RAILWAYS
PB169/253/254
1 0 0 - 1 3 8 W AT T S R A I LW AY D C / D C C O N V E R T E R S
Features
• Input reverse polarity protected. • Input transient protected. • Input surge protection. • Meets IEC571, BRB12, BRB13 and BRB18 for input transients and surges
Specifications
INPUT
Voltage PB169: 20-30Vdc. PB253: 18-50Vdc. PB254: 74-138Vdc. 30% of Vin 800V indefinitely.
OPERATING
Efficiency at full load Isolation (with VR1 & VR2 removed) 73%–80% Input – Output: 1000VAC Input – Ground: 1000VAC Output – Ground: 500VAC
Input ripple voltage Input reverse polarity protection
ENVIRONMENTAL
Operating Temperature -20°C to 45°C (PB169, PB253). -10°C to 60°C (PB254).
OUTPUT
Output voltage PB169: 24Vdc. PB253: 24Vdc. PB254: 13.8Vdc. PB169: 4.2A. PB253: 4.2A. PB254: 10A. PB169: 100W. PB253: 100W. PB254: 138W. ±0.36Vdc (PB169/253). ±0.10Vdc (PB254). Input transient and surge protection C-Tick
STANDARDS AND APPROVALS
Designed to meet BRB 12, BRB 13, BRB 18 and IEC571-1. AS/NZS2064:1997 Group 1 Class A
Output current
MECHANICAL
Connections Dimensions 6-way terminal block connector PB169: 60x111x60mm. PB253: 60x111x60mm. PB254: 60x158x205mm. Four M4 slots
Output power
Line & load regulation
Mounting
396
很抱歉,暂时无法提供与“PB169”相匹配的价格&库存,您可以联系我们找货
免费人工找货