05026
60KS200C
thru
90KS200C
SHIPBOARD/ AC POWER BUS VOLTAGE SUPPRESSOR
APPLICATIONS
✔ AC Power Protection ✔ Shipboard (Line-Line) Protection ✔ Differential AC Power Bus ✔ Aircraft AC Power Bus
IEC COMPATIBILITY ( EN61000-4)
✔ Meets the Following Military Specifications: - DOD-STD-1399 - MIL-STD-704A ✔ 60 & 90 kilowatts Peak Pulse Power per Line (tp=1.2/50µs) ✔ Each Device 100% Tested ✔ 200 Volts Bidirectional
60KS200C
MECHANICAL CHARACTERISTICS
✔ Hermetically Sealed Glass to Metal Sub-Assemblies ✔ Weight 50 grams (Approximate) ✔ Flammability Rating UL 94V-0 ✔ Device Marking: Logo & Part Number ✔ Screening Available Upon Request - The 60 & 90KS series can be screened upon request for military requirements in accordance with MIL-PRF-19500 (applicable test). Standard screening is available based on the following options: H1 - Submodule Screening per test plans 05231 & 05232 H2 - Submodule & Module Screening per test plan 05233 H3 - Submodule & Module Screening, Module Group B & C Lot Testing per test plans 05234 & 05235
90KS200C
MAXIMUM RATINGS @ 25°C Unless Otherwise Specified
PARAMETER
Peak Pulse Power (tp = 1.2/50µs) - See Fig. 1 Operating Temperature Storage Temperature Steady State Power Disspiation @ 50°C
SYMBOL
PPP TL TSTG TA
VALUE
60 & 90 -55 to 150 -55 to 150 10.0
UNITS
kilowatts °C °C Amps
05026.R6 2/07
1
www.protekdevices.com
60KS200C
thru
90KS200C
DEVICE CHARACTERISTICS
ELECTRICAL CHARACTERISTICS PER LINE
PART NUMBER RATED STAND-OFF VOLTAGE MINIMUM BREAKDOWN VOLTAGE @ 25°C Unless Otherwise Specified MAXIMUM LEAKAGE CURRENT MAXIMUM PEAK PULSE CURRENT (See Fig. 2)
MAXIMUM CLAMPING VOLTAGE (See Fig. 2) @ IPP VC VOLTS 335 280
@1mA VWM VOLTS 60KS200C 90KS200C 180 180
V(BR)
VOLTS 200 200
@V WM ID µA 10 0.5
IPPM AMPS 180 180
1000
FIGURE 1 PEAK PULSE POWER VS PULSE TIME
PPP - Peak Pulse Power - killowatts
90kW 1.2/50µs Waveform 100 60kW 1.2/50µs Waveform
10
1
0.1
1
10
100 td - Pulse Duration - µs
1000
10000
FIGURE 2 PULSE WAVE FORM
100
IPP - Peak Pulse Current - % of IPP
100
FIGURE 3 POWER DERATING CURVE
Peak Pulse Power 1.2/50µs 80
% Of Rated Power
tf Peak Value IPP
TEST WAVEFORM PARAMETERS tf = 1.2µs td = 50µs
60
td = t IPP/2 50
40
20
e-t 0 0 50 100 t - Time - ms 150
0 0 25
Average Power 50 75 100 125 TL - Lead Temperature - °C 150
05026.R6 2/07
2
www.protekdevices.com
60KS200C
thru
90KS200C
PACKAGE OUTLINE & DIMENSIONS
60KS200C PACKAGE OUTLINE 60KS200C
A C B
D G
H
DIMENSIONS DIM A B C D* E F* G H I* J MILLIMETERS MIN MAX 56.38 49.02 3.43 20.32 8.26 3.18 DIA 16.76 34.16 6.35 11.94 57.91 50.03 4.17 20.32 9.27 3.18 DIA 18.29 35.69 6.35 13.46 90KS200C INCHES MIN MAX 2.28 2.22 1.93 1.97 0.165 0.135 0.800 0.800 0.325 0.365 0.125 DIA 0.125 DIA 0.660 0.720 1.405 1.345 0.250 0.250 0.470 0.530
E
F
J
I
90KS200C PACKAGE OUTLINE
A C B
D G
H
DIMENSIONS DIM A B C D E F G H I J MILLIMETERS MIN MAX 47.75 6.10 24.89 4.90 DIA 22.66 45.34 6.48 63.50 48.77 6.60 25.91 10.16 5.21 DIA 23.06 46.10 7.49 13.97 INCHES MIN MAX 2.50 1.880 1.920 0.240 0.260 0.980 1.020 0.400 0.193 DIA 0.205 DIA 0.892 0.908 1.785 1.815 0.255 0.295 0.550
E
F
J I
Outline & Dimensions: Rev 0 - 4/02, 06033
Note*: Dimensions are nominal.
COPYRIGHT © ProTek Devices 2007 SPECIFICATIONS: ProTek reserves the right to change the electrical and or mechanical characteristics described herein without notice (except JEDEC). DESIGN CHANGES: ProTek reserves the right to discontinue product lines without notice, and that the final judgement concerning selection and specifications is the buyer’s and that in furnishing engineering and technical assistance, ProTek assumes no responsibility with respect to the selection or specifications of such products.