DC-AC INVERTER UNIT
PS-DA0602-01(S) (30 W SIXFOLD OUTPUTS)
DESCRIPTION : This low profile DC to AC Inverter is developed for sextuple lamps. (PRELIMINARY INFORMATION)
APPLICABLE LCD: 15 to 30 inches sextuple lamp type Lamp Voltage 769 Vrms Lamp Current 6 x 6.5 mArms Lamp Start Up Voltage 1.650 Vrms (Vin : 12 Vdc) FEATURES : Remote ON/OFF Open Lamp Detection RoHS compliant (S) TEMPERATURE & HUMIDITY : Operating Temperature Range Storage Temperature Range Humidity DIMENSIONS : LxWxH 0°C ~ +50°C -20°C ~ +85°C 95 %RH max
170 x 60 x 9.5 mm
Pin 1
Pin 1
Pin 1
Pin 1
Pin 1
Pin 1
Pin 1
Pin 1
Unit : mm Weight :64 (g) typ.
Note: Please use plastic screw in case of a non-insulating mounting base!
Components No. 1 2 3 Part Description PCB Connector CN1 Connector CN2 ~ CN7 Qty. 1 1 6 Material UL94V-0 (FR-4 or CEM-3) S8B-PH-SM3-TB SM02B-BHSS-1-TB
Output side CN2 ~ CN7 Pin No. CN 2-1 CN 2-2 Symbols Vhigh Vlow Ratings 769 Vrm s (6.5 m Arm s ) (GND)
Note t=1m m JST or equal JST or equal
Input side CN1: Pin No. Symbols Ratings Vin 12 Vdc CN 1-1+2+3 GND CN 1-4+5+6 Vbr 0 ~ 3.3 Vdc CN 1-7 Vrm t 0 ~ 1.5 = OFF / 2.5 ~ 5.5 = ON CN 1-8
Power Systems – The Power Solution
Web: Email: www.Power-Systems.de Info@Power-Systems.de
Page (1)
Address: Hauptstr. 48 ; 74360 Ilsfeld-Auenstein / Germany Tel. : + 49 / 70 62 / 67 59 - 6 Fax: + 49 / 70 62 / 67 59 - 800
Version 1.4.5, 28th April 2008
All specifications are subject to change without notice.
DC-AC INVERTER UNIT
PS-DA0602-01(S) (30 W SIXFOLD OUTPUTS)
ELECTRICAL CHARACTERISTICS :
Parameters Symbols Conditions Vrmt Vin (V) Tu (°C) (V) 12±1.2 12±0.6 12±1.2 12±1.2 11.4 12±1.2 5±0.25 0 ~ +50 5±0.25 5±0.25 5±0.25 5±0.25 0 0 0 0 ~ +50 ~ +50 ~ +50 ~ +50 Specification Min. 40 1.500 Typ. 6.5 35 2.4 50 1.650 1.0 Max. 7.0 3.4 60 1.900 Unit Note
V in = 12 V d c V d im =0 V Dut y = 100 % V dim = 5.0 V
(PRELIMINARY INFORMATION)
Output Current Output Current Input Current Frequency Open Circuit Voltage No load Shutdow n
Iout Iout Iin F Vopen Ts d
m Arm s % Adc kHz Vrm s s ec
5±0.25 0 ~ +50
wit hout load
Note 1: Note 2:
Please keep minimum of 2mm clearance (all directions) between inverter high voltage area as marked on mechanical drawing and any conductors. Before apply any control signal into inverter, please provide Vcc first. Please follow the reversed sequence during power off. Power off control signal first, then power off Vcc.
TEST CIRCUIT :
F Iin V F
CN2-1
1000:1 PROBE
Vopen
SW3 RL1 CN2-2 CN3-1 SW4 SW5 CL1
V ~
SW 1 a b
Operation of unit Operation Non operation
Vin 12 V
A
CN1-1 CN1-2 CN1-3
A ~
RL2
Iout 1
T1
CN3-2 SW6
A ~
RL3
CL2 Iout 2 CL3 Iout 3
CN1-4 CN1-5 CN1-6
SW7 CN4-1 SW8 CN4-2 CN5-1 RL4 SW9 CL4 Iout 4
A ~
CN1-7 Vbr 0 ~ 3.3 Vdc
CN5-2 SW10 SW11 CN6-1 RL5
A ~
Vrmt 0.4 / 5 Vdc
a
V
b
SW1
CN1-8
CN6-2 SW12 SW13 CN7-1 RL6 CN7-2 SW14
A ~
CL5 Iout 5
A ~
CL6 Iout 6
Dimming Characteristic:
100
Iout (in %)
80 60 40 20 0 0 1 2 3 3,3
Vbr (VDC)
Power Systems – The Power Solution
Web: Email: www.Power-Systems.de Info@Power-Systems.de
Page (2)
Address: Hauptstr. 48 ; 74360 Ilsfeld-Auenstein / Germany Tel. : + 49 / 70 62 / 67 59 - 6 Fax: + 49 / 70 62 / 67 59 - 800
Version 1.4.5, 28th April 2008
All specifications are subject to change without notice.
很抱歉,暂时无法提供与“PS-DA0602-01”相匹配的价格&库存,您可以联系我们找货
免费人工找货