0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
CXA-P1012-NJL

CXA-P1012-NJL

  • 厂商:

    POWER-SYSTEMS

  • 封装:

  • 描述:

    CXA-P1012-NJL - DC-AC INVERTER UNIT 9.0W DUAL OUTPUTS - Power Systems GmbH+Co.KG

  • 数据手册
  • 价格&库存
CXA-P1012-NJL 数据手册
DC-AC INVERTER UNIT CXA-P1012-NJL (9.0W DUAL OUTPUTS) DESCRIPTION: This DC to AC Inverter was developed for large size LCD panel as Multiple Media, Replacement of CRT Monitor and other general Purpose. APPLICABLE LCD: 9 to 15 inches Double lamp type Lamp Voltage 600V Lamp Current 5mA FEATURES : High Efficiency (85%) Fuse protection Low noise with voltage resonant circuit 8mm Low Profile TEMPERATURE & HUMDITY : Operating Temperature Range Storage Temperature Range Humidity DIMENSIONS : -10 °C ~ +60°C -30 °C ~ +85°C 95 %RH max (PRELIMINARY INFORMATION) CXA-P1012-NJL LOT. 7X MADE IN JAPAN 130.5 max 124±0.2 3±0.3 14±0.2 (3) 48±0.2 3-φ2.2±0.1 20.5 max CN2 1 1 CN1 b 8 max CN3 1 Unit: mm Weight: 21.0g typ. 3±0.3 4 b 2 1 3 No. 1 2 3 4 P art Dis c ription P CB Connec tor CN1 Connec tor CN2 Connec tor CN3 Qty . 1 1 1 1 M aterial UL94V -0 (FR-4 or CE M -3) S 5B -P H-S M 3 S M 02(8.0)B -B HS -1 S M 02(8.0)B -B HS -1 Note t= 1.0m m JS T JS T JS T Power Systems – The Power Solution Web: Email: www.Power-Systems.de Info@Power-Systems.de Page ( 1 / 4 ) Address: Dörnet 8 ; 74360 Ilsfeld-Auenstein / Germany Tel. : + 49 / 70 62 / 67 59 - 6 Fax: + 49 / 70 62 / 67 59 - 80 VER, 04 October 2002 All specification are subject to change without notice. DC-AC INVERTER UNIT CXA-P1012-NJL (9.0W DUAL OUTPUTS) (PRELIMINARY INFORMATION) Input Side CN1: Output Side CN2, CN3: P in CN CN CN CN CN No. S ym bols 1-1 V in 1-2 GND 1-3 N.C. 1-4 1-5 Ra tings 12V 0V - P in No. CN 2-1 CN 2-2 CN 2-3 CN 3-1 CN 3-2 CN 3-3 S ym bols V HIGH 1, 2 N.C. V LOW 1, 2 Ra tings 600 V rm s (2V ) ELECTRICAL CHARACTERISTICS: Ite m s S ym bols Iout1 Conditions S pe cifica tion Typ. M a x . 5.0 5.0 620 37 5.5 V in (V ) Ta (°C) RL 1, 2 (K Ω ) M in. 12±0.12 18~ 28 120 4.5 4.0 12±0.6 -10~ 60 110~ 130 30 ∞ Unit Output Curre nt Iout2 Iout1 Iout2 Iin F V ope n 1, 2 m Arm s 6.0 900 44 m A DC kHz V rm s Input Curre nt Fre que ncy Ope n Circuit V olta ge 1400 1500 Power Systems – The Power Solution Web: Email: www.Power-Systems.de Info@Power-Systems.de Page ( 2 / 4 ) Address: Dörnet 8 ; 74360 Ilsfeld-Auenstein / Germany Tel. : + 49 / 70 62 / 67 59 - 6 Fax: + 49 / 70 62 / 67 59 - 80 VER, 04 October 2002 All specification are subject to change without notice. DC-AC INVERTER UNIT CXA-P1012-NJL (9.0W DUAL OUTPUTS) APPLICATION (For Example): Non Dimming Type CN1-1(Vin) Vin 12V CN1-2(GND) CN1-5(NC) CN1-3(NC) CN1-4(NC) CN3-3(Vlow2) CN2-3(Vlow1) CN3-1(Vhigh2) Iout2 CCFL2 RL2 CN2-1(Vhigh1) Iout1 CCFL1 RL1 (PRELIMINARY INFORMATION) Dimming by DC/DC Converter CN1-1(Vin) CN1-2(GND) CN2-1(Vhigh1) Iout1 CCFL1 RL1 DC/DC Converter (Mother Board) CN1-5(NC) CN1-3(NC) CN1-4(NC) CN2-3(Vlow1) CN3-1(Vhigh2) Iout2 CCFL2 RL2 CN3-3(Vlow2) Dimming by PWM CN1-1(Vin) CN1-2(GND) CN2-1(Vhigh1) Iout1 CCFL1 RL1 Duty Dimmig (Mother Board) CN1-5(NC) CN1-3(NC) CN1-4(NC) CN2-3(Vlow1) CN3-1(Vhigh2) Iout2 CCFL2 RL2 CN3-3(Vlow2) TEST CIRCUIT: F O s c illo s c o p e V ~ C N 1-1 V C N 2-1 C N 2-3 A ~ R L1 Io u t1 V ~ C N 3-1 C N 3-3 A ~ R L2 Io u t2 1 0 0 0 :1 V open2 1 0 0 0 :1 V open1 V in 12V A - Ii n - C N 1-2 NC NC NC C N 1-3 C N 1-4 C N 1-5 Power Systems – The Power Solution Web: Email: www.Power-Systems.de Info@Power-Systems.de Page ( 3 / 4 ) Address: Dörnet 8 ; 74360 Ilsfeld-Auenstein / Germany Tel. : + 49 / 70 62 / 67 59 - 6 Fax: + 49 / 70 62 / 67 59 - 80 VER, 04 October 2002 All specification are subject to change without notice. DC-AC INVERTER UNIT CXA-P1012-NJL (9.0W DUAL OUTPUTS) Note 1. Note 2. Note 3. Note 4. Note 5. For circuit connection, please prefer to test circuit diagram. Please use minimum of 2mm clearance (all directions) between inverter high voltage area and any conductors. Please refer to mechanical drawing for marking of high voltage area. Open voltage (strike voltage) is measured across the transformer secondary winding at no load as the reading at the output connector would be less than the actual value. The output of this dc-ac inverter is insulated in electricity with the input part. Please use CN2-3 and CN3-3 side when you connect the Vlow side of the output with the ground. Please use the screw of the insulator to prevent the electrical discharge or make the installation. Screw the first side and an insulated structure in electricity because the output pattern of a high voltage is laid out to be near when you use the installation hold of part b in the externals dimensional drawing. If the start up voltage falls below Cold Cathode Tube strike voltage, the CCFL will not light up easily specially at lower ambient temperature. Please review mounting instruction to avoid any abnormal operation due to coupling/leakage capacitance of inverter high voltage area to any surrounding conductor. (PRELIMINARY INFORMATION) Note 6. Power Systems – The Power Solution Web: Email: www.Power-Systems.de Info@Power-Systems.de Page ( 4 / 4 ) Address: Dörnet 8 ; 74360 Ilsfeld-Auenstein / Germany Tel. : + 49 / 70 62 / 67 59 - 6 Fax: + 49 / 70 62 / 67 59 - 80 VER, 04 October 2002 All specification are subject to change without notice.
CXA-P1012-NJL 价格&库存

很抱歉,暂时无法提供与“CXA-P1012-NJL”相匹配的价格&库存,您可以联系我们找货

免费人工找货