FM24C256
256Kb FRAM Serial Memory Features
256Kbit Ferroelectric Nonvolatile RAM • Organized as 32,768 x 8 bits • High Endurance 10 Billion (1010) Read/Writes • 45 year Data Retention • NoDelay™ Writes • Advanced High-Reliability Ferroelectric Process Fast Two-wire Serial Interface • Up to 1 MHz Maximum Bus Frequency • Supports Legacy Timing for 100 kHz & 400 kHz Low Power Operation • 5V Operation • 200 µA Active Current (100 kHz) • 100 µA Standby Current Industry Standard Configuration • Industrial Temperature -40° C to +85° C • 8-pin EIAJ SOIC • “Green” Packaging Option
Description
The FM24C256 is a 256-kilobit nonvolatile memory employing an advanced ferroelectric process. A ferroelectric random access memory or FRAM is nonvolatile and performs reads and writes like a RAM. It provides reliable data retention for 45 years while eliminating the complexities, overhead, and system level reliability problems caused by EEPROM and other nonvolatile memories. The FM24C256 performs write operations at bus speed. No write delays are incurred. The next bus cycle may commence immediately without the need for data polling. In addition, the product offers write endurance orders of magnitude higher than EEPROM. Also, FRAM exhibits much lower power during writes than EEPROM since write operations do not require an internally elevated power supply voltage for write circuits. These capabilities make the FM24C256 ideal for nonvolatile memory applications requiring frequent or rapid writes. Examples range from data collection where the number of write cycles may be critical, to demanding industrial controls where the long write time of EEPROM can cause data loss. The combination of features allows more frequent data writing with less overhead for the system. The FM24C256 is available in a 8-pin EIAJ SOIC package using an industry standard two-wire protocol. Specifications are guaranteed over an industrial temperature range of -40°C to +85°C.
Pin Configuration A0 A1 A2 VSS
1 2 3 4 8 7 6 5
VDD WP SCL SDA
Pin Names A0-A2 SDA SCL WP VSS VDD
Function Device Select Address Serial Data/Address Serial Clock Write Protect Ground Supply Voltage 5V
Ordering Information
FM24C256-SE 8-pin EIAJ SOIC FM24C256-G “Green” 8-pin EIAJ SOIC NOTE: Top side part marking is “FM24C256-S” whereas “FM24C256-SE” is used only for ordering.
This product conforms specifications per the terms of the Ramtron standard warranty. The product has completed Ramtron’s internal qualification testing and has reached production status. Rev 3.1 May 2005
Ramtron International Corporation 1850 Ramtron Drive, Colorado Springs, CO 80921 (800) 545-FRAM, (719) 481-7000
www.ramtron.com
Page 1of 12
FM24C256
Counter
Address Latch
4,096 x 64 FRAM Array
8
SDA
`
Serial to Parallel Converter
Data Latch
SCL WP A0-A2 Control Logic
Figure 1. Block Diagram
Pin Description Pin Name A0-A2 Type Input Pin Description Address 2-0: These pins are used to select one of up to 8 devices of the same type on the same two-wire bus. To select the device, the address value on the three pins must match the corresponding bits contained in the device address. The address pins are pulled down internally. Write Protect: When WP is high, the entire array will be write-protected. When WP is low, all addresses may be written. This pin is internally pulled down. Serial Data/Address: This is a bi-directional input used to shift serial data and addresses for the two-wire interface. It employs an open-drain output and is intended to be wire-OR’d with other devices on the two-wire bus. The input buffer incorporates a Schmitt trigger for improved noise immunity and the output driver has slope control for falling edges. An external pull-up resistor is required. Serial Clock: The serial clock input for the two-wire interface. Data is clocked out of the device on the SCL falling edge, and clocked in on the SCL rising edge. The SCL input also incorporates a Schmitt trigger input for improved noise immunity. Supply Voltage: 5V Ground
WP SDA
Input I/O
SCL
Input
VDD VSS
Supply Supply
Rev 3.1 May 2005
Page 2 of 12
FM24C256
Overview
The FM24C256 is a serial FRAM memory. The memory array is logically organized as 32,768 x 8 bit memory array and is accessed using an industry standard two-wire interface. Functional operation of the FRAM is similar to serial EEPROMs. The major difference between the FM24C256 and a serial EEPROM relates to its superior write performance.
Two-wire Interface
The FM24C256 employs a bi-directional two-wire bus protocol using few pins and little board space. Figure 2 illustrates a typical system configuration using the FM24C256 in a microcontroller-based system. The industry standard two-wire bus is familiar to many users but is described in this section. By convention, any device that is sending data onto the bus is the transmitter while the target device for this data is the receiver. The device that is controlling the bus is the master. The master is responsible for generating the clock signal for all operations. Any device on the bus that is being controlled is a slave. The FM24C256 is always a slave device. The bus protocol is controlled by transition states in the SDA and SCL signals. There are four conditions including Start, Stop, Data bit, and Acknowledge. Figure 3 illustrates the signal conditions that specify the four states. Detailed timing diagrams are shown in the Electrical Specifications section.
VDD
Memory Architecture
When accessing the FM24C256, the user addresses 32,768 locations each with 8 data bits. These data bits are shifted serially. The 32,768 addresses are accessed using the two-wire protocol, which includes a slave address (to distinguish from other nonmemory devices), and an extended 16-bit address. Only the lower 15 bits are used by the decoder for accessing the memory. The upper address bit should be set to 0 for compatibility with higher density devices in the future. The memory is read or written at the speed of the two-wire bus. Unlike an EEPROM, it is not necessary to poll the device for a ready condition since writes occur at bus speed. By the time a new bus transaction can be shifted into the part, a write operation is complete. This is explained in more detail in the interface section below. Users can expect several obvious system benefits from the FM24C256 due to its fast write cycle and high endurance as compared with EEPROM. However there are less obvious benefits as well. For example in a high noise environment, the fast-write operation is less susceptible to corruption than an EEPROM since the write cycle is completed quickly. By contrast, an EEPROM requiring milliseconds to write is vulnerable to noise during much of the cycle. Note that the FM24C256 contains no power management circuits other than a simple internal power-on reset. It is the user’s responsibility to ensure that VDD is maintained within data sheet tolerances to prevent incorrect operation.
Microcontroller
Rmin = 1.8 KΩ Rmax = tR/Cbus
SDA
SCL
SDA
SCL
FM24C256 A0 A1 A2
FM24C64 A0 A1 A2
Figure 2. Typical System Configuration
Rev 3.1 May 2005
Page 3 of 12
FM24C256
7 Stop (Master) Start (Master)
6
0 Data bit Acknowledge (Transmitter) (Receiver)
Data bits (Transmitter)
Figure 3. Data Transfer Protocol Stop Condition A Stop condition is indicated when the bus master drives SDA from low to high while the SCL signal is high. All operations using the FM24C256 must end with a Stop condition. If an operation is pending when a Stop is asserted, the operation will be aborted. The master must have control of SDA (not a memory read) in order to assert a Stop condition. Start Condition A Start condition is indicated when the bus master drives SDA from high to low while the SCL signal is high. All read and write transactions begin with a Start condition. An operation in progress can be aborted by asserting a Start condition at any time. Aborting an operation using the Start condition will ready the FM24C256 for a new operation. If during operation the power supply drops below the specified VDD minimum, the system should issue a Start condition prior to performing another operation. Data/Address Transfer All data transfers (including addresses) take place while the SCL signal is high. Except under the two conditions described above, the SDA signal should not change while SCL is high. Acknowledge The Acknowledge takes place after the 8th data bit has been transferred in any transaction. During this state the transmitter should release the SDA bus to allow the receiver to drive it. The receiver drives the SDA signal low to acknowledge receipt of the byte. If the receiver does not drive SDA low, the condition is a No-Acknowledge and the operation is aborted. The receiver would fail to acknowledge for two distinct reasons. First is that a byte transfer fails. In this case, the No-Acknowledge ends the current operation so that the part can be addressed again. This allows the last byte to be recovered in the event of a communication error. Second and most common, the receiver does not acknowledge to deliberately end an operation. For example, during a read operation, the FM24C256 will continue to place data onto the bus as long as the receiver sends Acknowledges (and clocks). When a read operation is complete and no more data is needed, the receiver must not acknowledge the last byte. If the receiver acknowledges the last byte, this will cause the FM24C256 to attempt to drive the bus on the next clock while the master is sending a new command such as Stop. Slave Address The first byte that the FM24C256 expects after a Start condition is the slave address. As shown in Figure 4, the slave address contains the Slave ID (device type), the device select address bits, and a bit that specifies if the transaction is a read or a write. Bits 7-4 define the device type and must be set to 1010b for the FM24C256. These bits allow other types of function types to reside on the 2-wire bus within an identical address range. Bits 3-1 are the device select bits which are equivalent to chip select bits. They must match the corresponding value on the external address pins to select the device. Up to eight FM24C256 devices can reside on the same two-wire bus by assigning a different address to each. Bit 0 is the read/write bit. A 1 indicates a read operation, and a 0 indicates a write.
Slave ID 1 7 0 6 1 5 0 4 A2 3
Device Select
A1 A0 R/W 2 1 0
Figure 4. Slave Address
Rev 3.1 May 2005
Page 4 of 12
FM24C256 Addressing Overview After the FM24C256 (as receiver) acknowledges the device address, the master can place the memory address on the bus for a write operation. The address requires two bytes. The first is the MSB (upper byte). Since the device uses only 15 address bits, the value of the upper bits is a “don’t care”. Following the MSB is the LSB (lower byte) with the remaining eight address bits. The address value is latched internally. Each access causes the latched address value to be incremented automatically. The current address is the value that is held in the latch, either a newly written value or the address following the last access. The current address will be held as long as power remains or until a new value is written. Reads always use the current address. A random read address can be loaded by beginning a write operation as explained below. After transmission of each data byte, just prior to the acknowledge, the FM24C256 increments the internal address latch. This allows the next sequential byte to be accessed with no additional addressing externally. After the last address (7FFFh) is reached, the address latch will roll over to 0000h. There is no limit to the number of bytes that can be accessed with a single read or write operation. Data Transfer After the address information has been transmitted, data transfer between the bus master and the FM24C256 can begin. For a read operation the FM24C256 will place 8 data bits on the bus then wait for an Acknowledge from the master. If the Acknowledge occurs, the FM24C256 will transfer the next sequential byte. If the Acknowledge is not sent, the FM24C256 will end the read operation. For a write operation, the FM24C256 will accept 8 data bits from the master then send an acknowledge. All data transfer occurs MSB (most significant bit) first. Write Operation All writes begin with a device address, then a memory address. The bus master indicates a write operation by setting the LSB of the device address to a 0. After addressing, the bus master sends each byte of data to the memory and the memory generates an acknowledge condition. Any number of sequential bytes may be written. If the end of the address range is reached internally, the address counter will wrap from 7FFFh to 0000h. Unlike other nonvolatile memory technologies, there is essentially no write delay with FRAM. Since the read and write access times of the underlying memory are the same, the user experiences no delay on the bus. The entire memory cycle occurs in less time than a single bus clock. Therefore, any operation including a read or write can occur immediately following a write. Acknowledge polling, a technique used with EEPROMs to determine if a write has completed is unnecessary and will always return a ready condition. Internally, an actual memory write occurs after the 8th data bit is transferred. It will be complete before the Acknowledge is sent. Therefore, if the user desires to abort a write without altering the memory contents, this should be done using a Start or Stop condition prior to the 8th data bit. The FM24C256 uses no page buffering. The memory array can be write protected using the WP pin. Pulling the WP pin high will write-protect all addresses. The FM24C256 will not acknowledge data bytes that are written when WP is active. In addition, the address counter will not increment if writes are attempted to these addresses. Setting WP low will deactivate this feature. WP is internally pulled down. The state of WP should remain stable from the Start command until the address is complete. Figure 5 and 6 below illustrate both a single-byte and multiple-write.
Memory Operation
The FM24C256 is designed to operate in a manner very similar to other 2-wire interface memory products. The major differences result from the higher performance write capability of FRAM technology. These improvements result in some differences between the FM24C256 and a similar configuration EEPROM during writes. The complete operation for both writes and reads is explained below.
Rev 3.1 May 2005
Page 5 of 12
FM24C256
By Master Start Address & Data Stop
S
Slave Address
0A
X Address MSB
A
Address LSB
A
Data Byte
A
P
By FM24C256
Acknowledge
Figure 5. Single Byte Write
Start By Master Address & Data Stop
S
Slave Address
0A
X Address MSB
A
Address LSB
A
Data Byte
A
Data Byte
A
P
By FM24C256
Acknowledge
Figure 6. Multiple Byte Write Read Operation There are two types of read operations. They are current address read and selective address read. In a current address read, the FM24C256 uses the internal address latch to supply the address. In a selective read, the user performs a procedure to set the address to a specific value. Current Address & Sequential Read As mentioned above the FM24C256 uses an internal latch to supply the address for a read operation. A current address read uses the existing value in the address latch as a starting place for the read operation. The system reads from the address immediately following that of the last operation. To perform a current address read, the bus master supplies a device address with the LSB set to 1. This indicates that a read operation is requested. After receiving the complete device address, the FM24C256 will begin shifting out data from the current address on the next clock. The current address is the value held in the internal address latch. Beginning with the current address, the bus master can read any number of bytes. Thus, a sequential read is simply a current address read with multiple byte transfers. After each byte, the internal address counter will be incremented. Each time the bus master acknowledges a byte, this indicates that the FM24C256 should read out the next sequential byte. There are four ways to properly terminate a read operation. Failing to properly terminate the read will
Rev 3.1 May 2005
most likely create a bus contention as the FM24C256 attempts to read out additional data onto the bus. The four valid methods are as follows. 1. The bus master issues a no-acknowledge in the 9th clock cycle and a stop in the 10th clock cycle. This is illustrated in the diagrams below. This is preferred. The bus master issues a no-acknowledge in the 9th clock cycle and a start in the 10th. The bus master issues a stop in the 9th clock cycle. The bus master issues a start in the 9th clock cycle.
2. 3. 4.
If the internal address reaches 7FFFh, it will wrap around to 0000h on the next read cycle. Figures 7 and 8 show the proper operation for current address reads. Selective (Random) Read There is a simple technique that allows a user to select a random address location as the starting point for a read operation. This involves using the first three bytes of a write operation to set the internal address followed by subsequent read operations. To perform a selective read, the bus master sends out the device address with the lsb set to 0. This specifies a write operation. According to the write protocol, the bus master then sends the address bytes that are loaded into the internal address latch. After the FM24C256 acknowledges the address, the bus master issues a Start condition. This simultaneously aborts the write operation and allows the read command to be issued with the device address LSB set to a 1. The operation is now a current address read.
Page 6 of 12
FM24C256
By Master
Start
Address
No Acknowledge Stop
S
Slave Address
1A
Data Byte
1
P
By FM24C256
Acknowledge
Data
Figure 7. Current Address Read
By Master
Start
Address
Acknowledge
No Acknowledge Stop
S
Slave Address
1A
Data Byte
A
Data Byte
1P
By FM24C256
Acknowledge
Data
Figure 8. Sequential Read
Start By Master Address Start Address
No Acknowledge Stop
S
Slave Address
0A
Address MSB
A
Address LSB
A
S
Slave Address
1A
Data Byte
1P
By FM24C256 Acknowledge
Data
Figure 9. Selective (Random) Read
Endurance
A FRAM internally operates with a read and restore mechanism. Therefore, endurance cycles are applied for each read and write access. The FRAM architecture is based on an array of rows and columns. Rows (A14-A6) are subdivided into 8 segments (A5-A3). Each access causes an endurance cycle for a row segment. In the FM24C256, there are
8 bytes per segment. Endurance can be optimized by ensuring frequently accessed data is located in different segments. Regardless, FRAM read and write endurance is effectively unlimited at the 1MHz two-wire speed. Even at 30 accesses per second to the same segment, 10 years time will elapse before 10 billion endurance cycles occur.
Rev 3.1 May 2005
Page 7 of 12
FM24C256
Electrical Specifications
Absolute Maximum Ratings Symbol Description VDD Voltage on VDD with respect to VSS VIN Voltage on any signal pin with respect to VSS TSTG TLEAD VESD Storage Temperature Lead temperature (Soldering, 10 seconds) Electrostatic Discharge Voltage - Human Body Model (JEDEC Std JESD22-A114-B) - Machine Model (JEDEC Std JESD22-A115-A) Package Moisture Sensitivity Level Ratings -1.0V to +7.0V -1.0V to +7.0V and VIN < VDD+1.0V * -55°C to + 125°C 300° C 4kV 400V MSL-1
* Exception: The “VIN < VDD+1.0V” restriction does not apply to the SCL and SDA inputs. Stresses above those listed under Absolute Maximum Ratings may cause permanent damage to the device. This is a stress rating only, and the functional operation of the device at these or any other conditions above those listed in the operational section of this specification is not implied. Exposure to absolute maximum ratings conditions for extended periods may affect device reliability.
DC Operating Conditions (TA = -40° C to + 85° C, VDD = 4.5V to 5.5V unless otherwise specified) Symbol Parameter Min Typ Max Units Notes VDD Main Power Supply 4.5 5.0 5.5 V 1 IDD VDD Supply Current 200 @ SCL = 100 kHz µA 500 @ SCL = 400 kHz µA 1.2 @ SCL = 1 MHz mA ISB Standby Current 100 2 µA ILI Input Leakage Current 10 3 µA ILO Output Leakage Current 10 3 µA VIH Input High Voltage 0.7 VDD VDD + 0.5 V 4 VIL Input Low Voltage -0.3 0.3 VDD V 4 VOL Output Low Voltage 0.4 V @ IOL = 3 mA RIN Address Input Resistance (WP, A2-A0) 5 20 For VIN = VIL (max) KΩ 1 For VIN = VIH (min) MΩ VHYS Input Hysteresis 0.05 VDD V 4 Notes 1. SCL toggling between VDD-0.3V and VSS, other inputs VSS or VDD-0.3V 2. SCL = SDA = VDD. All inputs VSS or VDD. Stop command issued. 3. VIN or VOUT = VSS to VDD. Does not apply to WP, A2-A0 pins. 4. This parameter is characterized but not tested. 5. The input pull-down circuit is strong (20KΩ) when the input voltage is below VIL and weak (1MΩ) when the input voltage
is above VIH. This resistance is characterized and not tested.
Rev 3.1 May 2005
Page 8 of 12
FM24C256 AC Parameters (TA = -40° C to + 85° C, VDD = 4.5V to 5.5V, CL = 100 pF unless otherwise specified) Symbol Parameter Min Max Min Max Min Max fSCL SCL Clock Frequency 0 100 0 400 0 1000 tLOW Clock Low Period 4.7 1.3 0.6 tHIGH Clock High Period 4.0 0.6 0.4 tAA SCL Low to SDA Data Out Valid 3 0.9 0.55 tBUF tHD:STA tSU:STA tHD:DAT tSU:DAT tR tF tSU:STO tDH tSP Bus Free Before New Transmission Start Condition Hold Time Start Condition Setup for Repeated Start Data In Hold Data In Setup Input Rise Time Input Fall Time Stop Condition Setup Data Output Hold (from SCL @ VIL) Noise Suppression Time Constant on SCL, SDA 4.7 4.0 4.7 0 250 1000 300 4.0 0 50 0.6 0 50 1.3 0.6 0.6 0 100 300 300 0.25 0 50 0.5 0.25 0.25 0 100 300 100
Units kHz µs µs µs µs µs µs ns ns ns ns µs ns ns
Notes
1 1
Notes : All SCL specifications as well as start and stop conditions apply to both read and write operations. 1 This parameter is periodically sampled and not 100% tested.
Capacitance (TA = 25° C, f=1.0 MHz, VDD = 5V) Symbol Parameter CI/O Input/Output Capacitance (SDA) CIN Input Capacitance
Max 8 6
Units pF pF
Notes 1 1
Notes 1 This parameter is periodically sampled and not 100% tested.
AC Test Conditions Input Pulse Levels Input rise and fall times Input and output timing levels 0.1 VDD to 0.9 VDD 10 ns 0.5 VDD
Equivalent AC Load Circuit
5.5V
1700 Ω Output 100 pF
Rev 3.1 May 2005
Page 9 of 12
FM24C256 Diagram Notes All start and stop timing parameters apply to both read and write cycles. Clock specifications are identical for read and write cycles. Write timing parameters apply to slave address, word address, and write data bits. Functional relationships are illustrated in the relevant data sheet sections. These diagrams illustrate the timing parameters only. Read Bus Timing
tR tF t HIGH t LOW t SP t SP
`
SCL
t SU:SDA t BUF 1/fSCL t HD:DAT t SU:DAT t DH
SDA Start Stop Start
t AA
Acknowledge
Write Bus Timing
t HD:DAT
SCL
t SU:STO t HD:STA t SU:DAT t AA
SDA Start Stop Start Acknowledge
Data Retention (VDD = 4.5V to 5.5V, +85° C) Parameter Data Retention
Min 45
Units Years
Notes
Rev 3.1 May 2005
Page 10 of 12
FM24C256
Mechanical Drawing
8-pin EIAJ SOIC
Recommended PCB Footprint
9.30
5.28 ±0.10
8.00 ±0.25
2.15
5.00
Pin 1
1.27
0.65
5.23 ±0.10
1.78 2.00
0.19 0.25
1.27 0.36 0.50
0.05 0.25
0.10 mm
0°- 8°
0.51 0.76
All dimensions in millimeters.
EIAJ SOIC Package Marking Scheme
Legend: XXXXXX= part number LLLLLLL= lot code RIC=Ramtron Int’l Corp, YY=year, WW=work week XXXXXXX-G LLLLLLL RIC YYWW
FM24C256, “Green” EIAJ SOIC package, Year 2004, Work Week 50 FM24C256-G A40003S1 RIC 0450
RIC XXXXXXX-S
FM24C256, Standard EIAJ SOIC package (-SE) RIC FM24C256-S (Lot Code and Date Code on backside of package)
Rev 3.1 May 2005
Page 11 of 12
FM24C256
Revision History
Revision 1.0 1.1 1.2 1.3 3.0 Date 4/10/01 9/28/01 1/31/02 2/3/04 2/16/05 Summary Initial Release Changed Idd and Isb specifications. Changed test load to 1700 ohms to reflect 3mA VOL test condition. Updated package drawing and dimensions. Rewrote description of the internal memory architecture and endurance section. Added “part marking” note to Ordering Information (pg 1). Added “green” packaging option. Added ESD and package MSL ratings. Changed storage temperature. New rev. number and 1st page footer to comply with updated scheme. Changed Data Retention spec. Clarified Package Marking Scheme text and drawings.
3.1
5/5/05
Rev 3.1 May 2005
Page 12 of 12