05113
Only One Name Means ProTek’Tion™
30KPA30A - 30KPA360A
30kW PoWeR tvs comPonent DescRiPtion
The 30KPA Series, are discrete 30,000 Watt, silicon transient voltage suppressors (TVS) designed for use in applications where large voltage transients can permanently damage voltage sensitive components and equipment. The 30KPA series is available in voltages ranging from 30V to 360V with 5 percent and 10 percent tolerances. Both tolerances are referenced to the power supply output or operating voltage level. This series is compatible with IEC 61000-4-5 (Surge) requirements.
AXiAl leAD PAcKAGe FeAtuRes
• Compatible with IEC 61000-4-5 (Surge): 48A, 8/20µs - L3(LineGround), L4(Line-Line) & L1 (Power) • 30,000 Watts Peak Pulse Power per Line (tp = 10/1000µs) • Unidirectional and Bidirectional Configurations • Easy Mounting to Printed Circuit Board • tClamping (0V to VBR Min.) < 1 x 10-12 seconds theoretical (Unidirectional) and < 5ns (Bidirectional) • Available in Multiple Voltages Ranging From 30V to 360V • RoHS Complaint (Exemption #7)
APPlicAtions
• • • • Relay Drives Motor (Start/Stop) Back EMF Protection Module Lightning Protection Secondary Lightning Protection for AC/DC
mechAnicAl chARActeRistics
• • • • Molded Case Approximate Weight: 5 grams Lead-Free Pure-Tin Plating (Annealed) Solder Reflow Temperature: Pure-Tin - Sn, 100: 260-270°C • Flammability Rating UL 94V-0
ciRcuit DiAGRAms
UNIDIRECTIONAL
BIDIRECTIONAL
05113.R23 3/11
Page 1
www.protekdevices.com
05113
Only One Name Means ProTek’Tion™
30KPA30A - 30KPA360A
tyPicAl Device chARActeRistics
mAXimum RAtinGs @ 25°c unless otherwise specified
PARAmeteR
Peak Pulse Power (tp = 10/1000µs) - See Figure 1 Forward Surge Rating - 1/120 seconds - See Note 2 Steady State Power Dissipation Storage Temperature Operating Temperature
symBol
PPP IF PP TSTG TL
vAlue
30,000 200 8.0 -55 to 150 -55 to 150
units
Watts Amps Watts °C °C
electRicAl chARActeRistics PeR line @ 25°c unless otherwise specified
PARt numBeR (notes 1 - 2) RAteD stAnD-oFF voltAGe vWm volts
30KPA30A 30KPA33A 30KPA36A 30KPA43A 30KPA48A 30KPA58A 30KPA64A 30KPA70A 30KPA75A 30KPA85A 30KPA90A 30KPA100 30KPA100A 30KPA130A 30KPA160A 30KPA170A 30KPA180A 30KPA220A 30KPA250A 30KPA260A 30KPA280A 30KPA300A 30KPA320A 30KPA360A notes 30.0 33.0 36.0 43.0 48.0 58.0 64.0 70.0 75.0 85.0 90.0 100.0 100.0 130.0 160.0 170.0 180.0 220.0 250.0 260.0 280.0 300.0 320.0 360.0
BReAKDoWn voltAGe min v(BR) volts
33.3 36.7 40.0 47.8 53.3 64.4 71.1 77.8 83.3 94.4 100.0 111.0 111.0 144.0 178.0 189.0 200.0 245.0 277.0 289.0 311.0 334.0 356.0 400.0
mAXimum leAKAGe cuRRent @i t mA
50 50 50 50 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5
@v Wm iD µA
5000 5000 2000 1000 250 20 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10
mAXimum clAmPinG voltAGe (Fig. 2) @ 10/1000µs vc @ i PP
55.2V @ 543.0A 58.6V @ 512.0A 61.8V @ 485.0A 73.0V @ 410.0A 77.4V @ 388.0A 92.4V @ 325.0A 104.0V @ 294.0A 109.0V @ 274.0A 119.4V @ 251.0A 139.0V @ 216.0A 147.0V @ 206.0A 179.0V @ 168.0A 162.0V @ 186.0A 209.0V @ 142.0A 252.6V @ 119.0A 274.0V @ 110.0A 291.0V @ 104.0A 356.0V @ 84.0A 404.0V @ 74.0A 416.0V @ 72.0A 464.0V @ 65.0A 484.0V @ 62.0A 530.0V @ 57.0A 640.0V @ 55.0A
temPeRAtuRe coeFFicient oF v(BR) qv(BR) mv/°c
34 39 41 50 56 68 76 83 89 105 109 134 121 157 195 207 230 269 314 317 342 368 370 380
1. Part numbers shown are unidirectional devices. Add a “CA” suffix to specify bidirectional devices, such as 30KPA30cA. 2. VF = 15 Volts @ 200A, 8.3ms(1/2 Sine Wave) - Unidirectional devices only.
05113.R23 3/11
Page 2
www.protekdevices.com
05113
Only One Name Means ProTek’Tion™
30KPA30A - 30KPA360A
tyPicAl Device chARActeRistics
FiGuRe 1 PeAK Pulse PoWeR vs Pulse time
1,000
PPP - Peak Pulse Power - kilowatts
100
30kW, 10/1000µs Waveform
10
1 0.1
1
10
100 td - Pulse Duration - µs
1,000
10,000
100,000
FiGuRe 2 Pulse WAveFoRm
tf
iPP - Peak Pulse current - % of iPP 100 100
FiGuRe 3 PoWeR DeRAtinG cuRve
TEST WAVEFORM PARAMETERS tf = 10µs td = 1000µs Peak Pulse Power 10/1000µs
80 % of Rated Power
Peak Value IPP td = t/(IPP/2)
50
60
40
20
e
0 0 1
-t
2 t - time - ms
3
0
0
25
50
75
100
125
150
tl - lead temperature - °c
05113.R23 3/11
Page 3
www.protekdevices.com
05113
Only One Name Means ProTek’Tion™
30KPA30A - 30KPA360A
AXiAl leAD PAcKAGe inFoRmAtion
outline Dimensions
Dim
A B C D E notes
millimeteRs min
24.5 8.60 24.5 1.20 DIA. 8.60
inches min
1.00 0.34 1.00 0.048 DIA. 0.34
mAX
9.10 1.30 DIA. 9.10
mAX
0.36 0.052 DIA. 0.36
A
E
1. Dimensions are exclusive of mold flash and metal burrs.
B
C D
oRDeRinG inFoRmAtion
BAse PARt numBeR (xx = voltage)
30KPAxx 30KPAxxA 30KPAxxCA notes
leADFRee suFFiX
-LF -LF -LF
tAPe suFFiX
n/a n/a n/a
Qty/Reel
n/a n/a n/a
Reel siZe
n/a n/a n/a
tuBe Qty
n/a n/a n/a
1. Marking on Part - logo, part number, date code and positive terminal marked with band(unidirectional only).
mARKinG DiAGRAm
30KPAxxx
yyww
P
Package outline per document number 06028.R2 9/09.
05113.R23 3/11
Page 4
www.protekdevices.com
05113
Only One Name Means ProTek’Tion™
30KPA30A - 30KPA360A
comPAny inFoRmAtion
comPAny PRoFile ProTek Devices, based in Tempe, Arizona USA, is a manufacturer of Transient Voltage Suppression (TVS) products designed specifically for the protection of electronic systems from the effects of lightning, Electrostatic Discharge (ESD), Nuclear Electromagnetic Pulse (NEMP), inductive switching and EMI/RFI. With over 25 years of engineering and manufacturing experience, ProTek designs TVS devices that provide application specific protection solutions for all electronic equipment/systems. ProTek Devices Analog Products Division, also manufactures analog interface, control, RF and power management products. contAct us corporate headquarters 2929 South Fair Lane Tempe, Arizona 85282 USA By telephone General: 602-431-8101 Sales: 602-414-5109 Customer Service: 602-414-5114 By Fax General: 602-431-2288 By e-mail: Sales: sales@protekdevices.com Customer Service: service@protekdevices.com Technical Support: support@protekdevices.com Web www.protekdevices.com www.protekanalog.com
COPYRIGHT © ProTek Devices 2007 - This literature is subject to all applicable copyright laws and is not for resale in any manner. SPECIFICATIONS: ProTek reserves the right to change the electrical and or mechanical characteristics described herein without notice. DESIGN CHANGES: ProTek reserves the right to discontinue product lines without notice and that the final judgement concerning selection and specifications is the buyer’s and that in furnishing engineering and technical assistance. ProTek assumes no responsibility with respect to the selection or specifications of such products. ProTek makes no warranty, representation or guarantee regarding the suitability of its products for any particular purpose, nor does ProTek assume any liability arising out of the application or use of any product or circuit and specifically disclaims any and all liability without limitation special, consequential or incidental damages. LIFE SUPPORT POLICY: ProTek Devices products are not authorized for use in life support systems without written consent from the factory.
05113.R23 3/11
Page 5
www.protekdevices.com
很抱歉,暂时无法提供与“30KPA64A”相匹配的价格&库存,您可以联系我们找货
免费人工找货