VI IAM Input Attenuator Module
FILTER INPUT ATTENUATOR MODULE
MODULES
Features
• • • • • • High surge withstand 97% efficiency Input reverse polarity protected Logic disable Expansion output for arrays UL, CSA, TUV, VDE, BABT, CE, C-Tick
Specifications
INPUT Input voltage High surge withstand Input reverse polarity protection OUTPUT Output power OPERATING Efficiency Isolation MECHANICAL PCB mounting package 58x61x13mm Meets Bellcore and British Telecom EN55022 Level B,FCC Level A
AS/NZS CISPR11 Group 1 Class A
24VDC, 48VDC & 300VDC Meets Bellcore, IEC and British Telecom Yes
PRODUCT GRADE Product Grade C-Grade E-Grade I-Grade M-Grade
Baseplate Operating Temperature -20OC to +100OC -10OC to 100OC -40OC to +100OC -55OC to +100OC
Selection Table
24V Input: 200W 48/300V Input: 400W MODEL NO. VI-A11-CU VI-AWW-CU 97% Input – Output – Baseplate: 1500V rms VI-A33-CQ VI-ANN-CQ VI-A66-CQ MIN. 21VDC 18VDC 42VDC 36VDC 200VDC TYP. 24VDC 24VDC 48VDC 48VDC 300VDC MAX. 32VDC 36VDC 60VDC 76VDC 400VDC POWER 200W 200W 400W 400W 400W
Expansion output for arrays Yes
Note: For RoHS version replace VI with VE.
STANDARDS AND APPROVALS EMI/RFI C-Tick Safety standard Transient protection
UL544, CSA C22.2 No. 950, TÜV IEC950, VDE EN60950 IEC61000-4-5 Level 2,British Telecom BTR2511
Typical Configuration Not for design use; see data sheet.
Your dependable power partner – www.powerbox.com.au
243
很抱歉,暂时无法提供与“VI-AWW-CU”相匹配的价格&库存,您可以联系我们找货
免费人工找货