LNK3202/3204-6, LNK3294 & LNK3296
LinkSwitch-TN2 Family
Highly Energy Efficient Off-line Switcher IC with Integrated System
Level Protection for Low Component-Count Power Supplies
Product Highlights
Highest Performance and Design Flexibility
•
•
•
•
Supports buck, buck-boost and flyback topologies
Excellent load and line regulation
Selectable device current limit
66 kHz operation with accurate current limit
• Allows the use of low-cost off-the-shelf inductors
• Reduces size and cost of magnetics and output capacitor
• Frequency jittering reduces EMI filter complexity
• Pin-out simplifies PCB heat sinking
Enhanced Safety and Reliability Features
•
•
•
•
•
Auto-restart for short-circuit and open loop faults
Output overvoltage protection (OVP)
Line input overvoltage protection (OVL)
Hysteretic over-temperature protection (OTP)
Extended creepage between DRAIN pin and all other pins improves
field reliability
• 725 V MOSFET rating for excellent surge withstand
• 900 V MOSFET rating series for industrial or extra safety margin
EcoSmart™– Extremely Energy Efficient
•
•
•
•
Standby supply current VIN or VO < VIN
4. Optocoupler feedback
- Accuracy only limited by reference choice
- Low cost non-safety rated optocoupler
- No pre-load required
5. Fail-safe – output is not subjected to input
voltage if the internal power MOSFET fails
6. Minimum no-load consumption
Table 3 (cont). Common Circuit Configurations using LinkSwitch-TN2.
LinkSwitch-TN2 Layout Considerations
In the buck or buck-boost converter configuration, since the SOURCE
pins in LinkSwitch-TN2 are switching nodes, the copper area
connected to SOURCE should be minimized to minimize EMI within
the thermal constraints of the design.
In the boost configuration, since the SOURCE pins are tied to DC
return, the copper area connected to SOURCE can be maximized to
improve heat sinking.
Figures 9a, 9b and 9c are printed circuit board layout design
examples for the circuit schematic shown in Figure 8. The loop
formed between the LinkSwitch-TN2, inductor (L1), freewheeling
diode (D1), and output capacitor (C2) should be kept as small as
possible. The BYPASS pin capacitor C1 should be located physically
close to the SOURCE (S) and BYPASS (BP) pins. To minimize direct
coupling from switching nodes, the LinkSwitch-TN2 should be placed
away from AC input lines. It may be advantageous to place capacitors
C4 and C5 in-between LinkSwitch-TN2 and the AC input. The second
rectifier diode D4 is optional, but may be included for better EMI
performance and higher line surge withstand capability.
Figure 9a. Recommended Printed Circuit Layout for LinkSwitch-TN2 using P Package.
8
Rev. G 02/19
www.power.com
LinkSwitch-TN2
Figure 9b. Recommended Printed Circuit Layout for LinkSwitch-TN2 using G Package.
Figure 9c. Recommended Printed Circuit Layout for LinkSwitch-TN2 using D Package.
9
www.power.com
Rev. G 02/19
LinkSwitch-TN2
Quick Design Checklist
As with any power supply design, all LinkSwitch-TN2 designs should
be verified for proper functionality on the bench. The following
minimum tests are recommended:
1. Adequate DC Rail Voltage – Check that the minimum DC input
voltage does not fall below 70 VDC at maximum load, minimum
input voltage.
2. Correct Diode Selection – UF400x series diodes with reverse
recovery time of 75 ns or better are recommended only for
designs that operate in MDCM at an ambient of 70 °C or below.
For designs operating in continuous conduction mode (CCM) and/
or higher ambients, then a diode with a reverse recovery time of
35 ns or better, such as the BYV26C, is recommended.
3. Maximum Drain Current – Verify that the peak drain current is
below the data sheet peak drain specification under worst-case
conditions of highest line voltage, maximum overload (just prior
to auto-restart) and highest ambient temperature.
4. Thermal Check – At maximum output power, minimum input
voltage and maximum ambient temperature, verify that the
LinkSwitch-TN2 SOURCE pin temperature is 100 °C or below.
This ensures adequate margin due to variations in RDS(ON) from
part to part. If the device temperature of the IC exceeds 85 °C
with ambient temperature of 25 °C, it is recommended the next
bigger device in the family should be selected for the application.
A battery powered thermocouple meter is recommended to make
measurements when the SOURCE pins are a switching node.
Alternatively, the ambient temperature may be raised to indicate
margin to thermal shutdown.
In a LinkSwitch-TN2 design using a buck or buck-boost converter
topology, the SOURCE pin is a switching node. Oscilloscope measurements should therefore be made with probe grounded to a DC voltage,
such as primary return or DC input rail, and not to the SOURCE pins.
The power supply input must always be supplied from an isolated
source when doing measurements (e.g. via an isolation transformer).
10
Rev. G 02/19
www.power.com
LinkSwitch-TN2
Absolute Maximum Ratings(1,5)
DRAIN Pin Voltage:.LNK320x.........................................-0.3 to 725 V
.LNK329x.........................................-0.3 to 900 V
DRAIN Pin Peak Current: LNK3202........................................600 mA2
LNK3204......................................1230 mA2
LNK3205......................................2460 mA2
LNK3206......................................3750 mA2
LNK3294........................................968 mA2
LNK3296......................................3194 mA2
FEEDBACK Pin Voltage................................................... -0.3 V to 7 V
FEEDBACK Pin Current...........................................................100 mA
BYPASS Pin Voltage....................................................... -0.3 V to 7 V
Storage Temperature ..............................................-65 °C to 150 °C
Operating Junction Temperature3 .............................-40 °C to 150 °C
Lead Temperature4 ................................................................ 260 °C
Notes:
1. All voltages referenced to SOURCE, TA = 25 °C.
2. See Figure 15 and Figure 25, for VDS > 400 V.
3. Normally limited by internal circuitry.
4. 1/16 in. from case for 5 seconds.
5. Maximum ratings specified may be applied, one at a time,
without causing permanent damage to the product.
Exposure to Absolute Maximum Rating conditions for
extended periods of time may affect product reliability.
Thermal Resistance
Thermal Resistance: P or G Package:
(qJA) ........................................ 70 °C/W2; 60 °C/W3
(qJC)1 ........................................................ 11 °C/W
D Package:
(qJA) ......................................100 °C/W(2; 80 °C/W3
(qJC)1 ........................................................ 30 °C/W
Parameter
Symbol
Notes:
1. Measured on pin 8 (SOURCE) close to plastic interface.
2. Soldered to 0.36 sq. in. (232 mm2), 2 oz. (610 g/m2) copper clad.
3. Soldered to 1 sq. in. (645 mm2), 2 oz. (610 g/m2) copper clad.
Conditions
SOURCE = 0 V; TJ = -40 to 125 °C
See Figure 10
(Unless Otherwise Specified)
Min
Typ
Max
62
66
70
Units
Control Functions
Output
Frequency
fOSC
TJ = 25 °C
Maximum Duty Cycle
DCMAX
S2 Open
FEEDBACK Pin Turnoff
Threshold Current
IFB
FEEDBACK Pin Voltage
at Turnoff Threshold
FEEDBACK Pin Instant
Shutdown Current
Peak-Peak Jitter
4
kHz
LNK320x
66
69
73
LNK329x
65
68
72
VBP = 5.0 V to 5.5 V
TJ = 25 °C
44
49
54
mA
VFB
VBP = 5.0 V to 5.5 V
TJ = 25 °C
1.97
2.00
2.03
V
IFB(SD)
TJ = 25 °C
520
675
800
mA
FEEDBACK Pin Instant
Shutdown Delay
FEEDBACK Pin Voltage
at Shutdown Current
Average
%
TJ = 25 °C
2
Switch
Cycles
VFB(SD)
VBP = 5.0 V to 5.5 V
TJ = 25 °C
3.3
V
IS1
VFB = 2.1 V
(MOSFET Not Switching)
See Note A
75
mA
DRAIN Pin
Supply Current
IS2
FEEDBACK Open
(MOSFET
Switching)
See Notes A, B
LNK3202
98
LNK3204
113
LNK3205
141
LNK3206
165
LNK3294
120
LNK3296
225
mA
11
www.power.com
Rev. G 02/19
LinkSwitch-TN2
Parameter
Symbol
Conditions
SOURCE = 0 V; TJ = -40 to 125 °C
See Figure 10
(Unless Otherwise Specified)
Min
Typ
Max
ICH1
VBP = 0 V
TJ = 25 °C
-11
-7
-3
ICH2
VBP = 4 V
TJ = 25 °C
-7.5
-5
-2.5
4.7
5.0
5.2
V
6
8
mA
4.95
5.2
5.45
V
0.37
0.47
0.57
V
Units
Control Functions (cont.)
BYPASS Pin
Charge Current
BYPASS Pin Voltage
BYPASS Pin Shutdown
Threshold Current
BYPASS Pin
Shunt Voltage
mA
VBP
IBP(SD)
TJ = 25 °C
VBP(SHUNT)
IBP = 2 mA
BYPASS Pin
Voltage Hysteresis
VBP(H)
BYPASS Pin
Supply Current
IBP(SC)
See Note C
55
mA
Circuit Protection
di/dt = 55 mA/ms
TJ = 25 °C
di/dt = 250 mA/ms
TJ = 25 °C
di/dt = 65 mA/ms
TJ = 25 °C
di/dt = 415 mA/ms
TJ = 25 °C
di/dt = 75 mA/ms
TJ = 25 °C
Standard Current Limit
(CBP = 0.1 mF,
See Note D, H)
ILIMIT
di/dt = 500 mA/ms
TJ = 25 °C
di/dt = 95 mA/ms
TJ = 25 °C
di/dt = 610 mA/ms
TJ = 25 °C
di/dt = 65 mA/ms
TJ = 25 °C
di/dt = 415 mA/ms
TJ = 25 °C
di/dt = 95 mA/ms
TJ = 25 °C
di/dt = 610 mA/ms
TJ = 25 °C
Reduced Current Limit
(CBP = 1 mF,
See Note D, H)
ILIMIT(RED)
di/dt = 28 mA/ms
TJ = 25 °C
di/dt = 170 mA/ms
TJ = 25 °C
126
136
146
149
170
191
240
257
275
278
317
356
350
375
401
394
448
502
450
482
515
510
580
650
240
257
275
278
317
356
450
482
515
510
580
650
70
80
90
104
119
134
LNK3202
LNK3204
LNK3205
mA
LNK3206
LNK3294
LNK3296
LNK3202
mA
12
Rev. G 02/19
www.power.com
LinkSwitch-TN2
Parameter
Symbol
Conditions
SOURCE = 0 V; TJ = -40 to 125 °C
See Figure 10
(Unless Otherwise Specified)
Min
Typ
Max
180
205
230
227
258
289
227
259
291
292
332
372
325
370
415
Units
Circuit Protection (cont.)
di/dt = 65 mA/ms
TJ = 25 °C
di/dt = 415 mA/ms
TJ = 25 °C
di/dt = 75 mA/ms
TJ = 25 °C
di/dt = 500 mA/ms
TJ = 25 °C
Reduced Current Limit
(CBP = 1 mF,
See Note D, H)
ILIMIT(RED)
di/dt = 95 mA/ms
TJ = 25 °C
di/dt = 610 mA/ms
TJ = 25 °C
LNK3206
mA
464
520
180
205
230
227
258
289
325
370
415
408
464
520
LNK3202
See Note I
373
534
687
LNK3204
See Note I
356
475
594
LNK3205
See Note I
412
531
650
LNK3206
See Note I
442
591
734
LNK3294
See Note I
356
480
599
LNK3296
See Note I
350
550
760
di/dt = 415 mA/ms
TJ = 25 °C
di/dt = 95 mA/ms
TJ = 25 °C
di/dt = 610 mA/ms
TJ = 25 °C
tON(MIN)
LNK3205
408
di/dt = 65 mA/ms
TJ = 25 °C
Minimum On-Time
LNK3204
LNK3294
LNK3296
ns
Leading Edge
Blanking Time
tLEB
TJ = 25 °C
See Note E
300
450
Thermal Shutdown
Temperature
TSD
See Note F
135
142
Thermal Shutdown
Hysteresis
TSDH
See Note F
Internal Soft-Start
fOSC(CC)
LNK329x
ns
150
°C
75
°C
Soft-Start Period, See Note E
256
Cycles
Soft-Start Frequency
33
kHz
13
www.power.com
Rev. G 02/19
LinkSwitch-TN2
Parameter
Symbol
Conditions
SOURCE = 0 V; TJ = -40 to 125 °C
See Figure 10
(Unless Otherwise Specified)
Min
Typ
Max
TJ = 25 °C
48
55.2
TJ = 100 °C
76
88.4
TJ = 25 °C
24
27.6
TJ = 100 °C
38
44.2
TJ = 25 °C
12
13.8
TJ = 100 °C
19
22.1
TJ = 25 °C
7
8.1
TJ = 100 °C
11
12.9
TJ = 25 °C
17
19.6
TJ = 100 °C
27
31
TJ = 25 °C
5.3
6.1
TJ = 100 °C
8.4
9.7
Units
Output
LNK3202
ID = 13 mA
LNK3204
ID = 25 mA
ON-State
Resistance
LNK3205
ID = 35 mA
RDS(ON)
LNK3206
ID = 45 mA
LNK3294
ID = XX mA
LNK3296
ID = XX mA
OFF-State Drain
Leakage Current
Breakdown Voltage
IDSS
BVDSS
LNK3202/3204
50
LNK3205
70
LNK3206
90
LNK3294
50
LNK3296
50
VBP = 5.4 V
VFB ≥2.1 V
VDS = 80% BVDSS
TJ = 25 °C
VBP = 5.4 V
VFB ≥2.1 V
TJ = 25 °C
DRAIN Pin
Supply Voltage
LNK320X
725
LNK329X
900
TJ = 25 °C
Auto-Restart
ON-Time
t AR(ON)
Auto-Restart
OFF-Time
t AR(OFF)
Auto-Restart
Duty Cycle
DC AR
TJ = 25 °C
See Note G
TJ = 25 °C
See Note G
mA
V
50
V
50
First Off Period
150
Subsequent Periods
1500
Subsequent Periods
W
3
ms
ms
%
14
Rev. G 02/19
www.power.com
LinkSwitch-TN2
Notes:
A. Total current consumption is the sum of IS1 and IDSS when FEEDBACK pin voltage is = 2.1 V (MOSFET not switching) and the sum of IS2 and
IDSS when FEEDBACK pin is shorted to SOURCE (MOSFET switching).
B. Since the output MOSFET is switching, it is difficult to isolate the switching current from the supply current at the DRAIN. An alternative is
to measure the BYPASS pin current at 5.1 V.
C. This current is only intended to supply an optional optocoupler connected between the BYPASS and FEEDBACK pins and not any other
external circuitry.
D. For current limit at other di/dt values, refer to Figures 21 and 22.
E. This parameter is guaranteed by design.
F. This parameter is derived from characterization.
G. Auto-restart on time has the same temperature characteristics as the oscillator (inversely proportional to frequency).
H. The BP/M capacitor value tolerance should be equal or better than indicated below across the ambient temperature range of the target
application.
I. Measured using circuit in Figure 12 with 50 W drain pull-up. The width of the drain pulse is measured as the time from VFALL = 42 V to
VRISE = 40 V (VDR = 50 V), for LNK32x6/x5/x4 and as the time from VFALL = 32 V to VRISE = 30 V on rising edge (VDR = 35 V), for LNK3202.
Nominal BP/M Pin
Capacitor Value
Tolerance Relative to
Minimal Capacitor Value
Min
Max
0.1 mF
-60%
+100%
1 mF
-50%
+100%
15
www.power.com
Rev. G 02/19
LinkSwitch-TN2
470 kΩ
470 Ω
5W
S2
S1
BP/M
FB
D
50 V
50 V
0.1 µF
S
S
S
S
PI-7850-033016
Figure 10. LinkSwitch-TN2 General Test Circuit.
50 Ω
FB
D
BP/M
S
0.1 µF
VDR
PI-7899-031816
Figure 12. LinkSwitch-TN2 Minimum On-Time Test Circuit.
Figure 11. LinkSwitch-TN2 Duty Cycle Measurement.
T1
VDR
VFALL
T2
VRISE
TON_MIN = T2 - T1
0V
PI-7898-031716
Figure 13. LinkSwitch-TN2 Minimum On-Time Measurement.
16
Rev. G 02/19
www.power.com
LinkSwitch-TN2
1.0
0.7
Scaling Factors:
LNK3202: 1.00
LNK3204: 2.05
LNK3205: 4.10
LNK3206: 6.25
0.6
Drian Current IDS (A)
PI-2213-012301
0.5
0.4
0.3
0.2
0.1
0
0.9
-50 -25
0
25
50
0
75 100 125 150
Drain Voltage VDS (V)
Junction Temperature (°C)
Figure 15. Maximum Allowable Drain Current vs. Drain Voltage.
PI-7851-102716
Drain Current IDS (A)
0.30
25 °C
0.20
100 °C
0.15
0.10
Scaling Factors:
LNK3202 1.00
LNK3204 2.05
LNK3205 4.10
LNK3206 6.25
0.05
0
0
2
4
6
8
1000
Drain Capacitance (pF)
Figure 14. Breakdown vs. Temperature.
0.25
Scaling Factors:
LNK3202 1.00
LNK3204 2.05
LNK3205 4.10
LNK3206 6.25
100
10
1
10 12 14 16 18 20
0
1.0
0.8
0.6
0.0
-50
Normalized ILIM = 1
Scaling Factors:
LNK3202 55 mA/µs
LNK3204 65 mA/µs
LNK3205 75 mA/µs
LNK3206 95 mA/µs
136
257
375
482
0
100
50
mA
mA
mA
mA
Junction Temperature (˚C)
Figure 18. Current Limit vs. Temperature.
150
1.2
PI-8111-092916
PI-8112-092916
Default Current Limit at Low di/dt
(Normalized to 25 ˚C)
1.2
Default Current Limit at High di/dt
(Normalized to 25 ˚C)
Figure 17. COSS vs. Drain Voltage.
Figure 16. Output Characteristics.
0.2
50 100 150 200 250 300 350 400 450
Drain Voltage (V)
Drain Voltage VDS (V)
0.4
100 200 300 400 500 600 700 800
PI-7853-071316
Breakdown Voltage
(Normalized to 25 °C)
1.1
PI-7932-092716
Typical Performance Characteristics
1.0
0.8
0.6
Normalized ILIM = 1
Scaling Factors:
LNK3202 250 mA/µs
LNK3204 415 mA/µs
LNK3205 500 mA/µs
LNK3206 580 mA/µs
0.4
0.2
0.0
-50
0
50
170
317
448
580
mA
mA
mA
mA
100
150
Junction Temperature (˚C)
Figure 19. Current Limit vs. Temperature.
17
www.power.com
Rev. G 02/19
LinkSwitch-TN2
Typical Performance Characteristics
Normalized Current Limit
1.0
0.8
0.6
0.4
0.2
0.0
-50
0
50
100
1.2
1.0
0.8
0.6
Scaling
Factors:
Normalized Normalized
di/dt = 1
ILIM = 1
0.4
LNK3202
LNK3204
LNK3205
LNK3206
55
65
75
95
0.2
0.0
150
PI-8114-092916
1.4
PI-8113-092716
Output Frequency
(Normalized to 25 ˚C)
1.2
1
2
136
257
375
482
4
mA
mA
mA
mA
5
6
Normalized di/dt
Junction Temperature (˚C)
Figure 21. Default Current Limit vs. di/dt.
Figure 20. Output Frequency vs. Junction Temperature.
PI-8115-092916
1.4
Normalized Current Limit
3
mA/µs
mA/µs
mA/µs
mA/µs
1.2
1.0
0.8
0.6
Scaling
Factors:
Normalized Normalized
di/dt = 1
ILIM = 1
0.4
LNK3202
LNK3204
LNK3205
LNK3206
28
65
75
95
0.2
0.0
1
2
3
mA/µs
mA/µs
mA/µs
mA/µs
80
205
259
370
4
mA
mA
mA
mA
5
6
Normalized di/dt
Figure 22. Reduced Current Limit vs. di/dt.
18
Rev. G 02/19
www.power.com
LinkSwitch-TN2
1.0
0.6
Drain Current IDS (A)
Scaling Factors:
LNK3294 1.0
LNK3296 3.3
PI-8830-092618
Drain Current IDS (A)
1.2
0.8
0.6
0.4
0.2
0
0
Scaling Factors:
LNK3294 1.0
LNK3296 3.3
0.5
25 °C
0.4
100 °C
0.3
0.2
0.1
0
125 250 375 500 625 750 875 1000
0
5
Drain Voltage VDS (V)
10
15
20
Drain Voltage VDS (V)
10000
Scaling Factors:
LNK3294 1.0
LNK3296 3.3
1000
PI-8832-021419
Figure 24. Output Characteristics.
Figure 23. Maximum Allowable Drain Current vs. Drain Voltage.
Drain Capacitance (pF)
PI-8831-092618
Typical Performance Characteristics 900 V
100
10
1
0
100
200
300
400
500
Drain Voltage (V)
Figure 25. COSS vs. Drain Voltage.
19
www.power.com
Rev. G 02/19
LinkSwitch-TN2
1.0
0.8
0.6
Scaling
Factors:
Normalized Normalized
di/dt = 1
ILIM = 1
0.4
LNK3294
LNK3296
65 mA/µs
95 mA/µs
250 mA
480 mA
0.2
0.0
1
2
3
4
5
6
1.4
PI-8914-020719
1.2
Normalized Standard Current Limit
1.4
PI-8913-020719
Normalized Standard Current Limit
Typical Performance Characteristics 900 V
1.2
1.0
0.8
0.6
Scaling
Factors:
Normalized Normalized
di/dt = 1
ILIM = 1
0.4
LNK3294
LNK3296
65 mA/µs
95 mA/µs
197 mA
368 mA
0.2
0.0
7
1
2
3
4
5
6
Figure 26. Normalized Current Limit vs. di/dt.
Figure 27. Normalized Current Limit vs. di/dt.
0.8
0.6
0.4
Scaling
Factors:
Normalized ILIM = 1
LNK3294
LNK3296
65 mA/µs
95 mA/µs
250 mA
480 mA
0.2
0.0
-50 -30 -10 10 30 50 70 90 110 130 150
1.2
1.0
0.8
0.6
0.4
Normalized ILIM = 1
LNK3294
LNK3296
65 mA/µs
95 mA/µs
197 mA
368 mA
0.2
0.0
-50 -30 -10 10 30 50 70 90 110 130 150
Junction Temperature (°C)
Figure 30. Reduced Current Limit at Low Ramp Rate.
Reduced Current Limit at High di/dt
(Normalized to 25 °C)
PI-8917-020719
Reduced Current Limit at Low di/dt
(Normalized to 25 °C)
0.4
Scaling
Factors:
283 mA
577 mA
0.0
-50 -30 -10 10 30 50 70 90 110 130 150
Figure 29. Standard Current Limit at High Ramp Rate.
0.8
0.6
415 mA/µs
610 mA/µs
Junction Temperature (°C)
Figure 28. Standard Current Limit at Low Ramp Rate.
1.0
Normalized ILIM = 1
LNK3294
LNK3296
0.2
Junction Temperature (°C)
1.2
Scaling
Factors:
1.2
PI-8918-020719
1.0
7
PI-8916-020719
PI-8915-020719
1.2
Default Current Limit at High di/dt
(Normalized to 25 °C)
Normalized di/dt
Default Current Limit at Low di/dt
(Normalized to 25 °C)
Normalized di/dt
1.0
0.8
0.6
0.4
Scaling
Factors:
Normalized ILIM = 1
LNK3294
LNK3296
415 mA/µs
610 mA/µs
225 mA
460 mA
0.2
0.0
-50 -30 -10 10 30 50 70 90 110 130 150
Junction Temperature (°C)
Figure 31. Reduced Current Limit at High Ramp Rate.
20
Rev. G 02/19
www.power.com
LinkSwitch-TN2
PDIP-8C (P Package)
-E-
⊕ D S .004 (.10)
.240 (6.10)
.260 (6.60)
Pin 1
-D-
.356 (9.05)
.387 (9.83)
.057 (1.45)
.068 (1.73)
(NOTE 6)
.125 (3.18)
.145 (3.68)
-T-
Notes:
1. Package dimensions conform to JEDEC specification
MS-001-AB (Issue B 7/85) for standard dual-in-line (DIP)
package with .300 inch row spacing.
2. Controlling dimensions are inches. Millimeter sizes are
shown in parentheses.
3. Dimensions shown do not include mold flash or other
protrusions. Mold flash or protrusions shall not exceed
.006 (.15) on any side.
4. Pin locations start with Pin 1, and continue counter-clockwise to Pin 8 when viewed from the top. The notch and/or
dimple are aids in locating Pin 1. Pin 3 is omitted.
5. Minimum metal to metal spacing at the package body for
the omitted lead location is .137 inch (3.48 mm).
6. Lead width measured at package body.
7. Lead spacing measured with the leads constrained to be
perpendicular to plane T.
.015 (.38)
MINIMUM
SEATING
PLANE
.008 (.20)
.015 (.38)
.118 (3.00)
.140 (3.56)
.100 (2.54) BSC
.014 (.36)
.022 (.56)
.048 (1.22)
.053 (1.35)
⊕T
.300 (7.62) BSC
(NOTE 7)
.137 (3.48)
MINIMUM
P08C
.300 (7.62)
.390 (9.91)
E D S .010 (.25) M
PI-3933-081716
SMD-8C (G Package)
⊕ D S .004 (.10)
.046 .060 .060 .046
-E-
.080
.086
Pin 1
.137 (3.48)
MINIMUM
Solder Pad Dimensions
.420
.356 (9.05)
.387 (9.83)
.057 (1.45)
.068 (1.73)
(NOTE 5)
.125 (3.18)
.145 (3.68)
.032 (.81)
.037 (.94)
.286
Pin 1
.100 (2.54) (BSC)
-D-
.186
.372 (9.45)
.388 (9.86)
⊕ E S .010 (.25)
.240 (6.10)
.260 (6.60)
Notes:
1. Controlling dimensions are
inches. Millimeter sizes are
shown in parentheses.
2. Dimensions shown do not
include mold flash or other
protrusions. Mold flash or
protrusions shall not exceed
.006 (.15) on any side.
3. Pin locations start with Pin 1,
and continue counter-clockwise to Pin 8 when viewed
from the top. Pin 3 is omitted.
4. Minimum metal to metal
spacing at the package body
for the omitted lead location
is .137 inch (3.48 mm).
5. Lead width measured at
package body.
6. D and E are referenced
datums on the package
body.
.048 (1.22)
.053 (1.35)
.004 (.10)
.009 (.23)
.004 (.10)
.012 (.30)
.036 (0.91)
.044 (1.12)
0 °- 8°
G08C
PI-4015-081716
21
www.power.com
Rev. G 02/19
LinkSwitch-TN2
SO-8C (D Package)
4
B
0.10 (0.004) C A-B 2X
2
DETAIL A
4.90 (0.193) BSC
A
4
8
D
5
2 3.90 (0.154) BSC
GAUGE
PLANE
SEATING
PLANE
6.00 (0.236) BSC
o
0-8
C
1.04 (0.041) REF
2X
0.10 (0.004) C D
1
Pin 1 ID
4
0.40 (0.016)
1.27 (0.050)
0.20 (0.008) C
2X
7X 0.31 - 0.51 (0.012 - 0.020)
0.25 (0.010) M C A-B D
1.27 (0.050) BSC
1.35 (0.053)
1.75 (0.069)
0.25 (0.010)
BSC
1.25 - 1.65
(0.049 - 0.065)
DETAIL A
0.10 (0.004)
0.25 (0.010)
0.10 (0.004) C
H
7X
SEATING PLANE
C
Reference
Solder Pad
Dimensions
+
Notes:
1. JEDEC reference: MS-012.
2.00 (0.079)
+
D07C
0.17 (0.007)
0.25 (0.010)
1.27 (0.050)
4.90 (0.193)
+
+
0.60 (0.024)
2. Package outline exclusive of mold flash and metal burr.
3. Package outline inclusive of plating thickness.
4. Datums A and B to be determined at datum plane H.
5. Controlling dimensions are in millimeters. Inch dimensions
are shown in parenthesis. Angles in degrees.
PI-4526-012315
22
Rev. G 02/19
www.power.com
LinkSwitch-TN2
PDIP-8C (P) and SMD-8C (G) PACKAGE MARKING
B
A
A.
B.
C.
D.
1630
LNK3204P
3Z380J
C
D
Power Integrations Registered Trademark
Assembly Date Code (last two digits of year followed by 2-digit work week)
Product Identification (Part #/Package Type)
Lot Identification Code
PI-8117-093016
SO-8C (D) PACKAGE MARKING
B
A
A.
B.
C.
D.
1630
LNK3202D
4D426E
C
D
Power Integrations Registered Trademark
Assembly Date Code (last two digits of year followed by 2-digit work week)
Product Identification (Part #/Package Type)
Lot Identification Code
PI-8116-092816
23
www.power.com
Rev. G 02/19
LinkSwitch-TN2
MSL Table
Part Number
MSL Rating
LNK3202P
LNK3204P
LNK3294P
LNK3205P
LNK3206P
LNK3296P
N/A
LNK3202G
LNK3204G
LNK3294G
LNK3205G
LNK3206G
LNK3296G
4
LNK3202D
LNK3204D
LNK3205D
LNK3206D
1
ESD and Latch-Up
Test
Conditions
Results
Latch-up at 125 °C
EIA/JESD78
Human Body Model ESD
EIA/JESD22-A114-A
> ±2 kV on all pins except DRAIN (D) pin
> ±1.5 kV on DRAIN (D) pin 725 V parts
> ±2 kV on DRAIN (D) pin 900 V parts
Machine Model ESD
EIA/JESD22-A115-A
> ±200 V on all pins
> ±100 mA or > 1.5 × VMAX on all pins
Part Ordering Information
• LinkSwitch Product Family
• TN2 Series Number
• MOSFET Rating
0
725 V
9
900 V
• Package Identifier
G
Plastic Surface Mount SMD-8C
P
Plastic PDIP-8C
D
Plastic SO-8C (725 V Family only)
• Tape & Reel and Other Options
LNK 3204 G - TL
TL
Tape and Reel, 1 k pcs minimum for G Package. 2.5 k pcs for D Package.
Not available for P Package.
24
Rev. G 02/19
www.power.com
LinkSwitch-TN2
Notes
25
www.power.com
Rev. G 02/19
Revision Notes
Date
A
Code B of 725 V parts.
04/16
B
Code S of 725 V parts.
07/16
C
Code A of 725 V parts.
D
Added IC images on page 1.
10/14/16
10/16
E
Updated Note D, Figure 16, VFB parameter.
11/8/16
F
Updated Figures 12 and 13 Captions. Corrected DRAIN Pin Peak Current to match Figure 15 and Corrected Note 2 in
Absolute Maximum Ratings Section.
01/06/17
G
Code A release of LNK3294 and LNK3296 parts.
02/19
For the latest updates, visit our website: www.power.com
Power Integrations reserves the right to make changes to its products at any time to improve reliability or manufacturability. Power Integrations
does not assume any liability arising from the use of any device or circuit described herein. POWER INTEGRATIONS MAKES NO WARRANTY
HEREIN AND SPECIFICALLY DISCLAIMS ALL WARRANTIES INCLUDING, WITHOUT LIMITATION, THE IMPLIED WARRANTIES OF MERCHANTABILITY,
FITNESS FOR A PARTICULAR PURPOSE, AND NON-INFRINGEMENT OF THIRD PARTY RIGHTS.
Patent Information
The products and applications illustrated herein (including transformer construction and circuits external to the products) may be covered by one
or more U.S. and foreign patents, or potentially by pending U.S. and foreign patent applications assigned to Power Integrations. A complete list of
Power Integrations patents may be found at www.power.com. Power Integrations grants its customers a license under certain patent rights as set
forth at www.power.com/ip.htm.
Life Support Policy
POWER INTEGRATIONS PRODUCTS ARE NOT AUTHORIZED FOR USE AS CRITICAL COMPONENTS IN LIFE SUPPORT DEVICES OR SYSTEMS
WITHOUT THE EXPRESS WRITTEN APPROVAL OF THE PRESIDENT OF POWER INTEGRATIONS. As used herein:
1. A Life support device or system is one which, (i) is intended for surgical implant into the body, or (ii) supports or sustains life, and (iii) whose
failure to perform, when properly used in accordance with instructions for use, can be reasonably expected to result in significant injury or
death to the user.
2. A critical component is any component of a life support device or system whose failure to perform can be reasonably expected to cause the
failure of the life support device or system, or to affect its safety or effectiveness.
Power Integrations, the Power Integrations logo, CAPZero, ChiPhy, CHY, DPA-Switch, EcoSmart, E-Shield, eSIP, eSOP, HiperPLC, HiperPFS,
HiperTFS, InnoSwitch, Innovation in Power Conversion, InSOP, LinkSwitch, LinkZero, LYTSwitch, SENZero, TinySwitch, TOPSwitch, PI, PI Expert,
SCALE, SCALE-1, SCALE-2, SCALE-3 and SCALE-iDriver, are trademarks of Power Integrations, Inc. Other trademarks are property of their
respective companies. ©2019, Power Integrations, Inc.
Power Integrations Worldwide Sales Support Locations
World Headquarters
5245 Hellyer Avenue
San Jose, CA 95138, USA
Main: +1-408-414-9200
Customer Service:
Worldwide: +1-65-635-64480
Americas: +1-408-414-9621
e-mail: usasales@power.com
China (Shanghai)
Rm 2410, Charity Plaza, No. 88
North Caoxi Road
Shanghai, PRC 200030
Phone: +86-21-6354-6323
e-mail: chinasales@power.com
Germany (AC-DC/LED Sales)
Einsteinring 24
85609 Dornach/Aschheim
Germany
Tel: +49-89-5527-39100
e-mail: eurosales@power.com
Germany (Gate Driver Sales)
HellwegForum 1
59469 Ense
Germany
Tel: +49-2938-64-39990
e-mail: igbt-driver.sales@power.com
India
#1, 14th Main Road
China (Shenzhen)
Vasanthanagar
17/F, Hivac Building, No. 2, Keji Nan Bangalore-560052 India
8th Road, Nanshan District,
Phone: +91-80-4113-8020
Shenzhen, China, 518057
e-mail: indiasales@power.com
Phone: +86-755-8672-8689
e-mail: chinasales@power.com
Italy
Via Milanese 20, 3rd. Fl.
20099 Sesto San Giovanni (MI) Italy
Phone: +39-024-550-8701
e-mail: eurosales@power.com
Japan
Yusen Shin-Yokohama 1-chome Bldg.
1-7-9, Shin-Yokohama, Kohoku-ku
Yokohama-shi,
Kanagawa 222-0033 Japan
Phone: +81-45-471-1021
e-mail: japansales@power.com
Korea
RM 602, 6FL
Korea City Air Terminal B/D, 159-6
Samsung-Dong, Kangnam-Gu,
Seoul, 135-728, Korea
Phone: +82-2-2016-6610
e-mail: koreasales@power.com
Singapore
51 Newton Road
#19-01/05 Goldhill Plaza
Singapore, 308900
Phone: +65-6358-2160
e-mail: singaporesales@power.com
Taiwan
5F, No. 318, Nei Hu Rd., Sec. 1
Nei Hu Dist.
Taipei 11493, Taiwan R.O.C.
Phone: +886-2-2659-4570
e-mail: taiwansales@power.com
UK
Building 5, Suite 21
The Westbrook Centre
Milton Road
Cambridge
CB4 1YG
Phone: +44 (0) 7823-557484
e-mail: eurosales@power.com