F Series
10 WATTS SINGLE & DUAL OUTPUT DC/DC INDUSTRIAL
MODULES
Features
• Metal case and shielded transformer result in very low EMI/RFI • Low ripple • Compact package • PCB mountable • Input/output isolation • Input/output filtering • Proven reliability • Cost effective HV power
Specifications
INPUT Voltage Current Typical turn-on voltage OUTPUT Power Voltage Current Ripple Regulation Isolation Efficiency 10W. See table. See table. See table. 10% (no load to full load). 3,500V + Vout, F80-F121: 500V +Vout. >70% typical. See table. See table. 0.7V.
ENVIRONMENTAL Operating temperature Max case temperature GENERAL Dimensions Weight Packaging OPTIONS Mounting holes, add H to model number. STANDARDS C-Tick AS/NZS CISPR11 Group 1 Class A F01-F60: 71 x 43 x 21 mm. F80-F121: 71 x 43 x 24 mm. 142g. Epoxy encapsulated. –10°C to +50°C. +85°C (measured at point indicated). F80-F121: +70°C (measured at point indicated)
Selection Table
MODEL NUMBER INPUT VOLTAGE INPUT CURRENT NO LOAD INPUT CURRENT FULL LOAD OUTPUT VOLTAGE OUTPUT* CURRENT RIPPLE
F01 F02 F03 F04 F05 F06 F08 F10 F15 F20 F30 F40 F50 F60 F80 F101 F121
0 to 12V 0 to 12V 0 to 12V 0 to 12V 0 to 12V 0 to 12V 0 to 12V 0 to 12V 0 to 12V 0 to 12V 0 to 15V 0 to 15V 0 to 15V 0 to 15V 0 to 15V 0 to 15V 0 to 15V
很抱歉,暂时无法提供与“F06”相匹配的价格&库存,您可以联系我们找货