LOR5.LV3E-R012-D

LOR5.LV3E-R012-D

  • 厂商:

    RCD

  • 封装:

  • 描述:

    LOR5.LV3E-R012-D - PRECISION LOW-OHM METAL PLATE RESISTORS - RCD COMPONENTS INC.

  • 详情介绍
  • 数据手册
  • 价格&库存
LOR5.LV3E-R012-D 数据手册
PRECISION LOW-OHM METAL PLATE RESISTORS RESISTORS CAPACITORS COILS DELAY LINES LV3 SERIES - MOLDED 3-WATT LOR SERIES - CERAMIC 3- & 5-WATT Term.W is Ideal for current sense applications RoHS compliant 0.0025Ω to .25Ω, 0.5% to 10% RoHS & 260°C compatible Low TC, high pulse capability Non-inductive metal element Available on RCD’s exclusive SWIFTTM delivery program! Choice of 2-terminal or 4-terminal designs RCD LV3 LOR LOR 4T OPTIONS Opt.18: .040” lead dia. on LOR3 (.040” is std on LOR5) Option 4T: 4 Terminal Option E: Low thermal emf design Non-std resistance values, custom marking, burn-in, etc. 1.25” Typ Series LOR rectangular shape and high thermal conductivity ceramic case efficiently transfers heat from the internal element resulting in excellent stability and overload capability. Series LV3 molded design offers improved uniformity for high-volume autoplacement applications. The resistance element of LOR and LV3 is non-inductive and constructed from near-zero TCR alloy minimizing thermal instability. Construction is flame retardent, solvent- and moisture-resistant. STANDARD RESISTANCE VALUES AND CODES (Non-standard values available, most popular values listed in bold) .0025Ω (R0025), .003Ω (R003), .005Ω (R005), .0068Ω(R0068), .0075Ω (R0075), .0082Ω (R0082), .01Ω (R010 if ≤1%,R01 if ≥2%), .012Ω(R012), .015Ω (R015), .02Ω (R020 if≤ 1%, R02 if≥ 2%), .022Ω (R022), .025Ω (R025), .03Ω (R030 if ≤1%, R03 if ≥ 2%), .033Ω (R033), .04Ω (R040≤1%, R04≥2%), .05Ω (R050≤1%, R05≥2%), .068Ω(R068), .07Ω (R070 if ≤1%, R07 if ≥ 2%), .075Ω (R075), .08Ω (R080 if≤1%, R08 ≥2%), .1Ω (R100 if≤1%, R10 ≥2%), .15Ω (R150 if ≤1%, R15 ≥2%), .2Ω (R200 if ≤1%, R20 ≥2%), .25Ω (R250 if ≤1%, R25 ≥2%). ← A → 2nd pair of leads applies to Opt. 4T only B B ↓ ↑d X X → ← Resis. Measurement Point (see Applic. Note #1) WATTAGE @25°C 3W 5W 3W C U R R EN T RATING1 25A 40A 25A C LOR is rectangular, LV is cylindrical RCD TYPE LOR3 LOR5 LV3 1 RESISTANCE RANGE (OHMS) .0025 to .25 .0025 to .25 .005 to 0.1 RESISTANCE MEASUREMENT POINT ±.062 [1.6] 1.310 [33.3] 1.670 [42.4] 1.310 [33.3] DIMENSIONS A ±.04 [1] .551 [14] .880 [22.35] .513 [13] B ±.032 [.8] .256 [6.5] .320 [8.13] .142 [3.6] d ±.002 [.05] .032 [.8] .040 [1] .032 [.8] 3 Specify 3 C2 ±.032 [.8] .075 [1.9] .100 [2.54] n/a Max. current is based on I= (P/R)1/2, not to exceed the value listed (increased levels avail). 2 Dim. C applies only to Opt.4T opt.18 for .040 [1mm] lead dia PERFORMANCE CHARACTERISTICS , POWER DERATING % Rated Power 100 75 50 25 0 25 50 75 100 125 150 175 200 225 250 275 Test Parameter Load Life Vibration Overload Temp. Coefficient Temp. Range Dielectric Strength Insulation Res. Terminal Strength Solderability Inductance Performance, Typ. 0.5% +.5mΩ 0.05% +.5mΩ 5 Sec, 5X rated W (NTE Current Rating) (per chart, 4wire conn. at body) -55° to +275°C 1000 VAC 10,000MΩ min dry 10 lb. min. per Mil-STD-202, m.208 5nH to 20nH typ Temperature °C TEMPERATURE COEFFICIENT (typ.) 400 300 250 200 150 100 50 0 0 LOR3, LV3 LOR5, LOR3-18 Opt.4T ppm/°C 10 20 Resistance (milli ohm) 30 40 50 60 70 80 90 APPLICATION NOTES: 1) 3W parts to be measured at 1.31” [33.3mm], 5W parts at 1.67” [42.4mm]. Also available per customer requirement. 2) 18AWG (0.040” dia) leads are standard on LOR5 and available on LOR3 (specify opt. 18). RCD recommends .040” leads, since the heavier gauge results in lower lead resistance, improved heat transfer, and lower in-circuit TCR (.032” leadwires have resistivity of ~1mΩ/in., 0.04” dia. have ~0.6mΩ/in). An extra inch of .032” leadwire in the circuit will increase the TC of a 10mΩ resistor by roughly 350ppm. Keep leadwires short for best TC stability. 3) To achieve utmost precision in current sense or shunt applications, RCD offers LOR3 & LOR5 in 4-terminal version, specify opt.4T (eliminates lead resistance when utilized in Kelvin configuration). Request App. note #R31 for performance comparison of 2- vs. 4-terminal. P/N DESIGNATION: RCD Type (LOR3, LOR5, or LV3) LOR3 - R05 - J B W Options: E, 4T, 18 (leave blank if standard) Resis. Code (see table above): 0.5% & 1%: 3 signif. digits & multiplier; R010=0.01Ω, R150=0.15Ω 2%-10%: use 2 signif.digits & multiplier; R01=.01Ω, R10=.1Ω, etc. Use extra digits as needed R005, R0025, R0075, R012, etc. Tolerance Code: D=0.5%, F=1%, G=2%, H=3%, J=5%, K=10% Packaging: B = bulk (std.),T = Tape & Reel (not avail. on option 4T) Termination: W= Lead-free, Q= Tin/Lead (leave blank if either is acceptable, in which case RCD will select based on lowest price and quickest delivery) RCD Components Inc, 520 E.Industrial Park Dr, Manchester, NH, USA 03109 rcdcomponents.com Tel: 603-669-0054 Fax: 603-669-5455 Email:sales@rcdcomponents.com FA049C Sale of this product is in accordance with GF-061. Specifications subject to change without notice. 55
LOR5.LV3E-R012-D
1. 物料型号 - RCD LV3系列:模塑3瓦特 - LOR系列:陶瓷3瓦特和5瓦特 - LOR 4T:四端子设计

2. 器件简介 - 这些电阻器符合RoHS标准,兼容260°C,非常适合电流感应应用,阻值范围从0.0025欧姆到0.25欧姆,精度从0.5%到10%。具有低温度系数、高脉冲能力和非感性金属元件等特点。

3. 引脚分配 - 2端或4端设计可选。对于LOR3,标准引线直径为0.040英寸;对于LOR5,标准引线直径也为0.040英寸。

4. 参数特性 - 标准电阻值和代码:列出了从0.0025欧姆到0.25欧姆的多种标准电阻值,以及对应的代码。 - 功率耗散:LOR3系列3瓦特、LOR5系列5瓦特、LV3系列3瓦特。 - 电流额定值:LOR3系列25安培、LOR5系列40安培、LV3系列25安培。 - 尺寸和电阻测量点:提供了详细的尺寸和测量公差。

5. 功能详解 - 性能特性包括负载寿命、振动、过载、温度系数、温度范围、耐压、绝缘电阻、端子强度和焊料性等。 - 温度系数图表和应用说明提供了详细的性能数据。

6. 应用信息 - 应用说明包括部件编号设计、引线选择、4端版本的优势等。例如,为了在电流感应或分流应用中实现极高的精度,RCD提供LOR3和LOR5的4端版本。

7. 封装信息 - 提供了LOR3、LOR5和LV3系列的详细尺寸和封装选项,包括标准封装和定制封装。
LOR5.LV3E-R012-D 价格&库存

很抱歉,暂时无法提供与“LOR5.LV3E-R012-D”相匹配的价格&库存,您可以联系我们找货

免费人工找货