DC-AC INVERTER UNIT
PS-DA0404-007(S) (20 W QUAD OUTPUTS)
DESCRIPTION : This low profile DC to AC Inverter is developed for quad lamps. Optimized for Sharp: LQ170E1LG11 (PRELIMINARY INFORMATION)
APPLICABLE LCD: 6.4 to 15 inches quad lamp type Lamp Voltage 630 Vrms Lamp Current 6 mArms Lamp Start Up Voltage 1.700 Vrms (Vin : 12 Vdc) FEATURES : Remote ON/OFF Open Lamp Detection RoHS compliant (S) TEMPERATURE & HUMIDITY : Operating Temperature Range Storage Temperature Range Humidity DIMENSIONS : LxWxH 0°C ~ +50°C -20°C ~ +85°C 95 %RH max
160 x 27 x 14 mm
Unit : mm Weight :38,4 (g) typ.
Note: Please use plastic screw in case of a non-insulating mounting base!
Components No. 1 2 3
Part Description PCB Connector CN1 Connector CN2 ~ CN5
Qty. 1 1 4
Material UL94V-0 (FR-4 or CEM-3) 53261-1290 SM02B-BHSS-TB
Output side CN2 ~ CN5
Note t=1m m Molex or equal JST or equal
Input side CN1: Pin No. Symbols Vin CN 1-1 GND CN 1-2 Vrm t CN 1-3 Vbr CN 1-4 CN 1-5 N.C.
Ratings 12 Vdc 0 ~ 0.4 = OFF / 4.5 ~ Vin = ON 0 ~ 3.3 Vdc
Pin No. CN 2-1 CN 2-2
Symbols Vhigh Vlow
Ratings 630 Vrm s (6 m Arm s ) (GND)
Power Systems – The Power Solution
Web: Email: www.Power-Systems.de Info@Power-Systems.de
Page (1)
Address: Hauptstr. 48 ; 74360 Ilsfeld-Auenstein / Germany Tel. : + 49 / 70 62 / 67 59 - 6 Fax: + 49 / 70 62 / 67 59 - 800
Version 1.0.1, 20th April 2007
All specifications are subject to change without notice.
DC-AC INVERTER UNIT
PS-DA0404-007(S) (20 W QUAD OUTPUTS)
ELECTRICAL CHARACTERISTICS :
Parameters Output Current Output Current Input Current Frequency Open Circuit Voltage No load Shutdown Symbols Iout Iout Iin F Vopen Ts d Conditions Vrmt Vin (V) Tu (°C) (V) 12±1.2 5±0.25 0 ~ +50 12±0.6 5±0.25 0 ~ +50 12±1.2 5±0.25 0 ~ +50 12±1.2 5±0.25 0 ~ +50 11.4 5±0.25 0 ~ +50 12±1.2 5±0.25 0 ~ +50 Specification Min. 5.5 2.0 50 1.700 1.0 Typ. 6.0 3.0 1.6 55 Max. 6.5 3.5 2.0 65 Unit m Arm s m Arm s Adc kHz Vrm s s ec Note
V br = 0 V dc V br = 3.3 V dc
(PRELIMINARY INFORMATION)
wit hout load
Note 1 :
Please keep minimum of 2mm clearance (all directions) between inverter high voltage area as marked on mechanical drawing and any conductors.
TEST CIRCUIT :
SW 1 a b Operation of unit Operation Non operation
Power Systems – The Power Solution
Web: Email: www.Power-Systems.de Info@Power-Systems.de
Page (2)
Address: Hauptstr. 48 ; 74360 Ilsfeld-Auenstein / Germany Tel. : + 49 / 70 62 / 67 59 - 6 Fax: + 49 / 70 62 / 67 59 - 800
Version 1.0.1, 20th April 2007
All specifications are subject to change without notice.
很抱歉,暂时无法提供与“PS-DA0404-007”相匹配的价格&库存,您可以联系我们找货