0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
LNK417EG

LNK417EG

  • 厂商:

    POWERINT(帕沃英蒂格盛)

  • 封装:

    SSIP7

  • 描述:

    IC LED DRIVER OFFL DIM ESIP-7C

  • 数据手册
  • 价格&库存
LNK417EG 数据手册
LNK403-409/413-419 LinkSwitch-PH LED Driver IC Family ™ Single-Stage PFC, Primary-Side Constant Current Control and TRIAC Dimming/Non-Dimming Options Product Highlights Dramatically Simplifies Off-line LED Drivers • Single-stage combination of power factor correction and accurate constant-current (CC) output • Enables very long lifetime designs (no electrolytic capacitors) • Eliminates optocoupler and all secondary current control circuitry • Eliminates control loop compensation circuitry • Simple primary-side PWM dimming interface • Universal input voltage range • LNK403-409 optimized for flicker-free TRIAC dimming EcoSmart™ – Energy Efficient • Single-stage PFC combined with output CC control • Greatly increases efficiency, >90% achievable • Reduces component count • No current sense resistors • Low standby power remote ON/OFF feature (0.9, and TRIAC dimming capability (LNK403-409). The single-stage combined power factor and constant-current controller eliminates a switching stage and the electrolytic bulk capacitor. The advanced primaryside control used by the LinkSwitch-PH device provides accurate constant current control while eliminating the need for an optocoupler and current sensing circuits. LinkSwitch-PH incorporates a 725 V power FET, a continuousmode PWM controller, a high voltage switched current source for self biasing, frequency jittering, protection circuitry including cycle-by-cycle current limit and hysteretic thermal shutdown. www.powerint.com Table 1. Output Power Table. Notes: 1. Continuous power in an open frame with adequate heat sinking at device local ambient of 70 °C. 2. Power level calculated on typical LED string voltage with efficiency >80%. 3. Minimum output power with CBP = 10 mF. 4. Maximum output power with CBP = 100 mF. LNK4x3EG CBP = 10 mF. 5. Package: eSIP-7C, eSIP-7F. eSIP-7C (E Package) Figure 2. Package Options. eSIP-7F (L Package) August 2011 LNK403-409/413-419 BYPASS (BP) BYPASS CAPACITOR SELECT SOFT-START TIMER FAULT PRESENT 5.9 V REGULATOR DRAIN (D) HYSTERETIC THERMAL SHUTDOWN - ILIM MI AUTO-RESTART COUNTER 5.9 V 5.0 V VOLTAGE MONITOR (V) 1V STOP LOGIC JITTER CLOCK OSCILLATOR 3-VT UV/OV LINE SENSE + BYPASS PIN UNDERVOLTAGE Comparator FBOFF DCMAX OCP + FEEDBACK (FB) VBG IV IFB FBOFF DCMAX PFC/CC CONTROL MI FEEDBACK SENSE REFERENCE (R) 6.4 V REFERENCE BLOCK VBG Figure 3. Functional Block Diagram. Pin Functional Description DRAIN (D) Pin: This pin is the power FET drain connection. It also provides internal operating current for both start-up and steady-state operation. SOURCE (S) Pin: This pin is the power FET source connection. It is also the ground reference for the BYPASS, FEEDBACK, REFERENCE and VOLTAGE MONITOR pins. BYPASS (BP) Pin: This is the connection point for an external bypass capacitor for the internally generated 5.9 V supply. This pin also provides output power selection through choice of the BYPASS pin capacitor value. FEEDBACK (FB) Pin: The FEEDBACK pin is used for output voltage feedback. The current into the FEEDBACK pin is directly proportional to the output voltage. The FEEDBACK pin also includes circuitry to protect against open load and overload output conditions. REFERENCE (R) Pin: This pin is connected to an external precision resistor and is used to configure for dimming (LNK403-409) and non-TRIAC dimming (LNK413-419) modes of operation. VOLTAGE MONITOR (V) Pin: This pin interfaces with an external input line peak detector, consisting of a rectifier, filter capacitor and resistors. The applied current is used to control stop logic for line undervoltage (UV), overvoltage (OV), provide feed-forward to control the output current and the remote ON/OFF function. Exposed Pad (Backside) Internally Connected to SOURCE Pin E Package (eSIP-7C) (Top View) 7D 5S 4 BP 3 FB 2V 1R Exposed Pad (backside) Internally Connected to SOURCE Pin (see eSIP-7C Package Drawing) Figure 4. Pin Configuration. 2 Rev. D 08/11 + Gate Driver SenseFet LEB CURRENT LIMIT COMPARATOR - ILIM VSENSE IS PI-5431-102610 SOURCE (S) L Package (eSIP-7F) 135 R FB S 7 Lead Bend Outward 2 4 V BP D from Drawing (Refer to eSIP-7F Package Outline Drawing) PI-5432-082411 www.powerint.com LNK403-409/413-419 Functional Description A LinkSwitch-PH device monolithically integrates a controller and high-voltage power FET into one package. The controller implements both high power factor and a constant current output in a single stage. The LinkSwitch-PH controller consists of an oscillator, feedback (sense and logic) circuit, 5.9 V regulator, hysteretic over-temperature protection, frequency jittering, cycle-by-cycle current limit, auto-restart, inductance correction, power factor and constant current control. FEEDBACK Pin Current Control Characteristics The figure shown below illustrates the operating boundaries of the FEEDBACK pin current. Above IFB(SKIP) switching is disabled and below IFB(AR) the device enters into auto-restart. the line undervoltage and overvoltage thresholds of the VOLTAGE MONITOR pin. For non-dimming or PWM dimming applications with LNK413-419, the external resistor should be a 24.9 kW ±1%, for high-line and universal input voltage designs, and 49.9 kW ±1% for low-line input voltage designs. For phase angle AC dimming with LNK403-409, the external resistor should be a 49.9 kW ±1%. One percent resistors are recommended as the resistor tolerance directly affects the output tolerance. Other resistor values should not be used. BYPASS Pin Capacitor Power Gain Selection LinkSwitch-PH devices have the capability to tailor the internal gain to either full or a reduced output power setting. This allows selection of a larger device to minimize dissipation for both thermal and efficiency reasons. The power gain is selected with the value of the BYPASS pin capacitor. The full power setting is selected with a 100 mF capacitor and the reduced power setting (for higher efficiency) is selected with a 10 mF capacitor. The BYPASS pin capacitor sets both the internal power gain as well as the over-current protection (OCP) threshold. Unlike the larger devices, the LNK4x3 power gain is not programmable. Use a 10 mF capacitor for the LNK4x3. Switching Frequency The switching frequency is 66 kHz. To further reduce the EMI level, the switching frequency is jittered (frequency modulated) by approximately ±1 kHz. Soft-Start The controller includes a soft-start timing feature which inhibits the auto-restart protection feature for the soft-start period (tSOFT ) to distinguish start-up into a fault (short-circuit) from a large output capacitor. At start-up the LinkSwitch-PH clamps the maximum duty cycle to reduce the output power. The total soft-start period is tSOFT. Remote ON/OFF and EcoSmart The VOLTAGE MONITOR pin has a 1 V threshold comparator connected at its input. This voltage threshold is used for remote ON/OFF control. When a signal is received at the VOLTAGE MONITOR pin to disable the output (VOLTAGE MONITOR pin tied to ground through an optocoupler phototransistor) the LinkSwitch-PH will complete its current switching cycle before the internal power FET is forced off. The remote ON/OFF feature can also be used as an eco-mode or power switch to turn off the LinkSwitch-PH and keep it in a very low power consumption state for indefinite long periods. When the LinkSwitch-PH is remotely turned on after entering this mode, it will initiate a normal start-up sequence with soft-start the next time the BYPASS pin reaches 5.9 V. In the worst case, the delay from remote on to start-up can be equal to the full discharge/charge cycle time of the BYPASS pin. This reduced consumption remote off mode can eliminate expensive and unreliable in-line mechanical switches. IFB(SKIP) Skip-Cycle IFB CC Control Region IFB(DCMAXR) Soft-Start and CC Fold-Back Region IFB(AR) DC10 Auto-Restart DCMAX PI-5433-060410 Maximum Duty Cycle Figure 5. FEEDBACK Pin Current Characteristic. The FEEDBACK pin current is also used to clamp the maximum duty cycle to limit the available output power for overload and open-loop conditions. This duty cycle reduction characteristic also promotes a monotonic output current start-up characteristic to prevent over-shoot. REFERENCE Pin The REFERENCE pin is tied to ground (SOURCE) via an external resistor. The value selected sets the internal references, determining the operating mode for dimming (LNK403-409) and non-dimming (LNK413-419) operation and 3 www.powerint.com Rev. D 08/11 LNK403-409/413-419 Over-Current Protection The current limit circuit senses the current in the power FET. When this current exceeds the internal threshold (ILIMIT), the power FET is turned off for the remainder of that cycle. A leading edge blanking circuit inhibits the current limit comparator for a short time (tLEB) after the power FET is turned on. This leading edge blanking time has been set so that current spikes caused by capacitance and rectifier reverse recovery will not cause premature termination of the power FET conduction. Line Under/Overvoltage Protection This device includes both line under- and overvoltage detection to limit the minimum start-up and maximum operating voltage detected through the VOLTAGE MONITOR pin. An external peak detector consisting of a diode and capacitor are required to provide input line peak voltage to the VOLTAGE MONITOR pin through a resistor. At power up, IUV+ keeps the LinkSwitch-PH off until the input line voltage reaches the undervoltage threshold. At power down, IUV- prevents restart attempts after the output goes out of regulation. The same resistor used for UV also sets line overvoltage (OV) shutdown threshold which, once exceeded, forces the LinkSwitch-PH to stop switching (after completion of the current switching cycle). Once the line voltage returns to normal, the device resumes normal operation. A small amount of hysteresis is provided on the OV threshold to prevent noise triggering. When the power FET is off, the rectified DC high voltage surge capability is increased to the voltage rating of the power FET (725 V), due to the absence of the reflected voltage and leakage spikes on the drain. Hysteretic Thermal Shutdown The thermal shutdown circuitry senses the controller die temperature. The threshold is set at 142 °C typical with a 75 °C hysteresis. When the die temperature rises above this threshold (142 °C) the power FET is disabled and remains disabled until the die temperature falls by 75 °C, at which point the power FET is re-enabled. Safe Operating Area (SOA) Protection The device also features a safe operating area (SOA) protection mode which disables FET switching for 40 cycles in the event the peak switch current reaches the ILIMIT threshold and the switch on-time is less than tON(SOA). This protection mode protects the device under short-circuited LED conditions and at start-up during the soft-start period when auto-restart protection is inhibited. The SOA protection mode remains active in normal operation. D V CONTROL BP S R FB PI-5435-052510 Figure 6. Remote ON/OFF VOLTAGE MONITOR pin Control 5.9 V Regulator/Shunt Voltage Clamp The internal 5.9 V regulator charges the bypass capacitor connected to the BYPASS pin to 5.9 V by drawing a current from the voltage on the DRAIN pin whenever the power FET is off. The BYPASS pin is the internal supply voltage node. When the power FET is on, the device operates from the energy stored in the bypass capacitor. Extremely low power consumption of the internal circuitry allows LinkSwitch-PH to operate continuously from current it takes from the DRAIN pin. A bypass capacitor value of 10 or 100 mF is sufficient for both high frequency decoupling and energy storage. In addition, there is a 6.4 V shunt regulator clamping the BYPASS pin at 6.4 V when current is provided to the BYPASS pin through an external resistor. This facilitates powering of LinkSwitch-PH externally through a bias winding to increase operating efficiency. It is recommended that the BYPASS pin is supplied current from the bias winding for normal operation. Auto-Restart In the event of an open-loop fault (open FEEDBACK pin resistor or broken path to feedback winding), output short-circuits or an overload condition the controller enters into the auto-restart mode. The controller annunciates both short-circuit and open-loop conditions once the FEEDBACK pin current falls below the IFB(AR) threshold after the soft-start period. To minimize the power dissipation under this fault condition the shutdown/auto-restart circuit turns the power supply on (same as the soft-start period) and off at an auto-restart duty cycle of typically DCAR for as long as the fault condition persists. If the fault is removed during the auto-restart off-time, the power supply will remain in auto-restart until the full off-time count is completed. Special consideration must be made to appropriately size the output capacitor to ensure that after the soft-start period (tSOFT ) the FEEDBACK pin current is above the IFB(AR) threshold to ensure successful power-supply start-up. After the soft-start time period, auto-restart is activated only when the FEEDBACK pin current falls below IFB(AR). 4 Rev. D 08/11 www.powerint.com LNK403-409/413-419 Application Example 14 W TRIAC Dimmable High Power Factor LED Driver Design Example The circuit schematic in Figure 7 shows a TRIAC dimmable high power-factor LED driver based on LNK406EG from the LinkSwitch-PH family of devices. It was optimized to drive an LED string at a voltage of 28 V with a constant current of 0.5 A (±5%) ideal for PAR lamp retro-fit applications. The design operates over a universal input voltage range of 90 VAC to 265 VAC but provides the specified output current tolerance over a line voltage range of 90 VAC to 132 VAC (this is configurable for high-line only applications by simple component value changes). The key goals of this design were compatibility with standard leading edge TRIAC AC dimmers, very wide dimming range (1000:1, 500 mA:0.5 mA), high efficiency (>85%) and high power factor (>0.9). The design is fully protected from faults such as no-load, overload and output short-circuit conditions and over temperature. Circuit Description The LinkSwitch-PH device (U1) integrates the power FET, controller and start-up functions into a single package reducing the component count versus typical implementations. Configured as part of an isolated continuous conduction mode flyback converter, U1 provides high power factor via its internal control algorithm together with the small input capacitance of the design. Continuous conduction mode operation results in reduced primary peak and RMS current. This both reduces EMI noise, allowing simpler, smaller EMI filtering components and improves efficiency. Output current regulation is maintained without the need for secondary side sensing which eliminates current sense resistors and improves efficiency. Input Stage Fuse F1 provides protection from component failures while RV1 provides a clamp during differential line surges, keeping the peak drain voltage of U1 below the 725 V rating of the internal power FET. Bridge rectifier BR1 rectifies the AC line voltage. EMI filtering is provided by L1-L3, C1, R16 and R17 together with the safety rated Y class capacitor (C7) that bridges the safety isolation barrier between primary and secondary. Resistor R16 and R17 act to damp any resonances formed between L1, L2, C1 and the AC line impedance. A small bulk capacitor (C2) is required to provide a low impedance source for the primary switching current. The maximum value of C1 and C2 is limited in order to maintain a power factor of greater than 0.9. LinkSwitch-PH Primary To provide peak line voltage information to U1 the incoming rectified AC peak charges C3 via D2. This is then fed into the VOLTAGE MONITOR pin of U1 as a current via R2 and R3. This sensed current is also used by the device to set the line input overvoltage and undervoltage protection thresholds. Resistor R1 provides a discharge path for C3 with a time constant much longer than that of the rectified AC to prevent generation of line frequency ripple. The VOLTAGE MONITOR pin current and the FEEDBACK pin current are used internally to control the average output LED current. For TRIAC phase-dimming applications a 49.9 kW resistor (R4) is used on the REFERENCE pin and 4 MW (R2+R3) on the VOLTAGE MONITOR pin to provide a linear relationship between input voltage and the output current and maximizing the dimming range. Resistor R4 also sets the internal line input undervoltage and overvoltage protection thresholds. 11 FL1 C8 C10 330 µF 330 µF R15 50 V 50 V 20 kΩ D8 MBRS4201T3G 28 V, 500 mA L3 1000 µH R9 750 kΩ 1% R18 510 Ω 1W R16 1 kΩ L F1 3.15 A L1 1000 µH 90 - 265 VAC RV1 275 VAC C1 47 nF 275 VAC C11 220 nF 630 V C2 100 nF 630 V BR1 2KBP06M 600 V R10 750 kΩ 1% R2 2 MΩ 1% R3 2 MΩ 1% C3 1 µF 400 V D V CONTROL R1 240 kΩ 1/2 W D2 DL4007 VR1 P6KE200A D3 UF4007 1 FL2 3 RTN R8 D6 150 Ω DL4936 R7 10 kΩ C5 22 µF 50 V 2 T1 RM8 D4 UF4002 D5 1N4148 R5 3 kΩ BP L2 1000 µH N R17 1 kΩ D1 DL4002 VR2 ZMM5245B-7 15 V R12 15 Ω 1% LinkSwitch-PH U1 LNK406EG S R6 162 kΩ 1% VR3 ZMM5259B-7 39 V D7 BAV21WS-7-F R FB R11 2.4 MΩ Q1 FMMT558 C6 15 nF 50 V Q2 IRFR310 R13 130 Ω 1/2 W Q3 MMBT3904 C13 100 nF 50 V R4 49.9 kΩ C4 1% 10 µF 16 V R19 1 kΩ R20 10 kΩ C12 1 µF 50 V C7 2.2 nF 250 VAC PI-5997-061510 Figure 7. Schematic of an Isolated, TRIAC Dimmable, High Power Factor, Universal Input, 14 W LED Driver. 5 www.powerint.com Rev. D 08/11 LNK403-409/413-419 Diode D3 and VR1 clamp the drain voltage to a safe level due to the effects of leakage inductance. Diode D4 is necessary to prevent reverse current from flowing through U1 for the period of the rectified AC input voltage that the voltage across C2 falls to below the reflected output voltage (VOR). Diode D6, C5, R7 and R8 create the primary bias supply from an auxiliary winding on the transformer. Capacitor C4 provides local decoupling for the BYPASS pin of U1 which is the supply pin for the internal controller. During start-up C4 is charged to ~6 V from an internal high-voltage current source tied to the device DRAIN pin. This allows the part to start switching at which point the operating supply current is provided from the bias supply via R5. Capacitor C4 also selects the output power mode (10 mF for reduced power was selected to reduce dissipation in U1 and increase efficiency). Feedback The bias winding voltage is proportional to the output voltage (set by the turns ratio between the bias and secondary windings). This allows the output voltage to be monitored without secondary side feedback components. Resistor R6 converts the bias voltage into a current which is fed into the FEEDBACK pin of U1. The internal engine within U1 combines the FEEDBACK pin current, VOLTAGE MONITOR pin current and drain current information to provide a constant output current over a 1.5:1 output voltage variation (LED string voltage variation of ±25%) at a fixed line input voltage. To limit the output voltage at no-load an output overvoltage protection circuit is set by D7, C12, R20, VR3, C13, Q3 and R19. Should the output load be disconnected then the bias voltage will increase until VR3 conducts, turning on Q3 and reducing the current into the FEEDBACK pin. When this current drops below 20 mA the part enters auto-restart and switching is disabled for 1500 ms allowing time for the output and bias voltages to fall. Output Rectification The transformer secondary winding is rectified by D8 and filtered by C8 and C10. A Schottky barrier diode was selected for efficiency and the combined value of C8 and C10 were selected to give peak-to-peak and LED ripple current equal to 40% of the mean value. For designs where lower ripple is desirable the output capacitance value can be increased. A small pre-load is provided by R15 which limits the output voltage under no-load conditions. TRIAC Phase Dimming Control Compatibility The requirement to provide output dimming with low cost, TRIAC-based, leading edge phase dimmers introduces a number of trade-offs in the design. Due to the much lower power consumed by LED based lighting the current drawn by the overall lamp is below the holding current of the TRIAC within the dimmer. This can cause undesirable behaviors such as limited dimming range and/or flickering as the TRIAC fires inconsistently. The relatively large impedance the LED lamp presents to the line allows significant ringing to occur due to the inrush current charging the input capacitance when the TRIAC turns on. This too can cause similar undesirable behavior as the ringing may cause the TRIAC current to fall to zero and turn off. To overcome these issues two circuits, the Active Damper and Passive Bleeder, are incorporated. The drawback of these circuits is increased dissipation and therefore reduced efficiency of the supply. For non-dimming applications these components can simply be omitted. The Active Damper consists of components R9, R10, R11, R12, D1, Q1, C6, VR2, Q2 in conjunction with R13. This circuit limits the inrush current that flows to charge C2 when the TRIAC turns on by placing R13 in series for the first 1 ms of the TRIAC conduction. After approximately 1 ms, Q2 turns on and shorts R13. This keeps the power dissipation on R13 low and allows a larger value during current limiting. Resistor R9, R10, R11 and C6 provide the 1 ms delay after the TRIAC conducts. Transistor Q1 discharges C6 when the TRIAC is not conducting and VR2 clamps the gate voltage of Q2 to 15 V. The Passive Bleeder circuit is comprised of C11 and R18. This helps to keep the input current above the TRIAC holding current while the input current corresponding to the effective driver resistance increases during each AC half-cycle. 6 Rev. D 08/11 www.powerint.com LNK403-409/413-419 7 W High Power Factor Non-Dimmable LED Driver Design Example with Enhanced Line Regulation The circuit schematic in Figure 7 shows a high power-factor LED driver based on a LNK413EG from the LinkSwitch-PH family of devices. It was optimized to drive an LED string at a voltage of 21 V with a constant current of 0.33 A, ideal for PAR20/PAR30 lamp retro-fit applications. The design operates over the universal input voltage range of 90 VAC to 265 VAC and is a non-dimming application. A non-dimming application has tighter output current variation with changes in the line voltage than a dimming application. It’s key to note that, although not specified for dimming, no circuit damage will result if the end user does operate the design with a phase controlled dimmer. Circuit Description Input Stage Fuse F1 provides protection from component failures while RV1 provides a clamp during differential line surges, keeping the peak drain voltage of U1 below the 725 V rating of the internal power FET. Bridge rectifier BR1 rectifies the AC line voltage. EMI filtering is provided by L1-L3, C2 together with the safety rated Y class capacitor (C7) that bridges the safety isolation barrier between primary and secondary. Resistor R2 and R3 act to damp any resonances formed between L1, L2, C2 and the AC line impedance. A small bulk capacitor (C3) is required to provide a low impedance source for the primary switching current. The maximum value of C2 and C3 is limited in order to maintain a power factor of greater than 0.9. LinkSwitch-PH Primary To provide peak line voltage information to U1 the incoming rectified AC peak charges C8 via D6. This is then fed into the VOLTAGE MONITOR pin of U1 as a current via R4, R7 and R8. The VOLTAGE MONITOR pin current and the FEEDBACK pin current are used internally to control the average output LED current. The combined value of R4, R7 and R8 (3.909 MW) and R11, R12 (1.402 MW) connected to the VOLTAGE MONITOR pin provides excellent line regulation over the entire 90 VAC to 265 VAC input range. The VOLTAGE MONITOR pin current is also used by the device to set the line input overvoltage and undervoltage protection thresholds. Diode D1 and VR1 clamp the drain voltage to a safe level due to the effects of leakage inductance. A Zener clamp was selected for lowest component count and highest efficiency. Diode D5 is necessary to prevent reverse current from flowing through U1 during the period when the AC input voltage is lower than the reflected output voltage (VOR). A space efficient RM6 core was selected for this design. The RM core geometry helps minimizes audible noise but requires the use of flying leads to meet safety spacing requirements. Diode D3, C6, R5, R9 and R18 create the primary bias supply from an auxiliary winding on the transformer. Resistor R5 provides filtering of leakage inductance generated voltage spikes to improve tracking of the bias and output voltages. It also forms a pole with C6 at ~100 Hz. Resistors R9 and R18 act as a small load to ensure that the bias voltage collapses during output short-circuit when U1 enters auto-restart operation to protect the supply. Output overvoltage and load disconnection protection is provided by D8, C14, R24, VR3, C15, R23 and Q2. Should the output LED load become disconnected the output voltage will rise causing an associated rise in the bias winding voltage across C14. Once this exceeds the voltage rating of VR3, Q2 turns on pulling down the FEEDBACK pin of U1 and initiating auto-restart operation. Once in auto-restart the low duty cycle of operation (~3%) together with the small pre-load on the output prevents the output voltage rising to a high level. Once the output load is reconnected normal operation resumes. Capacitor C12 provides local decoupling for the BYPASS pin of U1 which is the supply pin for the internal controller. During C5 C4 R6 150 µF 150 µF 35 V 35 V 20 kΩ D2 MBRS4201T3G D6 DL4007 VR1 P6KE200A D1 UF4007 2 T1 RM6 1 FL3 6 FL1 FL2 21 V, 330 mA L3 1000 µH RTN R5 D3 75 Ω DL4936 R9 R18 10 kΩ 10 kΩ C6 22 µF 50 V R2 1 kΩ L F1 3.15 A L1 1000 µH 90 - 265 VAC RV1 275 VAC C2 22 nF 275 VAC BR1 DF06S-E3/45 600 V R4 2 MΩ 1% R7 1 MΩ 1% C8 1 µF 400 V R8 909 kΩ 1% C3 100 nF 400 V D5 ES1D D4 1N4148 D V CONTROL L2 1000 µH R10 3 kΩ BP N R3 1 kΩ R11 1.0 MΩ 1% LinkSwitch-PH U1 LNK413EG S R15 150 kΩ D8 BAV21WS-7-F VR3 ZMM5259B-7 39 V R24 10 kΩ C14 1 µF 50 V R FB R12 402 kΩ 1% Q2 MMBT3904 C15 100 nF 50 V R19 24.9 kΩ 1% C12 10 µF 10 V R23 1 kΩ C7 2.2 nF 250 VAC PI-5991-101210 Figure 8. Schematic of an Isolated, Non-Dimmable, High Power Factor, Universal Input, 7 W LED Driver. 7 www.powerint.com Rev. D 08/11 LNK403-409/413-419 start-up C4 is charged to ~6 V from an internal high-voltage current source tied to the device DRAIN pin. Once the bias voltage has risen into regulation the operating supply current is provided via R10. Diode D4 prevents U1 from charging C6 during start-up which would increase the start-up delay time. Feedback The bias winding voltage is proportional to the output voltage (set by the turns ratio between the bias and secondary windings). This allows the output voltage to be monitored without secondary side feedback components. Resistor R15 converts the bias voltage into a current which is fed into the FEEDBACK pin of U1. The internal engine within U1 combines the FEEDBACK pin current, VOLTAGE MONITOR pin current and drain current information to provide a constant output current over a 2:1 output voltage range. Output Rectification The transformer secondary winding is rectified by D2 and filtered by C4 and C5. A Schottky barrier diode was selected for efficiency and the combined value of C4 and C5 were selected to give an acceptable LED ripple current. For designs where lower ripple is desirable the output capacitance value can be increased. A small pre-load is provided by R6 which limits the output voltage under no-load conditions. 100 mF BYPASS pin capacitor for all but the LNK4x3 which has only one power setting. In all cases in order to obtain the best output current tolerance maintain the device temperature below 100 °C Maximum Input Capacitance To achieve high power factor, the capacitance used in both the EMI filter and for decoupling the rectified AC (bulk capacitor) must be limited in value. The maximum value is a function of the output power of the design and reduces as the output power reduces. For the majority of designs limit the total capacitance to less than 200 nF with a bulk capacitor value of 100 nF. Film capacitors are recommended compared to ceramic types as they minimize audible noise with operating with leading edge phase dimmers. Start with a value of 10 nF for the capacitance in the EMI filter and increase in value until there is sufficient EMI margin. REFERENCE Pin Resistance Value Selection The LinkSwitch-PH family contains phase dimming devices, LNK403-409, and non-dimming devices, LNK413-419. The non-dimmable devices use a 24.9 kW ±1% REFERENCE pin resistor in high-line and universal input voltage designs and 49.9 kW ±1% in low-line input voltage designs, for best output current tolerance (over AC input voltage changes). The dimmable devices use 49.9 kW ±1% to achieve the widest dimming range. VOLTAGE MONITOR Pin Resistance Network Selection For widest AC phase angle dimming range with LNK403-409, use a 4 MW resistor connected to the line voltage peak detector circuit. Make sure that the resistor’s voltage rating is sufficient for the peak line voltage. If necessary use multiple series connected resistors. For best line regulation, use a series combination of resistors that equals 3.909 MW connected to the line voltage peak detector. In addition, connect a 1 MW in series with a 402 kW resistor (1.402 MW total) from the VOLTAGE MONITOR pin to SOURCE pin. Use 1% tolerance resistors for good accuracy. Line regulation can be further improved by using the PIXls spreadsheet’s fine tuning section. See the LinkSwitch-PH Application Note for more information. Primary Clamp and Output Reflected Voltage VOR A primary clamp is necessary to limit the peak drain to source voltage. A Zener clamp requires the fewest components and board space and gives the highest efficiency. RCD clamps are also acceptable however the peak drain voltage should be carefully verified during start-up and output short-circuit as the clamping voltage varies with significantly with the peak drain current. For the highest efficiency, the clamping voltage should be selected to be at least 1.5 times the output reflected voltage, VOR, as this keeps the leakage spike conduction time short. When using a Zener clamp in a universal input or high-line only application, a VOR of less than 135 V is recommended to allow for the absolute tolerances and temperature variations of the Zener. This will ensure efficient operation of the clamp circuit and will also keep the maximum drain voltage below the rated breakdown voltage of the FET. An RCD (or RCDZ) clamp Key Application Considerations Power Table The data sheet power table (Table 1) represents the minimum and maximum practical continuous output power based on the following conditions: 1. Efficiency of 80% 2. Device local ambient of 70 °C 3. Sufficient heat sinking to keep the device temperature below 100 °C 4. For minimum output power column • Reflected output voltage (VOR) of 120 V • FEEDBACK pin current of 135 m A • BYPASS pin capacitor value of 10 mF 5. For maximum output power column • Reflected output voltage (VOR) of 65 V • FEEDBACK pin current of 165 m A • BYPASS pin capacitor value of 100 mF (LNK4x3EG = 10 mF) Note that input line voltages above 85 VAC do not change the power delivery capability of LinkSwitch-PH devices. Device Selection Select the device size by comparing the required output power to the values in Table 1. For thermally challenging designs, e.g. incandescent lamp replacement, where either the ambient temperature local to the LinkSwitch-PH device is high and/or there is minimal space for heat sinking use the minimum output power column. This is selected by using a 10 mF BYPASS pin capacitor and results in a lower device current limit and therefore lower conduction losses. For open frame design or designs where space is available for heat sinking then refer to the maximum output power column. This is selected by using a 8 Rev. D 08/11 www.powerint.com LNK403-409/413-419 provides tighter clamp voltage tolerance than a Zener clamp. The RCD clamp is more cost effective than the Zener clamp but requires more careful design to ensure that the maximum drain voltage does not exceed the power FET breakdown voltage. These VOR limits are based on the BVDSS rating of the internal FET, a VOR of 60 V to 100 V is typical for most designs, giving the best PFC and regulation performance. Series Drain Diode An ultra-fast or Schottky diode in series with the drain is necessary to prevent reverse current flowing through the device. The voltage rating must exceed the output reflected voltage, VOR. The current rating should exceed two times the average primary current and have a peak rating equal to the maximum drain current of the selected LinkSwitch-PH device. Line Voltage Peak Detector Circuit LinkSwitch-PH devices use the peak line voltage to regulate the power delivery to the output. A capacitor value of 1 mF to 4.7 mF is recommended to minimize line ripple and give the highest power factor (>0.9), smaller values are acceptable but result in lower PF and higher line current distortion. Operation with Phase Controlled Dimmers Dimmer switches control incandescent lamp brightness by not conducting (blanking) for a portion of the AC voltage sine wave. This reduces the RMS voltage applied to the lamp thus reducing the brightness. This is called natural dimming and the LinkSwitch-PH LNK403-409 devices when configured for dimming utilize natural dimming by reducing the LED current as the RMS line voltage decreases. By this nature, line regulation performance is purposely decreased to increase the dimming range and more closely mimic the operation of an incandescent lamp. Using a 49.9 kW REFERENCE pin resistance selects natural dimming mode operation. Leading Edge Phase Controlled Dimmers The requirement to provide flicker-free output dimming with low cost, TRIAC-based, leading edge phase dimmers introduces a number of trade-offs in the design. Due to the much lower power consumed by LED based lighting the current drawn by the overall lamp is below the holding current of the TRIAC within the dimmer. This causes undesirable behaviors such as limited dimming range and/or flickering. The relatively large impedance the LED lamp presents to the line allows significant ringing to occur due to the inrush current charging the input capacitance when the TRIAC turns on. This too can cause similar undesirable behavior as the ringing may cause the TRIAC current to fall to zero and turn off. To overcome these issues two circuits, the Active Damper and Passive Bleeder, are incorporated. The drawback of these circuits is increased dissipation and therefore reduced efficiency of the supply so for non-dimming applications these components can simply be omitted. Figure 9(a) shows the line voltage and current at the input of a leading edge TRIAC dimmer with Figure 9(b) showing the resultant rectified bus voltage. In this example, the TRIAC conducts at 90 degrees. 350 250 150 50 -50 -150 -250 -350 0.5 50 100 150 200 250 300 350 400 PI-5983-060810 Voltage Current 0.25 0.15 0.05 -0.05 -0.15 -0.25 -0.35 Conduction Angle (°) 350 PI-5984-060810 0.35 0.3 0.25 0.2 0.15 0.1 0.05 0 Rectified Input Voltage (V) 300 250 200 150 100 50 0 0 50 100 150 200 250 300 350 400 Conduction Angle (°) Figure 9. (a) Ideal Input Voltage and Current Waveforms for a Leading Edge TRIAC Dimmer at 90° Conduction Angle. (b) Resultant Waveforms Following Rectification of TRIAC Dimmer Output. Figure 10 shows undesired rectified bus voltage and current with the TRIAC turning off prematurely and restarting. If the TRIAC is turning off before the end of the half-cycle erratically or alternate half AC cycles have different conduction angles then flicker will be observed in the LED light due to variations in the output current. This can be solved by including a bleeder and damper circuit. Dimmers will behave differently based on manufacturer and power rating, for example a 300 W dimmer requires less dampening and requires less power loss in the bleeder than a 600 W or 1000 W dimmer due to different drive circuits and TRIAC holding current specifications. Line voltage also has a significant impact as at high-line for a given output power the input current and therefore TRIAC current is lower but the peak inrush current when the input capacitance charges is higher creating more ringing. Finally multiple lamps in parallel driven from the same dimmer can introduce more ringing due to the increased capacitance of parallel units. Therefore when testing dimmer operation verify on a number of models, different line voltages and with both a single driver and multiple drivers in parallel. 9 www.powerint.com Rev. D 08/11 Rectified Input Current (A) Voltage Current Line Current (Through Dimmer) (A) Line Voltage (at Dimmer Input) (V) 0.35 LNK403-409/413-419 350 PI-5985-102810 0.35 350 PI-5986-060810 0.35 0.25 0.15 0.05 Rectified Input Voltage (V) 300 250 200 150 100 50 0 0.3 0.25 0.2 0.15 0.1 0.05 0 250 150 50 -50 0 -150 -250 -350 50 100 150 200 250 300 350 -0.05 -0.15 -0.25 -0.35 0 50 100 150 200 250 300 350 400 Conduction Angle (°) Figure 10. E xample of Phase Angle Dimmer Showing Erratic Firing. Conduction Angle (°) Figure 11. Ideal Dimmer Output Voltage and Current Waveforms for a Trailing Edge Dimmer at 90° Conduction Angle. Start by adding a bleeder circuit. Add a 0.44 mF capacitor and 510 W 1 W resistor (components in series) across the rectified bus (C11 and R18 in Figure 7). If this results in satisfactory operation reduce the capacitor value to the smallest that results in acceptable performance to reduce losses and increase efficiency. If the bleeder circuit does not maintain conduction in the TRIAC, then add an active damper as shown in Figure 7. This consists of components R9, R10, R11, R12, D1, Q1, C6, VR2, Q2 in conjunction with R13. This circuit limits the inrush current that flows to charge C2 when the TRIAC turns on by placing R13 in series for the first 1 ms of the TRIAC conduction. After approximately 1 ms, Q2 turns on and shorts R13. This keeps the power dissipation on R13 low and allows a larger value to be used during current limiting. Increasing the delay before Q2 turns on by increasing the values of resistors R9 and R10 will improve dimmer compatibility but cause more power to be dissipated across R13. Monitor the AC line current and voltage at the input of the power supply as you make the adjustments. Increase the delay until the TRIAC operates properly but keep the delay as short as possible for efficiency. As a general rule the greater the power dissipated in the bleeder and damper circuits, the more dimmer types will work with the driver. Trailing Edge Phase Controlled Dimmers Figure 11 shows the line voltage and current at the input of the power supply with a trailing edge dimmer. In this example, the dimmer conducts at 90 degrees. Many of these dimmers use back-to-back connected power FETs rather than a TRIAC to control the load. This eliminates the holding current issue of TRIACs and since the conduction begins at the zero crossing, high current surges and line ringing are minimized. Typically these types of dimmers do not require damping and bleeder circuits. Audible Noise Considerations for Use With Leading Edge Dimmers Noise created when dimming is typically created by the input capacitors, EMI filter inductors and the transformer. The input capacitors and inductors experience high di/dt and dv/dt every AC half-cycle as the TRIAC fires and an inrush current flows to charge the input capacitance. Noise can be minimized by selecting film vs ceramic capacitors, minimizing the capacitor value and selecting inductors that are physically short and wide. The transformer may also create noise which can be minimized by avoiding cores with long narrow legs (high mechanical resonant frequency). For example, RM cores produce less audible noise than EE cores for the same flux density. Reducing the core flux density will also reduce the noise. Reducing the maximum flux density (BM) to 1500 Gauss usually eliminates any audible noise but must be balanced with the increased core size needed for a given output power. Thermal and Lifetime Considerations Lighting applications present thermal challenges to the driver. In many cases the LED load dissipation determines the working ambient temperature experienced by the drive so thermal evaluation should be performed with the driver inside the final enclosure. Temperature has a direct impact on driver and LED lifetime. For every 10 °C rise in temperature, component life is reduced by a factor of 2. Therefore it is important to properly heat sink and verify the operating temperatures of all devices. 10 Rev. D 08/11 www.powerint.com Dimmer Output Current (A) Dimmer Output Voltage (V) Rectified Input Current (A) Voltage Current Voltage Current LNK403-409/413-419 Layout Considerations Primary Side Connections Use a single point (Kelvin) connection at the negative terminal of the input filter capacitor for the SOURCE pin and bias returns. This improves surge capabilities by returning surge currents from the bias winding directly to the input filter capacitor. The BYPASS pin capacitor should be located as close to the BYPASS pin and connected as close to the SOURCE pin as possible. The SOURCE pin trace should not be shared with the main power FET switching currents. All FEEDBACK pin components that connect to the SOURCE pin should follow the same rules as the BYPASS pin capacitor. It is critical that the main power FET switching currents return to the bulk capacitor with the shortest path as possible. Long high current paths create excessive conducted and radiated noise. Secondary Side Connections The output rectifier and output filter capacitor should be as close as possible. The transformer’s output return pin should have a short trace to the return side of the output filter capacitor. Bulk Capacitor Clamp FL1 LNK403EG 6 Input EMI Filter R2 R14 VR1 L3 C9 C3 C8 D1 U1 2 1 Transformer 5 3 4 F1 L N RV1 L1 L2 C2 C15 R23 T1 R15 FL3 C7 C12 FL2 R3 R16 Copper Area for Heat Sinking R24 C14 VR3 C5 C4 C6 V BYPASS Pin Capacitor V Output Filter Capacitors R10 D8 PI-5987-060110 Figure 12. RD-193 7 W Layout Example, Top Layer. 11 www.powerint.com Rev. D 08/11 LNK403-409/413-419 R13 R12 D7 D6 D1 D5 D1 R17 R5 R19 S R20 S BR1 VR2 R9 F1 B3 R18 R6 D2 C13 R4 R7 Output Rectifier D3 Bridge Rectifier Active Damper MOSFET PI-5988-060110 Figure 13. RD-193 7 W Layout Example, Bottom Layer. Quick Design Checklist Maximum Drain Voltage Verify that the peak VDS does not exceed 725 V under all operating conditions including start up and fault conditions. Maximum Drain Current Measure the peak drain current under all operation conditions including start up and fault conditions. Look for signs of transformer saturation (usually occurs at highest operating ambient temperatures). Verify that the peak current is less that stated for the Absolute Maximum Rating in the data sheet. Thermal Check At maximum output power, both minimum and maximum line voltage and ambient temperature; verify that temperature specifications are not exceeded for the LinkSwitch-PH, transformer, output diodes, output capacitors and drain clamp components. 12 Rev. D 08/11 www.powerint.com LNK403-409/413-419 Absolute Maximum Ratings(1,4) DRAIN Pin Peak Current(5): LNK403, LNK413 ................... 1.37 A LNK404, LNK414 ...................2.08 A LNK405, LNK415 ................... 2.72 A LNK406, LNK416 .................. 4.08 A LNK407, LNK417 .................. 5.44 A LNK408, LNK418 .................. 6.88 A LNK409, LNK419 ................... 7.73 A DRAIN Pin Voltage ……………………… ................ -0.3 to 725 V BYPASS Pin Voltage ……………………… ................. -0.3 to 9 V BYPASS Pin Current ……………………… ..................... 100 mA VOLTAGE MONITOR Pin Voltage …....................………-0.3 to 9 V FEEDBACK Pin Voltage …….. .................................. -0.3 to 9 V REFERENCE Pin Voltage .......................................... -0.3 to 9 V Thermal Resistance Thermal Resistance: eSIP Package: (qJA) .................................................... 105 °C/W(1) (qJC) ............................................... ...........2 °C/W(2) Notes: 1. Free Standing with no heat sink. 2. Measured at back surface tab. Lead Temperature(3) ....................................................... ......... 260 °C Storage Temperature …………………. .................. -65 to 150 °C Operating Junction Temperature(2).........................-40 to 150 °C Notes: 1. All voltages referenced to SOURCE, TA = 25 °C. 2. Normally limited by internal circuitry. 3. 1/16 in. from case for 5 seconds. 4. Absolute Maximum Ratings specified may be applied, one at a time without causing permanent damage to the product. Exposure to Absolute Maximum Ratings for extended periods of time may affect product reliability. 5. Peak DRAIN current is allowed while the DRAIN voltage is simultaneously less than 400 V. See also Figure 17. Parameter Control Functions Switching Frequency Frequency Jitter Modulation Rate Symbol Conditions SOURCE = 0 V; TJ = -20 °C to 125 °C (Unless Otherwise Specified) Average Peak-Peak Jitter Min Typ Max Units fOSC fM TJ = 25 °C 62 66 9 1 70 kHz kHz TJ = 25 °C See Note B VBP = 0 V, TJ = 25 °C LNK403, LNK413 LNK404, LNK414 LNK405-409, LNK415-419 LNK403, LNK413 LNK404, LNK414 LNK405-409, LNK415-419 See Note A -5.0 -9.6 -15 -1.6 -4.2 -8.2 ICH1 BYPASS Pin Charge Current ICH2 Charging Current Temperature Drift BYPASS Pin Voltage BYPASS Pin Voltage Hysteresis BYPASS Pin Shunt Voltage Soft-Start Time VBP VBP(H) VBP(SHUNT) tSOFT -4.2 -8.0 -11.9 -1.2 -3.5 -6.4 0.5 -3.4 -6.4 -8.8 -0.6 -2.8 -4.6 %/°C 6.1 V V 6.7 V ms mA VBP = 5 V, TJ = 25 °C 0 °C < TJ < 100 °C 0 °C < TJ < 100 °C IBP = 2 mA 0 °C < TJ < 100 °C TJ = 25 °C VBP = 5.9 V 5.7 5.9 0.85 6.0 40 6.4 13 www.powerint.com Rev. D 08/11 LNK403-409/413-419 Parameter Control Functions (cont.) Symbol Conditions SOURCE = 0 V; TJ = -20 °C to 125 °C (Unless Otherwise Specified) Min Typ Max Units ICD2 Drain Supply Current ICD1 VOLTAGE MONITOR Pin Line Brown-In Threshold Current Line Brown-Out Threshold Current Line Brown-In/Out Hysteresis Line Overvoltage Threshold VOLTAGE MONITOR Pin Voltage VOLTAGE MONITOR Pin Short-Circuit Current Remote ON/OFF Threshold FEEDBACK Pin FEEDBACK Pin Current at Onset of Maximum Duty Cycle FEEDBACK Pin Current Skip Cycle Threshold Maximum Duty Cycle FEEDBACK Pin Voltage FEEDBACK Pin Short-Circuit Current IFB(DCMAXR) IFB(SKIP) DCMAX VFB IFB(SC) DC10 Duty Cycle Reduction DC40 DC60 IUV+ IUVIUV(H) 0 °C < TJ < 100 °C FET Not Switching 0 °C < TJ < 100 °C FET Switching at fOSC RR = 24.9 kW RR = 49.9 kW RR = 24.9 kW RR = 49.9 kW RR = 24.9 kW RR = 49.9 kW Threshold Hysteresis 1.0 0.9 1.3 1.5 1.6 mA 2.25 TJ = 25 °C TJ = 25 °C TJ = 25 °C TJ = 25 °C RR = 24.9 kW RR = 49.9 kW 21.0 22.8 22.5 24.5 18.5 15.0 24.0 26.2 mA mA mA 1 5 107 4 9.4 112 4 117 IOV VV IV(SC) VV(REM) mA V mA V 0 °C < TJ < 100 °C IUV- < IV < IOV VV = 5 V TJ = 25 °C TJ = 25 °C 2.75 170 0.5 3.0 190 3.25 210 0 °C < TJ < 100 °C 0 °C < TJ < 100 °C IFB(DCMAXR) < IFB < IFB(SKIP) 0 °C < TJ < 100 °C IFB = 150 mA 0 °C < TJ < 100 °C VFB = 5 V TJ = 25 °C IFB = IFB(AR), TJ = 25 °C, See Note B IFB = 40 mA, TJ = 25 °C IFB = 60 mA, TJ = 25 °C 220 90 2.08 320 10 20 36 2.40 400 85 mA mA 99.9 2.62 480 % V mA % 14 Rev. D 08/11 www.powerint.com LNK403-409/413-419 Conditions SOURCE = 0 V; TJ = -20 °C to 125 °C (Unless Otherwise Specified) TJ = 25 °C VBP = 5.9 V TJ = 25 °C TJ = 25 °C See Note B 0 °C < TJ < 100 °C Parameter Auto-Restart Auto-Restart ON-Time Auto-Restart Duty Cycle SOA Minimum Switch ON-Time FEEDBACK Pin Current During Auto-Restart REFERENCE Pin REFERENCE Pin Voltage REFERENCE Pin Current Symbol Min Typ Max Units tAR DCAR tON(SOA) IFB(AR) 40 3.1 1.75 17.5 ms % ms mA VR IR RR = 24.9 kW 0 °C < TJ < 100 °C 1.215 48.45 1.245 49.70 1.275 50.95 V mA Current Limit/Circuit Protection di/dt = 174 mA/ms di/dt = 174 mA/ms Full Power Current Limit (CBP = 100 mF) ILIMIT(F) TJ = 25 °C di/dt = 225 mA/ms di/dt = 320 mA/ms di/dt = 350 mA/ms di/dt = 426 mA/ms di/dt = 133 mA/ms di/dt = 195 mA/ms Reduced Power Current Limit (CBP = 10 mF) ILIMIT(R) TJ = 25 °C di/dt = 192 mA/ms di/dt = 240 mA/ms di/dt = 335 mA/ms di/dt = 380 mA/ms di/dt = 466 mA/ms Minimum ON-Time Pulse Leading Edge Blanking Time Current Limit Delay Thermal Shutdown Temperature Thermal Shutdown Hysteresis BYPASS Pin Power-Up Reset Threshold Voltage VBP(RESET) 0 °C < TJ < 100 °C 2.25 tLEB + tIL(D) tLEB tIL(D) LNK404, LNK414 LNK405, LNK415 LNK406, LNK416 LNK407, LNK417 LNK408, LNK418 LNK409, LNK419 LNK403, LNK413 LNK404, LNK414 LNK405, LNK415 LNK406, LNK416 LNK407, LNK417 LNK408, LNK418 LNK409, LNK419 1.02 1.24 1.50 1.77 2.39 3.26 0.75 0.81 1.00 1.19 1.42 1.73 2.35 300 150 150 135 142 75 3.5 4.25 150 500 1.18 1.44 1.74 2.06 2.77 3.79 0.85 0.94 1.16 1.38 1.66 2.01 2.73 700 500 ns ns ns °C °C V A A TJ = 25 °C TJ = 25 °C See Note B TJ = 25 °C See Note B 15 www.powerint.com Rev. D 08/11 LNK403-409/413-419 Parameter Output Symbol Conditions SOURCE = 0 V; TJ = -20 °C to 125 °C (Unless Otherwise Specified) Min Typ Max Units LNK403, LNK413 ID = 100 mA LNK404, LNK414 ID = 100 mA LNK405, LNK415 ID = 150 mA ON-State Resistance RDS(ON) LNK406, LNK416 ID = 150 mA LNK407, LNK417 ID = 200 mA LNK408, LNK418 ID = 250 mA LNK409, LNK419 ID = 350 mA OFF-State Drain Leakage Current Breakdown Voltage Minimum Drain Supply Voltage Rise Time Fall Time tR tF IDSS BVDSS TJ = 25 °C TJ = 100 °C TJ = 25 °C TJ = 100 °C TJ = 25 °C TJ = 100 °C TJ = 25 °C TJ = 100 °C TJ = 25 °C TJ = 100 °C TJ = 25 °C TJ = 100 °C TJ = 25 °C TJ = 100 °C 9.00 13.50 5.40 8.35 4.10 6.30 2.80 4.10 2.00 3.10 1.60 2.40 1.40 2.1 10.35 15.5 6.25 9.7 4.7 7.3 3.2 4.75 2.3 3.6 1.85 2.8 1.6 2.45 50 mA V V W VBP = 6.4 V VDS = 560 V TJ = 100 °C VBP = 6.4 V TJ = 25 °C TJ < 100 °C Measured in a Typical Flyback 725 36 100 50 ns ns NOTES: A. For specifications with negative values, a negative temperature coefficient corresponds to an increase in magnitude with increasing temperature and a positive temperature coefficient corresponds to a decrease in magnitude with increasing temperature. B. Guaranteed by characterization. Not tested in production. 16 Rev. D 08/11 www.powerint.com LNK403-409/413-419 Typical Performance Characteristics PI-5992-101110 DRAIN Capacitance (pF) 100 Power (mW) 1000 Scaling Factors: LNK403, LNK413 LNK404, LNK414 LNK405, LNK415 LNK406, LNK416 LNK407, LNK417 LNK408, LNK418 LNK409, LNK419 0.18 0.28 0.38 0.56 0.75 1.00 1.16 200 Scaling Factors: LNK403, LNK413 LNK404, LNK414 LNK405, LNK415 LNK406, LNK416 LNK407, LNK417 LNK408, LNK418 LNK409, LNK419 0.18 0.28 0.38 0.56 0.75 1.00 1.16 100 0 0 100 200 300 400 500 600 0 0 100 200 300 400 500 600 700 DRAIN Pin Voltage (V) Figure 14. Drain Capacitance vs. Drain Pin Voltage. DRAIN Voltage (V) Figure 15. Power vs. Drain Voltage. DRAIN Current (Normalized to Absolute Maximum Rating) DRAIN Current (A) 4 3 2 1 1 0.8 0.6 0.4 0.2 Scaling Factors: LNK403, LNK413 LNK404, LNK414 LNK405, LNK415 LNK406, LNK416 LNK407, LNK417 LNK408, LNK418 LNK409, LNK419 0.18 0.28 0.38 0.56 0.75 1.00 1.16 LNK408 TCASE = 25 °C LNK408 TCASE = 100 °C 0 0 2 4 6 8 10 12 14 16 18 20 0 0 100 200 300 400 500 600 700 800 DRAIN Voltage (V) Figure 16. Drain Current vs. Drain Voltage. DRAIN Voltage (V) Figure 17. Maximum Allowable Drain Current vs. Drain Voltage. PI-6010-060410 PI-5994-101110 5 1.2 PI-5993-101110 10000 300 17 www.powerint.com Rev. D 08/11 LNK403-409/413-419 eSIP-7C (E Package) 2 A B C 0.403 (10.24) 0.397 (10.08) 0.081 (2.06) 0.077 (1.96) 0.264 (6.70) Ref. 2 Detail A 0.290 (7.37) Ref. 0.519 (13.18) Ref. 0.140 (3.56) 0.120 (3.05) 0.070 (1.78) Ref. 0.050 (1.27) 3 0.325 (8.25) 0.320 (8.13) 0.198 (5.04) Ref. Pin #1 I.D. 0.016 (0.41) Ref. 0.047 (1.19) 0.207 (5.26) 0.187 (4.75) 3 4 0.016 (0.41) 6× 0.011 (0.28) 0.020 M 0.51 M C 0.100 (2.54) 0.118 (3.00) SIDE VIEW 0.033 (0.84) 6× 0.028 (0.71) 0.010 M 0.25 M C A B BACK VIEW FRONT VIEW 10° Ref. All Around 0.021 (0.53) 0.019 (0.48) 0.060 (1.52) Ref. 0.020 (0.50) PIN 1 0.048 (1.22) 0.046 (1.17) 0.019 (0.48) Ref. 0.023 (0.58) END VIEW Notes: 1. Dimensioning and tolerancing per ASME Y14.5M-1994. 2. Dimensions noted are determined at the outermost extremes of the plastic body exclusive of mold flash, tie bar burrs, gate burrs, and interlead flash, but including any mismatch between the top and bottom of the plastic body. Maximum mold protrusion is 0.007 [0.18] per side. 3. Dimensions noted are inclusive of plating thickness. 4. Does not include inter-lead flash or protrusions. 5. Controlling dimensions in inches (mm). 0.027 (0.70) 0.100 (2.54) 0.050 (1.27) 0.050 (1.27) 0.378 (9.60) Ref. 0.059 (1.50) 0.155 (3.93) PIN 7 0.059 (1.50) DETAIL A 0.100 (2.54) 0.100 (2.54) MOUNTING HOLE PATTERN (not to scale) PI-4917-061510 18 Rev. D 08/11 www.powerint.com LNK403-409/413-419 eSIP-7F (L Package) 2 A B C 0.403 (10.24) 0.397 (10.08) 0.081 (2.06) 0.077 (1.96) Detail A 0.264 (6.70) Ref. 2 0.325 (8.25) 0.320 (8.13) 3 0.290 (7.37) Ref. 0.016 (0.41) 6× 0.011 (0.28) 0.020 M 0.51 M C 1 7 0.490 (12.45) Ref. 0.198 (5.04) Ref. Pin 1 I.D. 0.070 (1.78) Ref. 0.050 (1.27) 0.084 (2.14) 0.047 (1.19) Ref. 0.129 (3.28) 0.122 (3.08) SIDE VIEW 0.173 (4.40) 0.163 (4.15) 7 1 0.089 (2.26) 0.079 (2.01) 0.100 (2.54) 0.033 (0.84) 6× 0.028 (0.71) 0.010 M 0.25 M C A B TOP VIEW Exposed pad up Notes: 1. Dimensioning and tolerancing per ASME Y14.5M-1994. 2. Dimensions noted are determined at the outermost extremes of the plastic body exclusive of mold flash, tie bar burrs, gate burrs, and interlead flash, but including any mismatch between the top and bottom of the plastic body. Maximum mold protrusion is 0.007 [0.18] per side. 3. Dimensions noted are inclusive of plating thickness. 4. Does not include inter-lead flash or protrusions. 5. Controlling dimensions in inches (mm). 3 4 BOTTOM VIEW Exposed pad hidden 0.060 (1.52) Ref. 1 7 0.021 (0.53) 0.019 (0.48) 0.020 (0.50) 0.019 (0.48) Ref. 0.378 (9.60) Ref. END VIEW 0.048 (1.22) 0.046 (1.17) 0.023 (0.58) 0.027 (0.70) DETAIL A (Not drawn to scale) PI-5204-061510 Part Ordering Information • LinkSwitch Product Family • PH Series Number • Package Identifier E L LNK 409 EG G eSIP-7C eSIP-7F GREEN: Halogen Free and RoHS Compliant • Package Material 19 www.powerint.com Rev. D 08/11 Revision A B C D Notes Initial Release. Updated Power Table. Added Non-Dimming Parts and Related Text. Added L Package. Date 06/09/10 08/06/10 11/10 08/11 For the latest updates, visit our website: www.powerint.com Power Integrations reserves the right to make changes to its products at any time to improve reliability or manufacturability. Power Integrations does not assume any liability arising from the use of any device or circuit described herein. POWER INTEGRATIONS MAKES NO WARRANTY HEREIN AND SPECIFICALLY DISCLAIMS ALL WARRANTIES INCLUDING, WITHOUT LIMITATION, THE IMPLIED WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE, AND NON-INFRINGEMENT OF THIRD PARTY RIGHTS. Patent Information The products and applications illustrated herein (including transformer construction and circuits external to the products) may be covered by one or more U.S. and foreign patents, or potentially by pending U.S. and foreign patent applications assigned to Power Integrations. A complete list of Power Integrations patents may be found at www.powerint.com. Power Integrations grants its customers a license under certain patent rights as set forth at http://www.powerint.com/ip.htm. Life Support Policy POWER INTEGRATIONS PRODUCTS ARE NOT AUTHORIZED FOR USE AS CRITICAL COMPONENTS IN LIFE SUPPORT DEVICES OR SYSTEMS WITHOUT THE EXPRESS WRITTEN APPROVAL OF THE PRESIDENT OF POWER INTEGRATIONS. As used herein: 1. A Life support device or system is one which, (i) is intended for surgical implant into the body, or (ii) supports or sustains life, and (iii) whose failure to perform, when properly used in accordance with instructions for use, can be reasonably expected to result in significant injury or death to the user. 2. A critical component is any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness. The PI logo, TOPSwitch, TinySwitch, LinkSwitch, DPA-Switch, PeakSwitch, CAPZero, SENZero, LinkZero, HiperPFS, HiperTFS, HiperLCS, Qspeed, EcoSmart, Clampless, E-Shield, Filterfuse, StakFET, PI Expert and PI FACTS are trademarks of Power Integrations, Inc. Other trademarks are property of their respective companies. ©2011, Power Integrations, Inc. Power Integrations Worldwide Sales Support Locations World Headquarters 5245 Hellyer Avenue San Jose, CA 95138, USA. Main: +1-408-414-9200 Customer Service: Phone: +1-408-414-9665 Fax: +1-408-414-9765 e-mail: usasales@powerint.com China (Shanghai) Rm 1601/1610, Tower 1, Kerry Everbright City No. 218 Tianmu Road West, Shanghai, P.R.C. 200070 Phone: +86-21-6354-6323 Fax: +86-21-6354-6325 e-mail: chinasales@powerint.com China (ShenZhen) 3rd Floor, Block A, Zhongtou International Business Center, No. 1061, Xiang Mei Rd, FuTian District, ShenZhen, China, 518040 Phone: +86-755-8379-3243 Fax: +86-755-8379-5828 e-mail: chinasales@powerint.com Germany Rueckertstrasse 3 D-80336, Munich Germany Phone: +49-89-5527-3910 Fax: +49-89-5527-3920 e-mail: eurosales@powerint.com India #1, 14th Main Road Vasanthanagar Bangalore-560052 India Phone: +91-80-4113-8020 Fax: +91-80-4113-8023 e-mail: indiasales@powerint.com Italy Via De Amicis 2 20091 Bresso MI Italy Phone: +39-028-928-6000 Fax: +39-028-928-6009 e-mail: eurosales@powerint.com Japan Kosei Dai-3 Bldg. 2-12-11, Shin-Yokomana, Kohoku-ku Yokohama-shi Kanagwan 222-0033 Japan Phone: +81-45-471-1021 Fax: +81-45-471-3717 e-mail: japansales@powerint.com Korea RM 602, 6FL Korea City Air Terminal B/D, 159-6 Samsung-Dong, Kangnam-Gu, Seoul, 135-728, Korea Phone: +82-2-2016-6610 Fax: +82-2-2016-6630 e-mail: koreasales@powerint.com Taiwan 5F, No. 318, Nei Hu Rd., Sec. 1 Nei Hu Dist. Taipei, Taiwan 114, R.O.C. Phone: +886-2-2659-4570 Fax: +886-2-2659-4550 e-mail: taiwansales@powerint.com Europe HQ 1st Floor, St. James’s House East Street, Farnham Surrey GU9 7TJ United Kingdom Phone: +44 (0) 1252-730-141 Fax: +44 (0) 1252-727-689 e-mail: eurosales@powerint.com Applications Hotline World Wide +1-408-414-9660 Singapore 51 Newton Road Applications Fax #15-08/10 Goldhill Plaza World Wide +1-408-414-9760 Singapore, 308900 Phone: +65-6358-2160 Fax: +65-6358-2015 e-mail: singaporesales@powerint.com
LNK417EG 价格&库存

很抱歉,暂时无法提供与“LNK417EG”相匹配的价格&库存,您可以联系我们找货

免费人工找货
LNK417EG
    •  国内价格 香港价格
    • 48+12.0953548+1.46520
    • 192+12.03883192+1.45836
    • 480+12.03857480+1.45833
    • 1200+12.038301200+1.45829
    • 1920+12.038031920+1.45826

    库存:480

    LNK417EG

      库存:528