DC-AC INVERTER UNIT
PS-DA0129-184 (S) (5 W SINGLE OUTPUT)
DESCRIPTION : This DC to AC Inverter was developed for notebook computer and many other low LCD Backlight power supply as low profile applications, either for Note Book PC or Industrial. Optimized for Kyocera: TCG057QV1AA-G00 APPLICABLE LCD: 10 to 12 inches single lamp type Lamp Voltage 685 Vrms Lamp Current 4.0 mArms Lamp Start Up Voltage 1.600 Vrms (Vin : 5 Vdc) FEATURES : Current Feedback Circuit High Efficiency Low noise with voltage resonant circuit Regulated output current RoHS compliant (S) TEMPERATURE & HUMIDITY : Operating Temperature Range Storage Temperature Range Humidity DIMENSIONS : LxBxH -10°C ~ +60°C -20°C ~ +85°C 95 %RH max (PRELIMINARY INFORMATION)
95.5 x 20.0 x 9.5
Pin 1
Pin 1
Unit : mm Weight :20(g) typ.
Note: Please use plastic screw in case of a non-insulating mounting base!
Components No. 1 2 3 Part Description PCB Connector CN1 Connector CN2 Qty. 1 1 1 Material UL94V-0 (FR-4 or CEM-3) 53261-0590 SM02(8.0)B-BHSS-1-TB Output side CN2 Pin No. CN 2-1 CN 2-2 CN 2-3 Symbols Vhigh N.C. Vlow Ratings 685Vrm s (4.0 m Arm s ) (GND) Note t=1m m Molex or equal JST or equal
Input side CN1: Pin No. CN 1-1 CN 1-2 CN 1-3 CN 1-4 CN 1-5 Symbols Ratings Vin 4.5 ~ 5.5 Vdc GND Vrm t 0 ~ 0.5 = OFF / 2.5 ~ Vin = ON Vbr 0 ~ 3 Vdc N.C. -
Power Systems – The Power Solution
Web: Email: www.Power-Systems.de Info@Power-Systems.de
Page (1)
Address: Hauptstr. 48 ; 74360 Ilsfeld-Auenstein / Germany Tel. : + 49 / 70 62 / 67 59 - 6 Fax: + 49 / 70 62 / 67 59 - 800
Version 1.0, 29th August 2007
All specifications are subject to change without notice.
DC-AC INVERTER UNIT
PS-DA0129-184 (S) (5 W SINGLE OUTPUT)
ELECTRICAL CHARACTERISTICS : (PRELIMINARY INFORMATION)
Conditions Symbols Iout Iout Iin F Vopen Ts d Vin (V) 5±0.25 5±0.25 5±0.25 5±0.25 5±0.25 5±0.25 Vbr (V) 0.0 3.0 0.0 0.0 0.0 0.0 Tu (°C) -10 -10 -10 -10 -10 ~ ~ ~ ~ ~ +60 +60 +60 +60 +60 Min. 3.5 2.0 35 1.500 -
Specification Typ. 4.0 2.5 0.8 45 1.600 1.0 Max. 4.5 3.0 1.0 55 1.800 Unit m Arm s m Arm s Adc kHz Vrm s s ec Note
Dut y = 10 0 % Dut y = 50 % min.
-10 ~ +60
wit ho ut lo ad
Note 1 :
Please keep minimum of 2mm clearance (all directions) between inverter high voltage area as marked on mechanical drawing and any conductors.
TEST CIRCUIT :
SW 1 a b Operation of unit Operation Non operation
Power Systems – The Power Solution
Web: Email: www.Power-Systems.de Info@Power-Systems.de
Page (2)
Address: Hauptstr. 48 ; 74360 Ilsfeld-Auenstein / Germany Tel. : + 49 / 70 62 / 67 59 - 6 Fax: + 49 / 70 62 / 67 59 - 800
Version 1.0, 29th August 2007
All specifications are subject to change without notice.
很抱歉,暂时无法提供与“PS-DA0129-184”相匹配的价格&库存,您可以联系我们找货