EW N Issue 1, 28 August 2007 Radiometrix Hartcran House, 231 Kenton Lane, Harrow, HA3 8RP, England Tel: +44 (0) 20 8909 9595, Fax: +44 (0) 20 8909 2233 SMX1 Small MultiSmall Multi-channel VHF Transceiver UK variant: SMX1-173-5 (10mW) Non-UK variant: SMX1-XXX-5 (1mW-50mW) SMX1 is small multi-channel VHF transceiver operating on 173.200MHz173.325MHz band. It is also available on 151MHz band Australian allocation. SMX1 offers a fast-route to custom frequency on any VHF band from 130MHz to 180MHz with 25kHz channel spacing. Features ! ! ! ! ! ! ! ! ! ! Conforms to ETSI EN 300 220-3 and EN 301 489-3 Conforms to Australian/New Zealand AS/NZS 4268:2003 High performance double superhet, 128 channel PLL synthesizer Data rates up to 5 kbps for standard module Usable range over 1km Fully screened. Low profile Feature-rich interface (RSSI, analogue and digital baseband) Incorporate a 1200baud dumb modem Re-programmable via RS232 interface Low power requirements Figure 1: SMX1-173-5 Applications ! ! ! ! ! ! ! ! Handheld terminals Heavy vehicle/machine remote controls EPOS equipment, barcode scanners Data loggers Industrial telemetry and telecommand In-building environmental monitoring and control High-end security and fire alarms Vehicle data up/download Technical Summary ! ! ! ! ! ! ! ! ! Operating frequency: 173.200 – 173.325MHz (UK), 150.825 – 152.450MHz (Australia) Custom variants from 130 – 180MHz on any 1MHz band 128 channels controlled via RS232 interface Transmit power: +10dBm (10mW) nominal. Adjustable 1 – 50mW Supply range: 4.2V - 16V Current consumption: 40mA (10mW) - 65mA (50mW) transmit, 20mA receive Data bit rate: 5kbps max. (standard module) Receiver sensitivity: -120dBm (for 12 dB SINAD) Size: 53 x 32 x 12mm Radiometrix Ltd SMX1 Data Sheet page 1 Radiometrix Ltd SMX1 Data Sheet Figure 2: SMX1 block diagram page 2 Figure 3: SMX1 footprint (Top) view Pin Description Pin 1a 2a 3a 4a 5a 6a 7a 8a 1b 2b 3b 4b Name RSSI Vcc TXD AF out RXD TXE PGM 0V 0V S0 S1 S2 Function DC level between 0.5V and 2.5V. 60dB dynamic range DC supply input. (4.2 – 16V at 40mA nominal) DC coupled input for TTL/ CMOS logic. 500mV p-p audio. DC coupled, approx 0.8V bias. Open collector output of data slicer. Need external pull-up Transmit enable. Low = RX mode. High = TX. (10k pull down) Serial programming / control input (true RS232) Ground Ground Parallel channel select LSB Parallel channel select Parallel channel select MSB Pin description of SMX1 with Modem mode selected The 'modem' mentioned is a 1200 baud RS232 semi-intelligent unit (Transmit keyed when valid serial data is present, so no separate TX control needed. Coding in the datastream also permits the receiver to ignore noise and only output valid serial data) This is a half duplex unit, so collisions between transmitted and received packets must be dealt with by the user (if transmit data is sent to the unit then a transmit burst commences immediately and the contents of the receive data buffer is lost) Pin 1a 2a 3a 4a 5a 6a 7a 8a 1b 2b 3b 4b NOTES: 1. 2. 3. 4. No inversion occurs between TXD and RXD. However AF out is inverted relative to TXD. Parallel channel selects are active LOW and have internal pullups to 4V There are no pullups on the open collector outputs. The software incorporates a 1200 baud modem, compatible with that implemented in other Radiometrix narrowband units ( i1200 tones and format ). Modem operation is selected by the SETMOD command. TXE pin (6a) becomes an RS232 input, and RS232 compatible data is output on the RXD pin (5a). If true +/- levels are desired then an inverter and a MAX232 should be used on data out. SMX1 Data Sheet page 3 Name RSSI Vcc NC NC MOD RXD MOD TXD PGM 0V 0V S0 S1 S2 Function DC level between 0.5v and 2.5v. 60dB dynamic range DC supply input. (4.2 - 16v at 40mA nom.) Leave unconnected Leave unconnected Open collector RS232 compatible data output RS232 data input Serial programming/control input (true RS232) Ground Ground Parallel channel select LSB Parallel channel select Parallel channel select MSB Radiometrix Ltd 5. RS232 input pins (6a and 7a) tolerate true +/- levels. No buffering is required. 6. If analogue transmit modulation is needed, then connect a series 1µF cap + 500kΩ trimmer in the ‘baseband in’ circuit. Adjust trimmer for 90% of peak deviation (+/- 2.7KHz) at mean input level. 7. If parallel channel select is not wanted, the 4 pin connector 'b' can be removed 8. For UK version the following channel assignment is supplied: Channel 0 1 2 3 4 -7 8 - 127 9. Frequency (MHz) 173.250 173.275 173.300 173.325 173.225 (only used for alarm applications) 173.325 For Australian version the following channel assignment is supplied: Channel 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 - 65 Frequency (MHz) N vlaue 150.825 /LOAD 00 6033 150.850 /LOAD 01 6034 150.875 /LOAD 02 6035 150.900 /LOAD 036036 150.925 /LOAD 04 6037 150.950 /LOAD 05 6038 150.975 /LOAD 06 6039 151.000 /LOAD 07 6040 151.025 /LOAD 08 6041 151.050 /LOAD 09 6042 151.075 /LOAD 10 6043 151.100 /LOAD 11 6044 151.125 /LOAD 12 6045 151.150 /LOAD 13 6046 151.175 /LOAD 14 6047 151.200 /LOAD 15 6048 151.225 /LOADTB 6049 in sequence starting at CH 17 (151.250) Radiometrix Ltd SMX1 Data Sheet page 4 SMX1 serial interface commands 2400 baud at RS232 level. 8 bit data, no parity, 1 start bit, 1 or 2 stop bits, No flow control. Transmit (pin 3 on DB9) and Signal Ground (pin 5 on DB9) should be connected to PGM and 0V respectively. SINGLE nnnnn Set value of N for single channel operation (value not stored in eeprom) GOCHAN xx Serial select of channel xx (0 to 127) LOADMX xx Set highest permitted (serial selected) channel xx (others default to ch0) LOAD aa nnnnn Set value of N for channel aa (channels 0 to 15) LOADTB nnnnn Set value of N for channel 16 (channels 17 to 127 then in sequence) RVALUE rrrr Enter value for R register SETPAR Channel selected by 3 bit parallel input (0 to 7). Also disables modem SETSER Channel selected by most recent 'gochan' operation SETMOD Enable internal modem. Frequency selected by most recent 'gochan' or 'single' Process entry / Clear all buffers xx = channel number from 00 to 127 aa = two digit channel number from 00 to 15 nnnnn = synthesizer N register value, (up to 65535) rrrr = synthesizer R register value, (up to 16383) N= f RF f Channelspacing = 173.250 MHz = 6930 25kHz R= f Xtal f channelspacing = 13MHz , So R=520 25kHz Notes: 1. A pause of at least 50ms must be allowed between command strings (EEPROM programming time). SINGLE mode does not store the N value in EEPROM. Therefore the unit is inoperative after a power down until either another valid SINGLE command is received, or mode is changed by a GOCHAN, SETPAR or SETSER command. SINGLE mode is intended for frequency agile applications. 2. /SETPAR command should be issued at the end of channel programming to put the module back into parallel frequency select mode Radiometrix Ltd SMX1 Data Sheet page 5 Condensed specifications Frequency Frequency stability Channel spacing Number of channels Any 2MHz band from 130-180MHz 173.200 - 173.325 MHz UK std. 150.825 – 152.450MHz Australian std ±2kHz 25kHz (12.5kHz by special order) 128 channels selected via serial RS232 interface 8 channels selected via 3 frequency select pins In UK band only 173.225, 173.250, 173.275, 173.300, 173.325 MHz are used as standard; 151MHz band (Australian) unit has 66 channels 4.2V-16V 40mA (10mW); 65mA (50mW) transmit 20mA receive (or modem ‘idle’) -10 to +60 C (Storage -30 to +70 C) 53 x 32 x 12 mm Compliant with ETSI EN 300 220-3 and EN 300 686 8 pin 0.1" pitch molex 4 pin 0.1" pitch molex 3 pin 0.1" pitch molex 1.2mm (min.) ETSI Radio standard EN 300 220-3 and EMC standard EN 301 489-3 Supply voltage Current Operating temperature Size Spurious radiations Interface user Power RF Recommended PCB hole size Intended approval Transmitter Output power TX on switching time Modulation type TX modulation bandwidth Deviation Adjacent channel TX power Inputs Receiver Sensitivity image / spurious blocking adjacent channel Outputs Power on to valid audio Power on to stable data out UK standard +10dBm(10mW) ± 1dB (factory adjustable: 1 - 50mW)
SMX1-173-5
1. 物料型号: - UK变体:SMX1-173-5 (10mW) - 非UK变体:SMX1-XXX-5 (1mW-50mW)

2. 器件简介: - SMX1是一款小型多频道VHF收发器,工作频率为173.200MHz至173.325MHz,也可用于151MHz频段的澳大利亚分配。SMX1支持在130MHz至180MHz的任何VHF频段上快速定制频率,频道间隔为25kHz。

3. 引脚分配: - `la`:RSSI,动态范围60dB,0.5V至2.5V之间的直流电平。 - `2a`:Vcc,直流电源输入,4.2 - 16V,40mA名义电流。 - `3a`:TXD,TTL/CMOS逻辑的直流耦合输入。 - `4a`:AF out,500mV p-p音频,直流耦合,大约0.8V偏置。 - `5a`:RXD,数据切片器的开路输出,需要外部上拉。 - `6a`:TXE,发射使能,低电平=接收模式,高电平=发射。 - `7a`:PGM,串行编程/控制输入(真正的RS232)。 - `8a`:OV,地。 - `1b`、`2b`、`3b`、`4b`:分别为SO、S1、S2,用于并行频道选择。

4. 参数特性: - 符合ETSI EN 300 220-3和EN 301 489-3标准。 - 高性能双超外差,128频道PLL合成器。 - 数据速率最高5kbps(标准模块)。 - 使用范围超过1km。 - 完全屏蔽,低轮廓,功能丰富的接口(RSSI、模拟和数字基带)。 - 通过RS232接口重新编程。 - 低功耗要求。

5. 功能详解: - 手持终端、重型车辆/机器遥控器、EPOS设备、条形码扫描器、数据记录器、工业遥测和遥控、楼宇环境监测和控制、高端安全和火警、车辆数据上传/下载等应用。

6. 应用信息: - 同上。

7. 封装信息: - 尺寸:53 x 32 x 12mm。 - 推荐PCB孔径:至少1.2mm。 - 符合ETSI无线电标准EN 300 220-3和EMC标准EN 301 489-3。