PS-M07D12S4-NJ5R-137 数据手册
DC-AC INVERTER UNIT
PS-M07D12S4-NJ5R-137(S) (6,5 W DUAL OUTPUTS)
DESCRIPTION : This low profile DC to AC Inverter is developed for dual lamps. Optimized for Chi Mei: G104X1-L01 (PRELIMINARY INFORMATION)
APPLICABLE LCD: 6.4 to 12 inches double lamp type Lamp Voltage 460 Vrms Lamp Current 7 mArms Lamp Start Up Voltage 1.300 Vrms (Vin : 12 Vdc) FEATURES : Remote ON/OFF Ext. PWM-Dimming Function RoHS compliant (S) TEMPERATURE & HUMIDITY : Operating Temperature Range Storage Temperature Range Humidity DIMENSIONS :
5 ± 0.5
-10°C ~ +55°C -20°C ~ +85°C 95 %RH max
LxWxH
105 x 22,5 x 10mm
22,5 ± 0.5
15 ± 0.3
CN1
CN2
Unit : mm Weight :20 (g) typ.
10.0MAX
Note: Please use plastic screw in case of a non-insulating mounting base!
Components No. 1 2 3 Part Description PCB Connector CN1 Connector CN2 Qty. 1 1 1 Material UL94V-0 (FR-4 or CEM-3) S5B-PH-SM3 SM03(4.0)B-BHS Output side CN2: Note t=1.6m m JST or equal JST or equal
Input side CN1: Pin No. CN 1-1 CN 1-2 CN 1-3 CN 1-4 CN 1-5 Symbols Vin GND Ext. PWM N.C. Vrm t Ratings 12 Vdc 0 ~ 5 Vdc (L activ) 0 / 5 Vdc (H activ)
Pin No. CN 2-1 CN 2-2 CN 2-3
Symbols VLOW VHIGH1 VHIGH2
Ratings 0Vdc 460Vrm s (7m Arm s ) 460Vrm s (7m Arm s )
Power Systems – The Power Solution
Web: Email: www.Power-Systems.de Info@Power-Systems.de
Page (1)
Address: Hauptstr. 48 ; 74360 Ilsfeld-Auenstein / Germany Tel. : + 49 / 70 62 / 67 59 - 6 Fax: + 49 / 70 62 / 67 59 - 800
Version 1.0, 1st June 2007
All specifications are subject to change without notice.
DC-AC INVERTER UNIT
PS-M07D12S4-NJ5R-137(S) (6,5 W DUAL OUTPUTS)
ELECTRICAL CHARACTERISTICS :
Conditions Vrmt (V) 5±0.25 5±0.25 5±0.25 5±0.25 5±0.25 Specification Min. Typ. Max. 6.5 7.0 7.0 0.7 50 1.300 7.5 8.0 1.2 55 -
(PRELIMINARY INFORMATION)
Parameters Output Current Output Current Input Current Frequency Open Circuit Voltage
Symbols Iout Iout Iin F Vopen
V in (V) 12±0.12 12±1.2 12±1.2 12±1.2 11,4
Tu (°C) -10 ~ +55 -10 -10 -10 -10
Unit m Arm s m Arm s Adc kHz Vrm s
Note
~ +55 6.0 ~ +55 ~ +55 45 ~ +55 1.200
Note 1 : Note 2: Note 3:
Please keep minimum of 2mm clearance (all directions) between inverter high voltage area as marked on mechanical drawing and any conductors. Remote ON/OFF (CN1-5) has priority and can not be used in combination with External PWM Dimming (CN1-3). When 'Ext.PWM' (CN1-3) is used 'Vrmt' (CN1-5) should not be connected. The external PWM frequency should be in a range of 100 ~ 500 Hz. For other frequency please request. The optimum is 250 Hz. Here you will normally not get a interference to the vertical sync. frequency.
F F
1000:1 PROBE
TEST CIRCUIT :
Vin 12 V A Iin V
CN1-1
SW3 CN2-3
Vopen V ~
SW 1 a b
Operation of unit Operation Non operation
CN1-2 T1
SW4 CN2-2
CN1-3 Ext. PWM* 0/5V
RL2 A
RL1 CL2 CL1
NC
CN1-4
~ Iout ~ Iout1 2
SW5 CN2-1
A
Vrmt 2.5 Vdc ~ Vin
a
V
b
SW1
CN1-5
*) Only active when Vrmt is 0 Vdc or floating
EXTERNAL PWM-DIMMING ( Remote ON / OFF Detailed Circuit Diagram ):
Power Systems – The Power Solution
Web: Email: www.Power-Systems.de Info@Power-Systems.de
Page (2)
Address: Hauptstr. 48 ; 74360 Ilsfeld-Auenstein / Germany Tel. : + 49 / 70 62 / 67 59 - 6 Fax: + 49 / 70 62 / 67 59 - 800
Version 1.0, 1st June 2007
All specifications are subject to change without notice.
PS-M07D12S4-NJ5R-137 价格&库存
很抱歉,暂时无法提供与“PS-M07D12S4-NJ5R-137”相匹配的价格&库存,您可以联系我们找货
免费人工找货