” (36.83mm x 28.32mm)  Low height of 0.5” (12.7mm)  Wide operating temperature range: 0 to 70ºC  UL94 V-0 flammability rating  UL60950, CSA C22.2 No. 60950-00, and TUV EN60950-1:2001 Description Power-One’s point-of-load converters are recommended for use with regulated bus converters in an Intermediate Bus Architecture (IBA). The YH09T40-0 non-isolated DC-DC point of load (POL) converter delivers up to 40A of output current in an industry-standard horizontal through-hole package. The YH09T40-0 POL converter is an ideal choice for Intermediate Bus Architectures where point of load conversion is a requirement. Operating from a 5-13.8V input the POL converter provides an extremely tightly regulated programmable output voltage of 0.6 V to 3.63V. The POL converter offers exceptional thermal performance, even in high temperature environments with minimal airflow. This performance is accomplished through the use of advanced circuit solutions, packaging and processing techniques. The resulting design possesses ultra-high efficiency, excellent thermal management, and a slim body profile that minimizes impedance to system airflow, thus enhancing cooling for both upstream and downstream devices. The use of automation for assembly, coupled with advanced power electronics and thermal design, results in a product with extremely high reliability. ZD-02095 Rev. 1.1, 18-Jun-10 www.power-one.com Page 1 of 13 YH09T40 40A DC-DC POL Converter 5V to 13.8V Input  0.6V to 3.63V Output Data Sheet 1. Ordering Information Y H 09 T 40 – 0 z Product Family Profile Input Voltage PCB Mounting Output Current Dash ON/OFF Logic RoHS compliance 5V to 13.8V Throughhole Positive Logic No suffix - RoHS compliant 1 with Pb solder exemption G - RoHS compliant for all six substances POL Converter Horizontal 40A ______________________________________ 1 The solder exemption refers to all the restricted materials except lead in solder. These materials are Cadmium (Cd), Hexavalent chromium (Cr6+), Mercury (Hg), Polybrominated biphenyls (PBB), Polybrominated diphenylethers (PBDE), and Lead (Pb) used anywhere except in solder. Example: YH09T40-0G: YH09T40-0 POL converter with lead-free solder. Model numbers highlighted in yellow or shaded are not recommended for new designs. 2. Absolute Maximum Ratings Stresses in excess of the absolute maximum ratings may cause performance degradation, adversely affect longterm reliability, and cause permanent damage to the converter. Parameter Conditions/Description Min Max Units Input Voltage Continuous -0.3 15 VDC Ambient Temperature Range Operating 0 70 C -55 125 C 120 C Storage Temperature (Ts) Case Temperature (Tc) 3. Measured on MOSFET Q120 Environmental and Mechanical Specifications Parameter Conditions/Description Weight MTBF Calculated Per Telcordia Technologies SR-332, Method I Case 1 50% electrical stress, 40°C ambient Lead Plating YH09T40-0 and YH09T40-0G ZD-02095 Rev. 1.1, 18-Jun-10 www.power-one.com Min Nom Max Units 16.4 grams 40.5 MHrs 100% Matte Tin Page 2 of 13 YH09T40 40A DC-DC POL Converter 5V to 13.8V Input  0.6V to 3.63V Output Data Sheet 4. Electrical Specifications Specifications apply at the input voltage from 5V to 13.8V, output load from 0 to 40A, output voltage from 0.6V to 3.63V, 470µF external output capacitor, and ambient temperature from 0°C to 70°C unless otherwise noted. 4.1 Input Specifications Parameter Conditions/Description Min Nom Max Units Input voltage (VIN) VOUT≤0.55*VIN 5 12 13.8 VDC Input Voltage Ramping Up 4.25 4.5 4.75 VDC Input Voltage Ramping Down 3.75 4.0 4.25 VDC Undervoltage Lockout Turn On Threshold Undervoltage Lockout Turn Off Threshold Standby Input Current VIN=12V, POL is disabled via ON/OFF Maximum Input Current VIN=6V, VOUT=3.3V Input Reflected Ripple Current Peak-to-Peak BW=5MHz to 20MHz, LSOURCE=1µH, See Figure 20 for setup 4.2 16 mADC 25 130 ADC mA Output Specifications Parameter Conditions/Description Min Output Voltage Range (VOUT) Programmable with a resistor between TRIM+ and TRIM- pins Output Voltage Setpoint Accuracy, VOUT≥1V Output Voltage Setpoint Accuracy, VOUT
YH09T40-0G 价格&库存

很抱歉,暂时无法提供与“YH09T40-0G”相匹配的价格&库存,您可以联系我们找货

免费人工找货