0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
PS-DA0201-01S

PS-DA0201-01S

  • 厂商:

    POWER-SYSTEMS

  • 封装:

  • 描述:

    PS-DA0201-01S - DC-AC INVERTER UNIT 10 W DUAL OUTPUTS - Power Systems GmbH+Co.KG

  • 详情介绍
  • 数据手册
  • 价格&库存
PS-DA0201-01S 数据手册
DC-AC INVERTER UNIT PS-DA0201-01(S) (10 W DUAL OUTPUTS) DESCRIPTION : This low profile DC to AC Inverter is developed for dual lamps. (PRELIMINARY INFORMATION) APPLICABLE LCD: 6.4 to 15 inches double lamp type Lamp Voltage 714 Vrms Lamp Current 2 x 7 mArms Lamp Start Up Voltage 1.500 Vrms (Vin : 12 Vdc) FEATURES : Remote ON/OFF Open Lamp Detection RoHS compliant (S) TEMPERATURE & HUMIDITY : Operating Temperature Range Storage Temperature Range Humidity DIMENSIONS : LxWxH 0°C ~ +60°C -40°C ~ +85°C 95 %RH max Unit : mm Weight :24,2 (g) typ. 160 x 25 x 10 mm Components No. 1 2 3 Note: Please use plastic screw in case of a non-insulating mounting base! Part Description PCB Connector CN1 Connector CN2 + CN3 Qty. 1 1 2 Material UL94V-0 (FR-4 or CEM-3) S5B-PH-K SM02(8.0)B-BHS-1-TB Output side CN2: Note t=1m m JST or equal JST or equal Input side CN1: Pin No. CN 1-1 CN 1-2 CN 1-3 CN 1-4 CN 1-5 Symbols Vin GND Vrm t Vbr N.C. Ratings 10.8 ~ 13.2 Vdc 0 ~ 0.4 = OFF / 2.5 ~ Vin = ON 0 ~ 2.5 Vdc - Pin No. CN 2-1 CN 2-2 Pin No. CN 3-1 CN 3-2 Symbols Vhigh Vlow Symbols Vhigh Vlow Ratings 714 Vrm s (7 m Arm s ) (GND) Ratings 714 Vrm s (7 m Arm s ) (GND) Output side CN3: Power Systems – The Power Solution Web: Email: www.Power-Systems.de Info@Power-Systems.de Page (1) Address: Hauptstr. 48 ; 74360 Ilsfeld-Auenstein / Germany Tel. : + 49 / 70 62 / 67 59 - 6 Fax: + 49 / 70 62 / 67 59 - 800 Version 1.6.6, 7th July 2008 All specifications are subject to change without notice. DC-AC INVERTER UNIT PS-DA0201-01(S) (10 W DUAL OUTPUTS) ELECTRICAL CHARACTERISTICS : Conditions Parameters Output Current Output Current Input Current Frequency Open Circuit Voltage No load Shutdow n Symbols Iout Iout Iin F Vopen Ts d Vin (V) 12±1.2 12±0.6 12±1.2 12±1.2 11.4 12±1.2 Vbr (V) Tu (°C) 0.0 2.5 0.0 0.0 0.0 0.0 0 0 0 0 0 ~ +60 ~ +60 ~ +60 ~ +60 ~ +60 Min. 6.5 45 1.300 Specification Typ. 7.0 20 0.88 50 1.500 1.0 Max. 7.5 1.2 55 1.900 Unit m Arm s % Adc kHz Vrm s s ec Note Dut y 10 0% Dut y M in (PRELIMINARY INFORMATION) 0 ~ +60 wit hout load Note 1 : Note 2: Please keep minimum of 2mm clearance (all directions) between inverter high voltage area as marked on mechanical drawing and any conductors. Before apply any control signal into inverter, please provide Vcc first. Please follow the reversed sequence during power off. Power off control signal first, then power off Vcc. TEST CIRCUIT : F Iin V CN1-2 Vrmt 0.4 / 5 Vdc F 1000:1 PROBE Vin 12 V A CN1-1 SW3 CN2-1 Vopen V ~ SW 1 a b CL1 Operation of unit Operation Non operation RL1 a V b SW1 CN1-3 T1 CN2-2 SW4 SW5 A ~ Iout1 CN1-4 Vbr 0 ~ 2.5 Vdc N.C. CN1-5 CN3-1 RL2 CL2 CN3-2 SW6 A ~ Iout2 Power Systems – The Power Solution Web: Email: www.Power-Systems.de Info@Power-Systems.de Page (2) Address: Hauptstr. 48 ; 74360 Ilsfeld-Auenstein / Germany Tel. : + 49 / 70 62 / 67 59 - 6 Fax: + 49 / 70 62 / 67 59 - 800 Version 1.6.6, 7th July 2008 All specifications are subject to change without notice. DC-AC INVERTER UNIT BACKLIGHT INVERTER INSTALLATION INSTRUCTION Precautionary Notes Regarding the Use of This Inverter When using this product, give due consideration to the precautionary notes described below and ensure a safe design. Inappropriate use may result in electric shock, injury or fire. WARNING • This product is subject to high voltage. Do not touch it while the power is on. Failing to do so may result in electric shock. CAUTION • This product is designed for the lighting of a Cold Cathode Fluorescent Lamp. Do not use it with any other load. • Store this product under the conditions defined in the specification document. • Do not store this product in an environment where dust, dirt or corrosive gas (salt, acid, base, etc.) is present. • This product is subject to high voltage. If there is a possibility that the user may touch the product, provide a proper indication in order to draw the user’s attention. • This product is designed for use with general electronic equipment. If it is to be used with medical equipment that directly affects human life or for the control of transportation equipment to which passengers entrust their lives, provide thorough failsafe measures. • Avoid using this product under high temperatures or high humidity or in an environment in which dust, dirt or any corrosive gas (salt, acid, base, etc.) is present. Also, be careful not to allow the formation of dew condensation. It may result in damage or electric shock. • If the product does not have a built-in protective circuit (circuit breaker, fuse, etc.), it is recommended that a fuse be used at the input stage to prevent the generation of smoke or fire in the event of a malfunction. Even when the product has a built-in protective circuit (circuit breaker, fuse, etc.), the circuit may not function properly due to inappropriate operating conditions or power-supply capacity. It is recommended that an appropriate protective circuit (circuit breaker, fuse, etc.) be provided separately from the built-in circuit. • Use the product only within the specified input voltage, output power, output voltage and operating temperature ranges. Exceeding these values may result in damage, etc. Abnormal voltage may result in damage, etc. • Provide a measure for the preventation of surge voltage due to lighting, etc. Abnormal voltage may result in damage, etc. • To prevent problems arising form short-circuiting of the high-voltage section, provide appropriate measures to prevent the entry of foreign substances following installation. • This product is not designed to provide resistance to radiation. HANDLING PRECAUTIONS • This product uses thin wires. Observe the following precautions and handle it with care so as not to cause wire breakage. Broken wire may result in damage, etc. Do not stack multiple products on top of one another, Do not allow the product to come in contact with tools, etc. • Do not apply excessive stress during installation. It may cause chipping and cracking, resulting in damage, etc • Provide a clearance of 2 mm or more between the high-voltage section of this product and the frame body on which the product is installed and also the conductor section (pattern, pad, etc.) Power Systems – The Power Solution Web: Email: www.Power-Systems.de Info@Power-Systems.de Page (1) Address: Hauptstr. 48 ; 74360 Ilsfeld-Auenstein / Germany Tel. : + 49 / 70 62 / 67 59 - 6 Fax: + 49 / 70 62 / 67 59 - 800 Version 2.0, 15th August 2007 All specifications are subject to change without notice. DC-AC INVERTER UNIT Thank you very much for usually patronizing Power Systems and TDK’s DC/AC inverter. Following the expansion of it’s use, there are unexpected troubles that are caused by mis-use or mis-handling because the DC/AC inverter generates a high voltage of 900Vrms or more. Hereafter, the cases of the major troubles are described. Please also refer to “Notes of used” of the attached paper. Ex.1 Multilayered PWB Inverter was mounted the nearest to the main board because there is no surface pattern. However, dielectric breakdown happened because there was a low-voltage pattern in internal layer, and they were damaged by arc fire. Ex.2 Foreign body Short of high voltage area by insect (cockroach etc.) having invaded installed set in food processing plant and counter, etc. Short by adhesion of metal powder when using it by set such as NC machine tool. Ex.3 Mechanical stress Parts will be cracked or the wire of transformer will be broke, etc. When the mechanical stress was given at the installation on the set. Ex.4 Storage, handling When you store it, if the product is piled up or grabed with other inverters together at once, etc. these will be the cause of the break of transformer’s wire and etc. CABLES CONNECTION 1.) Don‘t extand cables. 1.1.) Don‘t cut through nor solder them, unless you have consulted the manufacture. 2.) Don‘t exchange cables. 2.1.) Polarity is very important otherwise -will be able to a short circuit. -there might be a short circuit.(Please refer to fig.1) Fig. 1 OK NG Power Systems – The Power Solution Web: Email: www.Power-Systems.de Info@Power-Systems.de Page (2) Address: Hauptstr. 48 ; 74360 Ilsfeld-Auenstein / Germany Tel. : + 49 / 70 62 / 67 59 - 6 Fax: + 49 / 70 62 / 67 59 - 800 Version 2.0, 15th August 2007 All specifications are subject to change without notice.
PS-DA0201-01S
1. 物料型号: - PCB:1个,材料为UL94V-0(FR-4或CEM-3),厚度为1mm。 - 连接器CN1:1个,型号为S5B-PH-K,兼容JST。 - 连接器CN2 + CN3:2个,型号为SM02(8.0)B-BHS-1-TB,兼容JST。

2. 器件简介: - 该文档描述的是一个低剖面DC到AC逆变器,适用于双灯的LCD,尺寸在6.4到15英寸之间。该逆变器的灯电压为714 Vrms,灯电流为2 x 7 mArms,启动电压为1.500 Vrms(输入电压为12 Vdc)。

3. 引脚分配: - 输入侧CN1: - CN1-1:Vin,电压范围10.8~13.2 Vdc。 - CN1-2:GND。 - CN1-3:Vrmt,0~0.4= OFF/2.5~Vin=ON。 - CN1-4:Vbr,电压范围0 ~2.5 Vdc。 - CN1-5:N.C.(无连接)。 - 输出侧CN2: - CN2-2:Vlow(GND)。 - 输出侧CN3: - CN3-1:Vhigh,电压为714 Vrms(7 mArms)。 - CN3-2:Vlow(GND)。

4. 参数特性: - 输入电压Vin(V):12±1.2 Vdc,输出电流Iout在12±1.2 Vdc时为6.5~7.5 mArms,占空比100%。 - 输入电流Iin在12±1.2 Vdc时为0.88~1.2 Adc。 - 频率F在12±1.2 Vdc时为45~55 kHz。 - 开路电压Vopen在11.4 Vdc时为1.300~1.900 Vrms。

5. 功能详解: - 该逆变器具有远程开关功能、开灯检测功能,并且符合RoHS标准。

6. 应用信息: - 适用于6.4至15英寸双灯型LCD的背光驱动。

7. 封装信息: - 尺寸:长x宽x高为160 x 25 x 10 mm,重量约为24.2克。
PS-DA0201-01S 价格&库存

很抱歉,暂时无法提供与“PS-DA0201-01S”相匹配的价格&库存,您可以联系我们找货

免费人工找货