DC-AC INVERTER UNIT PS-DA0105-01(S) (4 W SINGLE OUTPUTS) DESCRIPTION : This low profile DC to AC Inverter is developed for single lamps. (PRELIMINARY INFORMATION) APPLICABLE LCD: 6.4 to 15 inches single lamp type Lamp Voltage 727 Vrms Lamp Current 5.5 mArms Lamp Start Up Voltage 1.300 Vrms (Vin : 10.3 Vdc) FEATURES : Remote ON/OFF Open Lamp Detection Optional Extra wide Dimming range Optional different Dimming Voltage RoHS compliant (S) TEMPERATURE & HUMIDITY : Operating Temperature Range Storage Temperature Range Humidity DIMENSIONS : LxWxH 0°C ~ +50°C -20°C ~ +85°C 95 %RH max 93 x 16 x 6,5mm Unit : mm Weight :7,6 (g) typ. Note: Please use plastic screw in case of a non-insulating mounting base! Components No. 1 2 3 Part Description PCB Connector CN1 Connector CN2 Qty. 1 1 1 Material UL94V-0 (FR-4 or CEM-3) 53261-0590 SM02B-BHSS-1-TB Output side CN2 Note t=1m m Molex or equal JST or equal Input side CN1: Pin No. Symbols Vin CN 1-1 GND CN 1-2 Vbr CN 1-3 GND CN 1-4 CN 1-5 Vrm t Ratings 9.0 ~ 15.0 Vdc 0 ~ 3 Vdc (optional 0 ~ 5 Vdc) 0 ~ 0.4 = OFF / 2.5 ~ Vin = ON Pin No. CN 2-1 CN 2-2 Symbols Vhigh Vlow Ratings 727 Vrm s (5,5 m Arm s ) (GND) Power Systems – The Power Solution Web: Email: www.Power-Systems.de Info@Power-Systems.de Page (1) Address: Hauptstr. 48 ; 74360 Ilsfeld-Auenstein / Germany Tel. : + 49 / 70 62 / 67 59 - 6 Fax: + 49 / 70 62 / 67 59 - 800 Version 1.5.1, 22th March 2007 All specifications are subject to change without notice. SM02(8.0)B - BHS (JST) 1 DC-AC INVERTER UNIT PS-DA0105-01(S) (4 W SINGLE OUTPUTS) ELECTRICAL CHARACTERISTICS : Conditions Parameters Output Current Output Current Input Current Frequency Open Circuit Voltage No load Shutdown Symbols Iout Iout Iin F Vopen Ts d Vin (V) 10.3±1.2 10.3±0.6 10.3±1.2 10.3±1.2 10.3 10.3±1.2 Vbr (V) Tu (°C) 3.0 0.0 3.0 3.0 3.0 3.0 0 ~ +50 0 ~ +50 0 0 0 0 ~ +50 ~ +50 ~ +50 ~ +50 Min. 5.0 50 1.100 Specification Typ. 5.5 22 0.4 60 1.300 1.0 Max. 6.0 70 1.500 Unit m Arm s % Adc kHz Vrm s s ec Note Dut y 100 % Duty M in (opt io nal 10 % ) (PRELIMINARY INFORMATION) witho ut lo ad Note 1 : Note 2 : Note 3 : Please keep minimum of 2mm clearance (all directions) between inverter high voltage area as marked on mechanical drawing and any conductors. Vbr Standard 0 ~ 3 Vdc and optional 0 ~ 5 Vdc (Suffix –A, example PS-DA0105-01-A) Dimming range standard 100 ~ 22 % and optional 100 ~ 10 % (Suffix –W, example PS-DA0105-01-W) TEST CIRCUIT : Vin 10.3 V A Iin V F F 1000:1 PROBE Vopen CN1-1 SW3 CN2-1 V ~ SW 1 a Operation of unit Operation Non operation CN1-2 T1 CN2-2 SW4 RL1 CL1 b CN1-3 Vbr 0 ~ 3 Vdc CN1-4 A ~ Iout1 Vrmt 0.4 / 5 Vdc a V b SW1 CN1-5 Power Systems – The Power Solution Web: Email: www.Power-Systems.de Info@Power-Systems.de Page (2) Address: Hauptstr. 48 ; 74360 Ilsfeld-Auenstein / Germany Tel. : + 49 / 70 62 / 67 59 - 6 Fax: + 49 / 70 62 / 67 59 - 800 Version 1.5.1, 22th March 2007 All specifications are subject to change without notice. DC-AC INVERTER UNIT BACKLIGHT INVERTER INSTALLATION INSTRUCTION Precautionary Notes Regarding the Use of This Inverter When using this product, give due consideration to the precautionary notes described below and ensure a safe design. Inappropriate use may result in electric shock, injury or fire. WARNING • This product is subject to high voltage. Do not touch it while the power is on. Failing to do so may result in electric shock. CAUTION • This product is designed for the lighting of a Cold Cathode Fluorescent Lamp. Do not use it with any other load. • Store this product under the conditions defined in the specification document. • Do not store this product in an environment where dust, dirt or corrosive gas (salt, acid, base, etc.) is present. • This product is subject to high voltage. If there is a possibility that the user may touch the product, provide a proper indication in order to draw the user’s attention. • This product is designed for use with general electronic equipment. If it is to be used with medical equipment that directly affects human life or for the control of transportation equipment to which passengers entrust their lives, provide thorough failsafe measures. • Avoid using this product under high temperatures or high humidity or in an environment in which dust, dirt or any corrosive gas (salt, acid, base, etc.) is present. Also, be careful not to allow the formation of dew condensation. It may result in damage or electric shock. • If the product does not have a built-in protective circuit (circuit breaker, fuse, etc.), it is recommended that a fuse be used at the input stage to prevent the generation of smoke or fire in the event of a malfunction. Even when the product has a built-in protective circuit (circuit breaker, fuse, etc.), the circuit may not function properly due to inappropriate operating conditions or power-supply capacity. It is recommended that an appropriate protective circuit (circuit breaker, fuse, etc.) be provided separately from the built-in circuit. • Use the product only within the specified input voltage, output power, output voltage and operating temperature ranges. Exceeding these values may result in damage, etc. Abnormal voltage may result in damage, etc. • Provide a measure for the preventation of surge voltage due to lighting, etc. Abnormal voltage may result in damage, etc. • To prevent problems arising form short-circuiting of the high-voltage section, provide appropriate measures to prevent the entry of foreign substances following installation. • This product is not designed to provide resistance to radiation. HANDLING PRECAUTIONS • This product uses thin wires. Observe the following precautions and handle it with care so as not to cause wire breakage. Broken wire may result in damage, etc. Do not stack multiple products on top of one another, Do not allow the product to come in contact with tools, etc. • Do not apply excessive stress during installation. It may cause chipping and cracking, resulting in damage, etc • Provide a clearance of 2 mm or more between the high-voltage section of this product and the frame body on which the product is installed and also the conductor section (pattern, pad, etc.) Power Systems – The Power Solution Web: Email: www.Power-Systems.de Info@Power-Systems.de Page (1) Address: Hauptstr. 48 ; 74360 Ilsfeld-Auenstein / Germany Tel. : + 49 / 70 62 / 67 59 - 6 Fax: + 49 / 70 62 / 67 59 - 800 Version 2.0, 15th August 2007 All specifications are subject to change without notice. DC-AC INVERTER UNIT Thank you very much for usually patronizing Power Systems and TDK’s DC/AC inverter. Following the expansion of it’s use, there are unexpected troubles that are caused by mis-use or mis-handling because the DC/AC inverter generates a high voltage of 900Vrms or more. Hereafter, the cases of the major troubles are described. Please also refer to “Notes of used” of the attached paper. Ex.1 Multilayered PWB Inverter was mounted the nearest to the main board because there is no surface pattern. However, dielectric breakdown happened because there was a low-voltage pattern in internal layer, and they were damaged by arc fire. Ex.2 Foreign body Short of high voltage area by insect (cockroach etc.) having invaded installed set in food processing plant and counter, etc. Short by adhesion of metal powder when using it by set such as NC machine tool. Ex.3 Mechanical stress Parts will be cracked or the wire of transformer will be broke, etc. When the mechanical stress was given at the installation on the set. Ex.4 Storage, handling When you store it, if the product is piled up or grabed with other inverters together at once, etc. these will be the cause of the break of transformer’s wire and etc. CABLES CONNECTION 1.) Don‘t extand cables. 1.1.) Don‘t cut through nor solder them, unless you have consulted the manufacture. 2.) Don‘t exchange cables. 2.1.) Polarity is very important otherwise -will be able to a short circuit. -there might be a short circuit.(Please refer to fig.1) Fig. 1 OK NG Power Systems – The Power Solution Web: Email: www.Power-Systems.de Info@Power-Systems.de Page (2) Address: Hauptstr. 48 ; 74360 Ilsfeld-Auenstein / Germany Tel. : + 49 / 70 62 / 67 59 - 6 Fax: + 49 / 70 62 / 67 59 - 800 Version 2.0, 15th August 2007 All specifications are subject to change without notice.
PS-DA0105-01
1. 物料型号: - 型号为PS-DA0105-01(S),这是一个4瓦单输出的DC-AC逆变器单元。

2. 器件简介: - 该DC-AC逆变器设计用于单个灯管,具有低轮廓,适用于6.4至15英寸单灯型LCD,灯管电压为727Vrms,灯管电流为5.5mArms,灯管启动电压为1.300Vrms(输入电压为10.3Vdc)。

3. 引脚分配: - 输入侧CN1: - CN1-1:Vin,电压等级为9.0~15.0 Vdc。 - CN1-2:GND。 - CN1-3:Vbr,电压等级为0~3Vdc(可选0~5Vdc)。 - CN1-4:GND。 - CN1-5:Vrmt,电压等级为0~0.4=OFF/2.5~Vin=ON。 - 输出侧CN2: - CN2-1:Vhigh,电压等级为727Vrms(5.5mArms)。 - CN2-2:Vlow(GND)。

4. 参数特性: - 输入电压范围:9.0~15.0 Vdc。 - 输出电流:在10.3±1.2Vdc下,最小3.0mArms,典型5.5mArms,最大6.0mArms。 - 频率:在10.3±1.2Vdc下,最小50kHz,典型60kHz,最大70kHz。 - 开路电压:在10.3V下,最小1.100Vrms,典型1.300Vrms,最大1.500Vrms。 - 无负载关闭时间:在10.3±1.2Vdc下,1.0秒。

5. 功能详解: - 该逆变器具有远程开关功能、开灯检测、可选的额外宽调光范围、可选的不同调光电压,并且符合RoHS标准。

6. 应用信息: - 适用于6.4至15英寸单灯型LCD。

7. 封装信息: - 尺寸为长93mm、宽16mm、高6.5mm。
PS-DA0105-01 价格&库存

很抱歉,暂时无法提供与“PS-DA0105-01”相匹配的价格&库存,您可以联系我们找货