M57140-01
Powerex, Inc., 200 Hillis Street, Youngwood, Pennsylvania 15697-1800 (724) 925-7272
Isolated
DC-to-DC Converter
H
TERMINAL NUMBER
1
14
2
13
3
F
12
11
J
10
9
E
4
5
8
6
7
G
B
D
C
A
14
4, 5, 6
13
12
INPUT
DC 20V
11
PUSH-PULL
CONVERTER
CONTROL CIRCUIT
10
9
1, 2, 3
8
7
+
OUT PUT
– 15V, 30mA
+
OUT PUT
– 15V, 30mA
+
OUT PUT
– 15V, 30mA
+
OUT PUT
– 15V, 100mA
Features:
□ Output Specification:
+15V x 4, Total 3W max.
□ Primary-to-secondary Isolation:
2500 VRMS, One Minute
□ Secondary-to-secondary
Isolation Voltage:
1500 VRMS, One Minute
□ Compact, Low Profile Design
Outline Drawing and Circuit Diagram
Millimeters
Description:
M57140-01 is an isolated DC-to-DC
converter designed to drive IPMs
(Intelligent Power Modules). With
an input of DC 20V, the module
supplies four 15V outputs. Isolation is provided from primary to
secondary and also between the
secondaries. Interwinding isolation
is designed for driving the IPM.
Dimensions
Inches
Dimensions
Inches
Millimeters
A
2.03
51.5
F
0.02
0.55
B
0.71
18.0
G
0.08
2.1
C
.39±.06
12.5±1.5
H
0.08
2.1
D
.18±.06
4.5±1.5
J
1.13
28.8
E
0.07
1.8
Applications:
□ IPMs for General Purpose
Inverter and AC Servo
□ Power Source for MOSFET
Driving Circuits
Ordering Information:
M57140-01
159
Powerex, Inc., 200 Hillis Street, Youngwood, Pennsylvania 15697-1800 (724) 925-7272
M57140-01
Isolated
DC-to-DC Converter
Absolute Maximum Ratings, VIN = 20V, Ta = 25 °C unless otherwise specified
Characteristics
Symbol
Input Voltage
VIN
Terminals 4 , 5 , 6 - 1 , 2 , 3
Test Conditions
M57140-01
Load Current
IL
Terminals 14 - 13 , 12 - 11 , 10 - 9
Units
25
Terminals 8 - 7
Volts
30
mA
100
mA
Operating Temperature
Topr
There Should be
-10 ~ +75
°C
Storage Temperature
Tstg
No Condensation
-20 ~ +85
°C
Internal Power Dissipation
Pd
–
1.5
Watts
Primary-to-Secondary Isolation
1 Minute
2500
Vrms
Secondary-to-Secondary Isolation
1 Minute
1500
Vrms
Electrical Characteristics, VIN = 20V, Ta = 25 °C unless otherwise specified
Characteristics
Input Source Voltage
Output Voltage
Symbol
Test Conditions
Min.
VIN
Direct Current
18
VO
Between Pins 10 - 9 , 12 - 11, 14 - 13,
13.5
Typ.
Max.
Units
20
22
Volts
15.0
16.5
Volts
15.0
16.5
Volts
–
mA
IL = 30mA
Peak Load Current
Load Regulation
ILP
Reg-out
Between Pins 8 - 7 , IL = 100mA
13.5
Between Pins 10 - 9 , 12 - 11, 14 - 13
–
33
Between Pins 8 - 7
–
110
–
mA
–
5
10
%
Between Pins 8 - 7 , IL = 0 ~ 100mA
–
7
12
%
Between Pins 10 - 9 , 12 - 11, 14 - 13,
–
70
–
%
–
70
–
%
Between Pins 10 - 9 , 12 - 11, 14 - 13,
IL = 0 ~ 30mA
Efficiency
h
IL = 30mA
Between Pins 8 - 7 , IL = 100mA
Application Circuit
8
+
33µF
IL VC
7
4, 5, 6
10
+
10µF
IL VC
9
+
M57140-01
VIN = 20V 330µF
12
+
1, 2, 3
10µF
IL VC
11
14
+
10µF
13
160
IL VC
Powerex, Inc., 200 Hillis Street, Youngwood, Pennsylvania 15697-1800 (724) 925-7272
M57140-01
Isolated
DC-to-DC Converter
Application Circuit
P
R
+
C
AMP
SG
U
14
13
+15
11 , 12
INPUT
DC113V-380V
2.2µF
+
5
+15
4, 5, 6
+ 50V
330µF
M57120L-01
12
0
0
R
V
10
+15
M57140-01
+
C
9
2
AMP
SG
0
1, 2, 3
6
AMP
SG
11
R
1
+
C
+ 50V
47µF
W
8
+15
0
AMP
7
SG
R
+
C
AMP
SG
R – TO STABILIZE WHEN NOT LOADED
C – TO SMOOTH OUTPUT VOLTAGE
AMP
SG
IPM
N
Handling Precautions:
• When M57140-01 is used under excessive load condition, output side rectifying diodes will be destroyed.
Care should be exercised so as not to operate the device above the rated maximum load current.
• Coating Materials should not be applied on this device because the application of coating materials for
waterproofing could cause a stress and destroy a device.
161
Powerex, Inc., 200 Hillis Street, Youngwood, Pennsylvania 15697-1800 (724) 925-7272
M57140-01
Isolated
DC-to-DC Converter
OUTPUT VOLTAGE LOAD CURRENT CHARACTERISTICS
BETWEEN TERMINALS 8 AND 7
OUTPUT VOLTAGE -LOAD CURRENT
CHARACTERISTICS BETWEEN
TERMINALS 10 - 9 , 12 - 11 , 14 - 13
17
INPUT CURRENT - OUTPUT POWER
0.3
17
Ta = 60°C
25°C
15
0°C
VIN = 20V
CONDITION:
OTHER OUTPUT
TERMINALS ARE
NOT LOADED
14
0
16
INPUT CURRENT, IIN, (mA)
16
OUTPUT VOLTAGE, Vo, (VOLTS)
OUTPUT VOLTAGE, Vo, (VOLTS)
VIN = 20V
Ta = 60°C
15
0°C, 25°C
VIN = 20V
CONDITION:
TERMINALS
8 AND 7 ARE
NOT LOADED
14
20
40
60
80
100
25°C
0.1
60°C
0
0
0
Ta = 0°C
0.2
0
10
LOAD CURRENT, IL, (mA)
20
0
30
OUTPUT VOLTAGE
VS AMBIENT TEMPERATURE
BETWEEN TERMINALS 8 AND
OUTPUT VOLTAGE VS
AMBIENT TEMPERATURE BETWEEN
TERMINALS 10 - 9 , 12 - 11 , 14 - 13
7
20
8
VIN = 20V
CONDITION:
OTHER OUTPUT
TERMINALS ARE
NOT LOADED
4
0
-20
0
20
40
60
16
Ta = 25°C
VIN = 20V
60
12
8
VIN = 20V
CONDITION:
TERMINALS
8 AND 7 ARE
NOT LOADED
4
0
-20
80
AMBIENT TEMPERATURE, Ta, (°C)
OUTPUT VOLTAGE
VS INPUT VOLTAGE
BETWEEN TERMINALS 8 AND
20
40
60
80
IL = 0mA
16
13
14
IL = 100mA
12
10
18
IL = 0mA
16
30mA
14
12
10
0
0
0
18
19
20
21
INPUT VOLTAGE, VIN, (VOLTS)
22
23
0
18
19
20
21
INPUT VOLTAGE, VIN, (VOLTS)
22
0
1
2
3
TOTAL OUTPUT POWER, Po, (WATTS)
Ta = 25°C
OUTPUT VOLTAGE, Vo, (VOLTS)
OUTPUT VOLTAGE, Vo, (VOLTS)
Ta = 25°C
162
0
0
20
18
40
20
OUTPUT VOLTAGE VS
INPUT VOLTAGE BETWEEN
TERMINALS 10 - 9 , 12 - 11 , 14 -
7
50
30
AMBIENT TEMPERATURE, Ta, (°C)
20
4
IL = 30mA
EFFICIENCY, , (%)
OUTPUT VOLTAGE, Vo, (VOLTS)
OUTPUT VOLTAGE, Vo, (VOLTS)
12
3
80
70
IL = 100mA
2
EFFICIENCY CHARACTERISTICS
20
16
1
OUTPUT POWER, Po, (WATTS)
LOAD CURRENT, IL, (mA)
23