05017
CX12
thru
CX12LC
COAXIAL PROTECTOR
APPLICATIONS
✔ High Speed Video Camera ✔ Coaxial Ethernet ✔ High Speed Data Lines
IEC COMPATIBILITY ( EN61000-4)
✔ 61000-4-5 (Surge): 24A, 8/20µs - Level 2(Line-Gnd) & Level 3(Line-Line)
FEATURES
✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ BNC Connection Low Capacitance Completely Enclosed Aluminum Housing Low Clamping Voltage Nanosecond Response Time Long Life and Maintenance Free Finger Safe Connectors Fully Shielded Case
CX12 PACKAGE
FIGURE 1 TRANSIENT VOLTAGE THREAT CONDITION
2K
Current - Amperes
1K
MECHANICAL CHARACTERISTICS
✔ Metal Package ✔ Weight: 161 Grams (Approximate) ✔ Device Marking: Part Number, Logo & Date Code
0
0
20
40
60 80 Time µs
100 120 140
160
DESCRIPTION
The CX12 series is a two stage, hybrid surge protector designed to protect interfacing equipment from induced lightning or switching transients. The multistage technique has proven to be the most cost effective and reliable method for protecting sensitive electronic equipment. Employing state-ofthe-art avalanche junction diode technology, these devices provide superior performance for video, Ethernet, Token Ring or other LAN interface systems. They are in-line modules with easy interconnecting terminals. A completely enclosed aluminum housing provides EMC shielding to meet industry standard requirements. The enclosure has two female BNC type connections for easy installation. The case is grounded for those installations that require external ground connections.
FIGURE 2 CX 12LC CLAMPING VOLTAGE
Voltage - Volts
30 20 10 0 0 20 40 60 80 100 120 140 Time µs 160
Figures 1 and 2 are photographs of digitized waveforms showing a typical transient voltage and the clamping action of the CX12LC module. The device was subjected to a 2000A, 8/20µs impulse waveform in accordance with ANSI C62.36. The CX12 has an operating frequency range up to 10MHz and the CX12LC up to 100MHz.
05017.R4 12/05
1
www.protekdevices.com
CX12
thru
CX12LC
DEVICE CHARACTERISTICS
MAXIMUM RATINGS
Peak Operating Line Voltage (VOP ) Operating Line Current (IO ) Maximum Transient Voltage Maximum Transient Current Maximum Leakage Current CX12 Frequency Responce -3 dB CX12LC Frequency Responce -3 dB Operating & Storage Temperature Response Time @ 25°C
ELECTRICAL CHARACTERISTICS
PART NUMBER
MAXIMUM CLAMPING VOLTAGE Line-Ground 500A @ 8/20µs VC VOLTS CX12 CX12LC 24 28 R OHMS 3 10 MAXIMUM LINE THRUPUT RESISTANCE
@ 25°C TYPICAL CAPACITANCE
±12 V 200mA 20kV 3000A (8/20µs) 5µA @ 30MHz @ 200MHz -40° to +85°C < 10 ns
@ 0V, 1 MHz C pF 200 25
FIGURE 4 PULSE WAVE FORM
120
IPP - Peak Pulse Current - % Of IPP
100 80 60 40 20 0
t f
Peak Value IPP -t e
TEST WAVEFORM PARAMETERS tf = 8µs td = 20µs
FIGURE 3 LINEAR VS NON-LINEAR CAPACITANCE
1000
td = t IPP/2
Industry Standard Low Capcitance Solid State Protector
C - Capacitance - pF
100
0
5
10
15 20 t - Time - µs
25
30
FIGURE 5 FREQUENCY RESPONCE CX12
ProTeks Device
10
0
2 4 6 8 10 VOP - Data Line Operating Voltage - Volts
FIGURE 6 FREQUENCY RESPONCE CX12LC
Figure 3 shows a comparison of capacitance between a industrial standard device (Top Line) and the ProTek Device CX12LC (Bottom Line). Due to the drastic change in the capacitance of the product (Top Line), signal distortion, loss of data or even access into the computer may be a problem.
05017.R4 12/05
2
www.protekdevices.com
CX12
thru
CX12LC
PACKAGE OUTLINE & DIMENSIONS
INST ALLA TION
1.21 (30.73 mm)
1.10 (27.94 mm) 1.40 (35.56 mm)
The CX12 series is designed with a female BNC type connector on both ends for easy installation. Disconnect the video or data line from the sensitive equipment. Insert the CX12 in the line near the AC power outlet of the equipment to be protected. Install a cable in between the CX12 and the equipment to be protected. Attach a ground wire between the case of the CX12 and the equipment AC power ground, or to the coax shield as required.
1.10 (27.94 mm) 0.15 (3.81 mm) 0.72 (18.29 mm)
EQUIPMENT
COPYRIGHT © ProTek Devices 2003 SPECIFICATIONS: ProTek reserves the right to change the electrical and or mechanical characteristics described herein without notice (except JEDEC). DESIGN CHANGES: ProTek reserves the right to discontinue product lines without notice, and that the final judgement concerning selection and specifications is the buyer’s and that in furnishing engineering and technical assistance, ProTek assumes no responsibility with respect to the selection or specifications of such products.
05017.R4 12/05
LINE
CAUTION:Mounting plate must be connected to earth ground
0.150 DIA. (3.81 mm) Mounting Holes
CX 12 - COAXIAL LINE PROTECTOR
2.95 (74.93 mm) 3.25 (82.55 mm)
2.25 (57.15 mm)
0.70(17.78 mm)
0.72 (18.29 mm)
ProTek Devices 2929 South Fair Lane, Tempe, AZ 85282 Tel: 602-431-8101 Fax: 602-431-2288 E-Mail: sales@protekdevices.com Web Site: www.protekdevices.com
www.protekdevices.com
3