DC-AC INVERTER UNIT
PS-DA0602-057-B(S) (28.5 W SEXTUPLE OUTPUTS)
DESCRIPTION : This low profile DC to AC Inverter is developed for sextuple lamps. Optimized for Sharp: LQ190E1LW41 APPLICABLE LCD: 6.4 to 15 inches sextuple lamp type Lamp Voltage 750 Vrms Lamp Current 6 x 7.5 mArms Lamp Start Up Voltage 1.700 Vrms (Vin : 12 Vdc) FEATURES : Remote ON/OFF Open Lamp Detection RoHS compliant (S) Optimized for max. brightness TEMPERATURE & HUMIDITY : Operating Temperature Range Storage Temperature Range Humidity Pin 1 DIMENSIONS : (PRELIMINARY INFORMATION)
Cable lenghts 50 mm
0°C ~ +50°C -20°C ~ +85°C 95 %RH max
Pin 1
Pin 1
Pin 1
Pin 1
Pin 1 Pin 1
Pin 1
Unit : mm Weight :64 (g) typ.
Note: Please use plastic screw in case of a non-insulating mounting base!
Components No. 1 2 3
Part Description PCB Connector CN1 Connector CN2 ~ CN7
Qty. 1 1 6
Material UL94V-0 (FR-4 or CEM-3) S8B-PH-SM3-TB Aus gangs kabel Nr.14 50m m
Note t=1m m JST or equal Power Sys tem s
Input side CN1: Pin No. Symbols Ratings Vin 12 Vdc CN 1-1+2+3 GND CN 1-4+5+6 Vbr 0 ~ 5 Vdc CN 1-7 Vrm t 0 ~ 1.5 = OFF /2.5 ~ Vin = ON CN 1-8
Output side CN2 ~ CN7 Pin No. Symbols Ratings VHIGH2 750 Vrm s (7.5 m Arm s ) CN 2-1 N.C. CN 2-2 VLOW (GND) CN 2-3
Power Systems – The Power Solution
Web: Email: www.Power-Systems.de Info@Power-Systems.de
Page (1)
Address: Hauptstr. 48 ; 74360 Ilsfeld-Auenstein / Germany Tel. : + 49 / 70 62 / 67 59 - 6 Fax: + 49 / 70 62 / 67 59 - 800
Version 1.1.2, 12th August 2008
All specifications are subject to change without notice.
DC-AC INVERTER UNIT
PS-DA0602-057-B(S) (28.5 W SEXTUPLE OUTPUTS)
ELECTRICAL CHARACTERISTICS :
Parameters Symbols Conditions Vrmt Vin (V) Tu (°C) (V) 12±1.2 12±0.6 12±1.2 12±1.2 11.4 12±1.2 5±0.25 0 ~ +50 5±0.25 5±0.25 5±0.25 5±0.25 0 0 0 0 ~ +50 ~ +50 ~ +50 ~ +50 Specification Min. 7.0 50 1.650 1.0 Typ. 7.5 30 2.35 53 1.700 Max. 8.0 3.05 57 2.000 Unit Note
V in = 12 V dc V dim =0 V D ut y = 10 0% V d im = 5.0 V
(PRELIMINARY INFORMATION)
Output Current Output Current Input Current Frequency Open Circuit Voltage No load Shutdown
Iout Iout Iin F Vopen Ts d
m Arm s % Adc kHz Vrm s s ec
5±0.25 0 ~ +50
wit hout load
Note 1 : Note 2.:
Please keep minimum of 2mm clearance (all directions) between inverter high voltage area as marked on mechanical drawing and any conductors. This inverter could be assembled for the LG: LM190E05 as well. The PCB is designed for both connector sets. The model no. will be set up after the tests.
TEST CIRCUIT :
F Iin V F
CN2-1 1000:1 PROBE
Vopen
SW3 RL1 CN2-2 CN3-1 SW4 SW5 CL1
V ~
SW 1 a
Operation of unit Operation Non operation
Vin 12 V
A
CN1-1 CN1-2 CN1-3
A ~
RL2
Iout 1
b
T1
CN3-2 SW6
A ~
RL3
CL2 Iout 2 CL3 Iout 3
CN1-4 CN1-5 CN1-6
SW7 CN4-1 SW8 CN4-2 CN5-1 RL4 SW9 CL4 Iout 4
A ~
CN1-7 Vbr 0.3 ~ 5 Vdc
CN5-2 SW10 SW11 CN6-1 RL5
A ~
Vrmt 1.5 / 5 Vdc
a
V
b
SW1
CN1-8
CN6-2 SW12 SW13 CN7-1 RL6 CN7-2 SW14
A ~
CL5 Iout 5
A ~
CL6 Iout 6
Dimming Characteristic:
100
80
Iout (in %)
60 40
20
0 0 0,3 1,5 2,6 3,8 5
Vbr (VDC)
Power Systems – The Power Solution
Web: Email: www.Power-Systems.de Info@Power-Systems.de
Page (2)
Address: Hauptstr. 48 ; 74360 Ilsfeld-Auenstein / Germany Tel. : + 49 / 70 62 / 67 59 - 6 Fax: + 49 / 70 62 / 67 59 - 800
Version 1.1.2, 12th August 2008
All specifications are subject to change without notice.
很抱歉,暂时无法提供与“PS-DA0602-057-B”相匹配的价格&库存,您可以联系我们找货