CXA-0231

CXA-0231

  • 厂商:

    POWER-SYSTEMS

  • 封装:

  • 描述:

    CXA-0231 - DC-AC INVERTER UNIT 8W DUAL OUTPUTS WITH WIDE DIMMING FUNCTION - Power Systems GmbH+Co.KG

  • 数据手册
  • 价格&库存
CXA-0231 数据手册
DC-AC INVERTER UNIT CXA-0231 (8W DUAL OUTPUTS WITH WIDE DIMMING FUNCTION) DESCRIPTION : This DC to AC Inverter was developed for large size LCD panel as Multiple Media , Replacement of CRT Monitor and other general Purpose. APPLICABLE LCD: 10.4 to 15 inches Double lamps type Lamp Voltage 500~700V Lamp Current 6mA typ. FEATURES : Wide Input Voltage Wide Dimmng Range (By Internal PWM Control Circuit) Individual Lamp Current Feedback Same Mounting Hole Position (CXA-0217, CXA-P1212-VJL etc...) Low noise with voltage resonant circuit No High Voltage Pattern on Bottom Side High Efficiency 8mm Low Profile. Fuse Protection TEMPERATURE & HUMDITY : Operating Temperature Range Storage Temperature Range Humidity DIMENSIONS : 0 °C ~ +70°C -30 °C ~ +85°C 95 %RH max 180.0 ± 0.5 max 146.5±0.2 80±0.2 CXA-0231 Lot 7X Made in Japan (PRELIMINARY INFORMATION) 3.5±0.5 Unit : mm Weight : 30 (g) typ. 25.3 max 18±0.2 CN3 1 1 CN1 4 3-φ3±0.2 2 1 3 CN2 1 8 max 3.5±0.5 No. 1 2 3 4 Part Discription PW B Connector CN1 Connector CN2 Connector CN3 Qty. 1 1 1 1 Material UL94V-0 (FR-4 or CEM-3) S5B-PH-SM3 SM02(8.0)B-BHS-1 SM02(8.0)B-BHS-1 Note t=1mm JST JST JST Power Systems – The Power Solution Web: Email: www.Power-Systems.de Info@Power-Systems.de Page ( 1 / 4 ) Address: Dörnet 8 ; 74360 Ilsfeld-Auenstein / Germany Tel. : + 49 / 70 62 / 67 59 - 6 Fax: + 49 / 70 62 / 67 59 - 80 VER, 04 October 2002 All specification are subject to change without notice. (5.5) DC-AC INVERTER UNIT CXA-0231 (8W DUAL OUTPUTS WITH WIDE DIMMING FUNCTION) Input Side CN1: Output Side CN2: (PRELIMINARY INFORMATION) Output Side CN3: Rating s 670 Vrms (2V) Pin CN CN CN CN No. Symbols Vin 1-1 GND 1-2 Vbr 1-3 1-4 Vrmt CN 1-5 Ratings 9.6-14.4V 0V 0-1.5V N.C. 0-0.4V OFF / 2-14.4V ON Pin CN CN CN No. Symbols 2-1 V HIGH1 N.C. 2-2 2-3 V LOW1 Pin CN CN CN No. Symbols 3-1 V HIGH2 N.C. 3-2 3-3 V LOW2 Ratings 670 Vrms (2V) ELECTRICAL CHARACTERISTICS : Condition Ite m s Output Curre nt Input Curre nt 1 Input Curre nt 2 Fre que ncy 1 Fre que ncy 2 Fre que ncy (Duty) Ope n Circuit V oltage Dim m ing Function Dim m ing Function (Note 8) Sym bols Iout1/2 Iin1 Iin2 F1 F2 F3 V ope n Iout1/2 Iout1/2 V in (V ) 12±2.4 12±0.6 12±2.4 12±0.6 12±2.4 12±0.6 12±2.4 12±0.6 12±2.4 12±0.6 12±2.4 12±0.6 12±2.4 12±0.6 12±2.4 12±0.6 12±2.4 12±0.6 V rm t (V ) 5±0.25 5±0.25 5±0.25 5±0.25 0~0.4 0~0.4 5±0.25 5±0.25 5±0.25 5±0.25 5±0.25 5±0.25 5±0.25 5±0.25 5±0.25 5±0.25 5±0.25 5±0.25 V br (V ) 0 0 0~1.5 0~1.5 0~1.5 0~1.5 0 0 0 0 1.0±0.05 1.0±0.05 0 0 1.3±0.05 1.3±0.05 1.7±0.05 1.5±0.05 Ta (°C) 0~70 25±1.0 0~70 25±1.0 0~70 25±1.0 0~70 25±1.0 0~70 25±1.0 0~70 25±1.0 0~70 25±1.0 0~70 25±1.0 0~70 25±1.0 RL1 (KΩ ) / RL2 (KΩ ) 75~112 95±0.5 75~112 95±0.5 75~112 95±0.5 75~112 95±0.5 75~112 95±0.5 75~112 95±0.5 ∞ ∞ 75~112 95±0.5 75~112 95±0.5 Spe cifications M in. 5.3 5.5 53 54 55 56 225 225 1500 1500 0.4 0.6 Typ. 6.0 6.0 0.78 60 60 62 62 270 270 1700 1700 1.5 1.5 M ax. 6.7 6.5 1.6 1.4 1 1 67 66 69 68 335 315 2.6 2.4 0 0 Unit m Arm s A DC m A DC k Hz Hz V rm s m Arm s DIMMING CHARACTERISTICS (Reference) 7 6 Iout (mArms) 5 4 3 2 1 0 0 0,1 0,2 0,3 0,4 0,5 0,6 0,7 0,8 0,9 1 1,1 1,2 1,3 Vbr (VDC) Power Systems – The Power Solution Web: Email: www.Power-Systems.de Info@Power-Systems.de Page ( 2 / 4 ) Address: Dörnet 8 ; 74360 Ilsfeld-Auenstein / Germany Tel. : + 49 / 70 62 / 67 59 - 6 Fax: + 49 / 70 62 / 67 59 - 80 VER, 04 October 2002 All specification are subject to change without notice. DC-AC INVERTER UNIT CXA-0231 (8W DUAL OUTPUTS WITH WIDE DIMMING FUNCTION) (PRELIMINARY INFORMATION) APPLICATION (for example) Voltage Dimming Type CN1-1(Vin) Vin 9.6~14.4V SW On Vrmt 5~14.4V Off CN1-3(Vbr) Vbr 0..1,3VDC Iout2 CN1-4(NC) CN3-3(VLOW2) CN1-2(GND) CN1-5(Vrmt) CN2-3(VLOW1) CN3-1(VHIGH2) CCFL2 RL2 CN2-1(VHIGH1) CCFL1 RL1 CN1-1 Vin 10kΩ NPN 10kΩ 10kΩ IC1 10kΩ PNP REMOTE TERMINAL CIRCUIT (Reference) Iout1 CN1-5 Vrmt None Dimming Type CN1-1(Vin) Vin 9.6~14.4V CN1-2(GND) CN1-5(Vrmt) CN1-3(Vbr) Iout2 CN1-4(NC) CN3-3(VLOW2) CN2-3(VLOW1) CN3-1(VHIGH2) CCFL2 RL2 CN2-1(VHIGH1) CCFL1 RL1 Iout1 TEST CIRCUIT Iin A V CN1-1 Vin CN1-2 GND CN1-3 Vbr Vbr 0~1.3V CN1-4 NC CN1-5 Vrmt Q6 T1 C10 CN2-1 Vhigh1 RL Vin 9.6 ~14.4V Vopen F1 CN2-3 Vlow1 Q13 T2 C25 CN3-1 Vhigh2 Iout1 A RL b Vrmt 5V a SW F2 CN3-3 Vlow2 Iout2 A F 1000:1 V Power Systems – The Power Solution Web: Email: www.Power-Systems.de Info@Power-Systems.de Page ( 3 / 4 ) Address: Dörnet 8 ; 74360 Ilsfeld-Auenstein / Germany Tel. : + 49 / 70 62 / 67 59 - 6 Fax: + 49 / 70 62 / 67 59 - 80 VER, 04 October 2002 All specification are subject to change without notice. DC-AC INVERTER UNIT CXA-0231 (8W DUAL OUTPUTS WITH WIDE DIMMING FUNCTION) Note 1. Note 2. Note 3. Note 4. For circuit connection, please prefer to test circuit diagram Please use minimum of 2mm clearance (all directions) between inverter high voltage area and any conductors. Please refer to mechanical drawing for marking of high voltage area. Open voltage (strike voltage) is measured across the transformer secondary winding at no load as the reading at the output connector would be less than the actual value If the start voltage falls below Cold Cathode Tube strike voltage, the CCFL will not light up easily specially at lower ambient temperature. Please review mounting instruction to avoid any abnormal operation due to coupling/leakage capacitance of inverter high voltage area to any surrounding conductor. Please check your lamp characteristic for minimum operational current and set the limit point in your design to avoid flickering and/or abnormal operation. For proper operation of circuit protection (FUSE or IC PROTECTOR), please use minimum of 2A capacity for input power supply. The recommendation range of Vbr is 0 to 1.3V and normal dimming range is 1.3 to 1.5V. However each lamp has deferent characteristics, therefore care must be taken to check brightness with using lamp and DC to AC Inverter units combination to avoid flickering or other problems. (PRELIMINARY INFORMATION) Note 5. Note 6. Note 7. Power Systems – The Power Solution Web: Email: www.Power-Systems.de Info@Power-Systems.de Page ( 4 / 4 ) Address: Dörnet 8 ; 74360 Ilsfeld-Auenstein / Germany Tel. : + 49 / 70 62 / 67 59 - 6 Fax: + 49 / 70 62 / 67 59 - 80 VER, 04 October 2002 All specification are subject to change without notice.
CXA-0231 价格&库存

很抱歉,暂时无法提供与“CXA-0231”相匹配的价格&库存,您可以联系我们找货

免费人工找货