Features
•
•
•
•
•
•
Regulated
Converter
Input Range: 80-264VAC or 80-305VAC
Temperature rang: -40 to +85°C with derating
Over voltage category OVC III
2MOPP medical certified B and BF compliant
Class B EMC filter built-in
4000/5000m (medical/ITE) operating altitude
AC/DC Converter
RACM60-K
Description
The multi-purpose, industrial + household + medical grade AC/DC converter series RACM60-K/OF
delivers 60 Watts of output power from -40°C to +55°C with natural air convection only, and up
to +85°C with derating or forced cooling. With a clear focus on extended thermal performance for
systems where space is limited, these 2” x 3” compact modules are designed to gain highest overall
efficiency levels over the full output load range from universal AC inputs. The RACM60-K/OF has
ANSI/AAMI/IEC 60601-1 medical safety and EN 60601-1-2 medical EMC certifications and offers
4kVAC/1 min isolation, 2MOPP and designed to meet B and BF requirements. It is additionally certified
to IEC/EN62368-1(CB Report) and IEC61558-1/-2-16 for industrial applications and IEC/EN60335-1
for household appliances. The robust built-in Class B EMC filter has sufficient margin to allow both
Installation Class II or Class I PELV with grounded output. A range of mechanical fixing options makes
the RACM60 suitable for many different mounting conditions: the standard chassis mount part mates
with Molex connectors and the /PCB option permits direct installation in printed circuit boards. Additionally, a 2” x 4” footprint for backwards-compatibility with legacy designs is available on request.
60 Watt
Open Frame
2“x3“ & 2“x4“
Enclosed 2“x4“
Selection Guide
Part
Number
RACM60-05SK (2, 3, 4)
RACM60-12SK (2, 3, 4)
RACM60-15SK (2, 3, 4)
RACM60-24SK (2, 3, 4)
RACM60-36SK (2, 3)
RACM60-48SK (2, 3, 4)
Input Voltage
Range
[VAC]
80-264/ 80-305
80-264/ 80-305
80-264/ 80-305
80-264/ 80-305
80-264
80-264/ 80-305
Output
Voltage
[VDC]
5
12
15
24
36
48
Output
Current
[mA]
8000
5000
4000
2500
1667
1250
Output
Power
[W]
40
60
60
60
60
60
Efficiency
typ. (1)
[%]
89
90
90
90
90
90
Notes:
Note1: Efficiency is tested at nominal input and full load at +25°C ambient
Model Numbering
RACM60- __ SK /277/__/__-__
Packaging options (4)
Mechanical variations (3)
Case style (3)
Input voltage option (2)
/OF
/277/OF
/OF/PCB
/OF/2x4
/ENC/2x4
RACM60-05SK
x
x
x
on request
on request
RACM60-12SK
x
x
x
x
x
RACM60-15SK
x
x
on request
on request
on request
RACM60-24SK
x
x
x
x
x
RACM60-36SK
x
on request
on request
on request
on request
RACM60-48SK
x
x
on request
on request
on request
x = standard portfolio / on request = MOQ may apply on project base / N/A= not available
www.recom-power.com
REV.: 4/2023
O
U S E HO
LD
Model Matrix (4)
Model
E314885
CERTIFIED
pp
es
EN-60335-1
a
Notes:
Note2: Add suffix “/277/OF” for wider input voltage range (80-305VAC)
Without suffix= standard input range (80-264VAC), check “Model Matrix (4)”
For more information, refer to “Input Voltage Range (5,6)”
Note3: “/OF” = standard 2”x3” open frame version with standard connectors
“/OF/PCB = 2”x3” open frame with PCB mounting pins
“/OF/2x4” = 2”x4” open frame version with standard connectors
“/ENC/2x4” = 2”x4” version with metal enclosure and standard connectors (coming soon)
Note4: for packaging details refer to last page “PACKAGING INFORMATION”
H
Nom. output power
Nom. output voltage
Single
lianc
2MOPP
250VAC
IEC/EN62368-1 certified
UL1310 pending, NEC Class 2 (12/24SK/OF)
ANSI/AAMI ES60601-1 Ed. 3.1 certified
CSA/CAN-C22.2 No. 60601-1:14 certified
IEC/EN60335-1 certified
IEC/EN61558-1 certified
IEC/EN61558-2-16 certified
EN60601-1-2 compliant
EN55032 compliant
EN55035 compliant
CB Report
PA-1
RACM60-K
Series
AC/DC Converter
Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated)
BASIC CHARACTERISTICS
Parameter
Condition
Min.
Typ.
Internal Input Filter
Max.
Pi Type
Nominal Input Voltage
50/60Hz
standard version
“/277” version
100VAC
240VAC
277VAC
standard version
47-63Hz
DC
80VAC
120VDC
264VAC
370VDC
“/277” version
47-63Hz
DC
80VAC
120VDC
305VAC
430VDC
1400mA
600mA
500mA
30A
60A
70A
Input Voltage Range (5,6)
115VAC
230VAC
277VAC
Input Current
Inrush Current
cold start
ErP Standby Mode Conformity
(Output Load Capability)
115/230/277VAC
115VAC
230VAC
277VAC
0.5W
Input Power:
1.0W
0.3W
0.7W
No load Power Consumption
230VAC
277VAC
100mW
120mW
Input Frequency Range
AC Input
47Hz
115VAC
230VAC
277VAC
0%
0.6
0.5
0.45
Minimum Load
Power Factor
Start-up Time
63Hz
150ms
Rise Time
100ms
Hold-up Time
Internal Operating Frequency
Output Ripple and Noise
12ms
50ms
70ms
115VAC
230VAC
277VAC
100% load at nominal Vin
5Vout
20MHz BW
others
(7)
100kHz
200mVp-p
1% of Vout
Notes:
Note5: The products were submitted for safety files at AC-Input operation (90-264VAC)
Note6: Output power derating for Line-input of less than 90VAC (derate linearly from 100% at 90VAC to 80% at 80VAC)
Note7: Measurements are made with a 0.1µF MLCC & 10µF E-cap in parallel across output. (low ESR)
Efficiency vs. Load
100
90
Efficiency [%]
80
70
60
50
40
30
115VAC
230VAC
277VAC
20
10
0
0
10
20
30
40
50
60
70
80
90
100
Output Load [%]
www.recom-power.com
REV.: 4/2023
PA-2
RACM60-K
Series
AC/DC Converter
Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated)
REGULATIONS
Parameter
Condition
Output Accuracy
Line Regulation
standard version
100% load
±2.0% typ.
“/277” version
5Vout
others
±3.0% typ.
±1.0% typ.
standard version
low line to high line
±0.05% typ.
5Vout
others
5VDC
12VDC, 15VDC
24VDC, 36VDC, 48VDC
5VDC
12VDC, 15VDC
24VDC, 36VDC, 48VDC
±0.5% typ.
±0.05% typ.
±1.5% typ.
±0.5% typ.
±0.1% typ.
±3.0% typ.
±0.8% typ.
±0.2% typ.
“/277” version
standard version
Load Regulation
Value
10% to 100% load
(8)
“/277” version
10% to 100% load
Transient Response
25% load step change
3.0% max.
recovery time
500µs max.
Notes:
Note8: Operation below 10% load will not harm the converter, but specifications may not be met
Deviation vs. Load
2
1.5
Deviation [%]
1.0
0.5
0
-0.5
-1.0
-1.5
-2
0
10
20
30
40
50
60
70
80
90
100
Output Load [%]
PROTECTIONS
Parameter
Input Fuse
Type
internal
Value
T3.15A, slow blow type
Short Circuit Protection (SCP)
hiccup, auto recovery
Over Voltage Protection (OVP)
105 - 120%, auto recovery
Output Reverse Voltage Protection
107 - 145%, auto recovery
Over Voltage Category (OVC) (9)
according to 62368-1, 61558-2-16 & 60335-1
according to 61558-2-16
Over Current Protection (OCP)
Thermal Shutdown
OVC II
OVC III (up to 2000m)
130% - 180%, hiccup mode
TC point IC 101
+130°C, restart after cool down
Notes:
Note9: RACM60-xxK/277/OF models were submitted to safety agency for OVC III rating.
continued on next page
www.recom-power.com
REV.: 4/2023
PA-3
RACM60-K
Series
AC/DC Converter
Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated)
Parameter
Type
Value
Class of Equipment
Class II
1 minute
Isolation Voltage (safety certified) (10)
I/P to O/P; according to 61558-2-16, 60601-1
4.2kVAC
Isolation Resistance
I/P to O/P, VISO= 500VDC
1GΩ min.
Isolation Capacitance
I/P to O/P, 100kHz/0.1V
100pF max.
Insulation Grade
reinforced
Means of Protection
319VAC working voltage
2MOPP
Notes:
Note10: For repeat Hi-Pot testing, reduce the time and/or the test voltage
ENVIRONMENTAL
Parameter
Condition
Operating Temperature Range
@ natural convection 0.1m/s
Value
refer to graphs below
-40°C to +85°C
Temperature Coefficient
±0.02%/K
according to 62368-1, 61558-2-16 & 60335-1
Operating Altitude (11)
5000m
according to 60601-1
Operating Humidity
4000m
non-condensing
95% max.
Pollution Degree
PD2
Vibration
according to MIL-STD-202G
MTBF
10-500Hz, 2G 10min./1cycle, period 60min. along x,y,z axes
according to MIL-HDBK-217F, G.B.
+25°C
+40°C
>900 x 103 hours
>726 x 103 hours
nom. Vin= 230VAC
+40°C
>42 x 103 hours
Design Lifetime
Notes:
Note11: Recognized by safety agency for safe operation up to 4000/5000m. High altitude operation may impact the performance and lifetime
Please contact RECOM tech support for advice
Derating Graph non-/277/OF Versions
(@ Chamber and natural convection 0.1m/s)
Output power derating for line-input of less than 90VAC (derate linearly from 100% at 90VAC to 80% at 80VAC)
others
60
60
55
55
50
50
45
45
Output Power [W]
Output Power [W]
RACM60-05SK
40
35
30
25
18
20
15
12
10
5
40
35
30
25
18 20
15
10
115-240VAC nom.
100VAC nom.
0
-40 -30 -20 -10 0
115-240VAC nom.
100VAC nom.
5
0
-40 -30 -20 -10 0
10 20 30 40 50 60 70 80 90
85
Ambient Temperature [°C]
10 20 30 40 50 60 70 80 90
45 55
75 85
Ambient Temperature [°C]
continued on next page
www.recom-power.com
REV.: 4/2023
PA-4
RACM60-K
Series
AC/DC Converter
Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated)
Derating Graph “/277/OF” Version
(@ Chamber and natural convection 0.1m/s)
Output power derating for Line-input of less than 90VAC (derate linearly from 100% at 90VAC to 80% at 80VAC)
RACM60-05SK/277/OF
other “/277/OF” Versions
60
60
55
54
50
40
36
35
30
25
5
40
35
30
25
21
1820
15
20
14 15
13 10
50
45
Output Power [W]
Output Power [W]
45
55
10
115-277VAC nom.
100VAC nom.
0
-40 -30 -20 -10 0
5
115-277VAC nom.
100VAC nom.
0
-40 -30 -20 -10 0
10 20 30 40 50 60 70 80 90
85
Ambient Temperature [°C]
10 20 30 40 50 60 70 80 90
85
Ambient Temperature [°C]
SAFETY AND CERTIFICATIONS
Certificate Type (Safety)
Report Number
Medical electrical equipment Part 1: General requirements for basic safety
and essential performance
E511305-D1000-1/A1/C0-UL
Standard
CAN/CSA-C22.2 No. 60601-1:14, 3rd Ed.
ANSI/AAMI ES60601-1:2005 + A2:2010/R2012
Audio/Video, information and communication technology equipment - Safety
requirements (CB Scheme)
CN21PMDW-001
IEC62368-1:2014 2nd Edition
Audio/Video, information and communication technology equipment - Safety
requirements (LVD)
50355749 001
EN62368-1:2014 + A11:2017
Household and similar electrical appliances – Safety – Part 1: General
requirements (LVD)
4384104.50
pending
Standard for Class 2 Power Units (TÜV)
(RACM60-12SK/OF, RACM60-24SK/OF only)
Safety of power transformers, power supplies, reactors & similar products for
supply voltages up to 1100 V (CB Scheme)
Safety of power transformers, power supplies, reactors & similar products for
supply voltages up to 1100 V Part 2: Particular requirements (CB Scheme)
Safety of power transformers, power supplies, reactors & similar products for
supply voltages up to 1100V
Safety of power transformers, power supplies, reactors & similar products for
supply voltages up to 1100 V Part 2: Particular requirements
Safety of power transformers, power supplies, reactors and similar products
for supply voltages up to 1100 V (CB Scheme)
Safety of power transformers, power supplies, reactors and similar products
for supply voltages up to 1100 V Part 2: Particular requirements (CB Scheme)
Safety of power transformers, power supplies, reactors and similar products
for supply voltages up to 1100 V
Safety of power transformers, power supplies, reactors and similar products
for supply voltages up to 1100 V Part 2: Particular requirements
50355750 001
(except /277/OF & /ENC/2x4)
50355751 001
(except /277/OF & /ENC/2x4)
085-210569701-000
(OVCIII)
64.210.21.05697.01
(OVCIII)
IEC60335-1:2010 5th Edition + A2:2016
EN60335-1:2012 + A15:2021
UL1310:2018 + R:2020-06
IEC61558-1:2005 2nd Edition + A1:2009
IEC61558-2-16:2009 1st Edition + A1:2013
EN61558-1:2005 + A1:2009
EN61558-2-16:2009 + A1:2013
IEC61558-1:2017
IEC61558-2-16:2009 1st Edition + A1:2013
EN IEC 61558-1:2019
EN61558-2-16:2009 + A1:2013
continued on next page
www.recom-power.com
REV.: 4/2023
PA-5
RACM60-K
Series
AC/DC Converter
Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated)
EMC Compliance (EN60601-1-2)
Condition
Standard / Criterion
Medical electrical equipment - Part 1-2: General requirements for basic safety
and essential performance - Collateral standard: Electromagnetic compatibility Requirements and tests
LCS220321054BE
EN60601-1-2:2015+A1:2021
Class B, Group 1
ESD Electrostatic discharge immunity test
Air: ±2, 4, 8, 15kV
Contact: ±2, 4, 8kV
EN61000-4-2:2009, Criteria B
9V/m (704-787MHz)
9V/m (5100-5800MHz)
10V/m (80-2700MHz)
27V/m (380-390MHz)
28V/m (430-470MHz)
28V/m (800-960MHz)
28V/m (1700-1990MHz)
28V/m (2400-2570MHz)
Radiated, radio-frequency, electromagnetic field immunity test
Fast Transient and Burst Immunity
EN61000-4-3:2006+A2:2010, Criteria A
AC Port: L-N 2kV
EN61000-4-4:2012, Criteria B
L-N: 1kV
L (N)-PE: 2kV
EN61000-4-5:2014, Criteria B
AC Port:
3Vrms: (0.15-80MHz)
6Vrms: (ISM and amateur radio
bands according to table 9)
EN61000-4-6:2014, Criteria A
Power Magnetic Field Immunity
30A/m
EN61000-4-8:2010, Criteria A
Voltage Dips and Interruptions
Dips: 100% (0.5P 1.0P)
30%
Interruptions: 100%
EN61000-4-11:2004, Criteria B
Surge Immunity
Immunity to conducted disturbances, induced by radio-frequency fields
Limits of Voltage Fluctuations & Flicker
LCS220321054BE
EMC Compliance (EN55032)
Condition
Electromagnetic compatibility of multimedia equipment - Emission requirements
Electromagnetic compatibility of multimedia equipment - Immunity requirements
LCS220321053BE
Air: ±2, 4, 8kV
Contact: ±2, 4kV
ESD Electrostatic discharge immunity test
Radiated, radio-frequency, electromagnetic field immunity test
Fast Transient and Burst Immunity
Surge Immunity
Immunity to conducted disturbances, induced by radio-frequency fields
EN55035:2017+A11:2020
EN61000-4-2:2009, Criteria B
EN61000-4-3:2006+A2:2010, Criteria A
AC Port: L-N 1kV
EN61000-4-4:2004+A1:2010, Criteria B
L-N: 1kV
L (N)-PE: 2kV
EN61000-4-5:2014 + A1:2017, Criteria B
AC Port:
3Vrms (0.15-10MHz)
3-1Vrms (10-30MHz)
1Vrms (30-80MHz)
EN61000-4-6:2014+A1:2015, Criteria A
1A/m
Dips: 100%
30%
Interruptions:100%
LCS220321053BE
Limits of Voltage Fluctuations & Flicker
Standard / Criterion
EN55032:2015+A1:2020, Class B
3 V/m (80-5000MHz)
Power Magnetic Field Immunity
Voltage Dips and Interruptions
EN61000-3-3:2013
EMC Compliance (EN61204-3)
Condition
EN61000-4-8:2010, Criteria A
EN61000-4-11:2004+A1:2017, Criteria B
EN61000-4-11:2004+A1:2017, Criteria C
EN61000-4-11:2004+A1:2017, Criteria C
EN61000-3-3:2013
Standard / Criterion
Low voltage power supplies, d.c. output Part 3: Electromagnetic compatibility
(EMC)
LCS220321055BE
EN/IEC61204-3:2018, Class B
ESD Electrostatic discharge immunity test
Air: ±2, 4, 8kV
Contact: ±2, 4kV
EN61000-4-2:2009, Criteria B
continued on next page
www.recom-power.com
REV.: 4/2023
PA-6
RACM60-K
Series
AC/DC Converter
Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated)
EMC Compliance (EN61204-3)
Condition
10V/m (80-1000MHz)
3V/m (1400-2000MHz)
1V/m (2000-2700MHz)
Radiated, radio-frequency, electromagnetic field immunity test
Fast Transient and Burst Immunity
AC Port: L-N 2kV
EN61000-4-4:2012, Criteria B
EN61000-4-5:2014 + A1:2017, Criteria B
AC Port:
10Vrms (0.15-80MHz)
EN61000-4-6:2014+A1:2015, Criteria A
Power Magnetic Field Immunity
30A/m
Voltage Dips and Interruptions
Dips: 100% (0.5P, 1.0P)
30% or 20%
Interruptions:100%
Limits of Voltage Fluctuations & Flicker
EN61000-4-3:2006+A2:2010, Criteria A
L-N: 1kV
L (N)-PE: 2kV
Surge Immunity
Immunity to conducted disturbances, induced by radio-frequency fields
Standard / Criterion
LCS220321055BE
EN61000-4-8:2010, Criteria A
EN61000-4-11:2004 +A1:2017, Criteria B
EN61000-4-11:2004 +A1:2017, Criteria B
EN61000-4-11:2004 +A1:2017, Criteria C
EN61000-3-3:2013+A2:2021
Limitations on the amount of electromagnetic interference allowed from digital and
electronic devices
WTD22D04060199E
FCC 47 CFR Part 15:2020 Subpart B
Limitations on the amount of electromagnetic interference allowed from digital and
electronic devices, industrial, scientific, and medical equipment
WTD22D04060215E
FCC 47 CFR Part 18:2020
DIMENSION AND PHYSICAL CHARACTERISTICS
Parameter
Type
Value
Material
PCB
FR4 (UL94-V0)
Dimension (LxWxH)
Weight
“/OF” and type
78.4 x 53.0 x 31.5mm
“/277/OF” type
76.2 x 50.8 x 32.0mm
“/OF/PCB” type
78.4 x 53.0 x 35.4mm
“/OF/2x4” type
101.6 x 53.0 x 31.5mm
“/ENC/2x4” type
118.3 x 62.7 x 38.7mm
“/OF”; “/277/OF” and “/OF/PCB” types
111g typ.
“/OF/2x4” type
120g typ.
“/ENC/2x4” type
167g typ.
continued on next page
www.recom-power.com
REV.: 4/2023
PA-7
23.27
RACM60-K
Series
AC/DC Converter
Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated)
2x 3.96
1
Dimension Drawing “/OF” (mm)
20.57
Front View
6x 1.14
1.6
31.5 MAX
1.6
68.3
5.2
78.4
CON2
FC 34.9
4x Ø3.2
FC 34.9
IC101
FC 22.2
Bottom View
FC 34.9
FC 22.2
53.0
4x Ø3.2
Connector Information
#
Function
Terminal
AC Input (CON1)
1
VAC in (N)
3 Pins (Pin2 removed)
3
VAC in (L)
with 3.96mm pitch
FC 22.253.0
IC101
78.4
FC 22.2
2.4
FC 34.9
CON2
DC Output Side View
26.9
68.3
5.0
1.6
3x 3.96
5.2
26.9
6x 1.14
7
6
5
4
CON1
2.4
5.0
AC Input Side View
3x 3.96
3
CON2
1
CON2
CON1
3
Top View
CON1
1
7
6
5
4
31.5 MAX
2x 3.96
2x 3.96
23.27
23.27
20.57
5.0
4x Ø3.2
Compatible Connector
Housing
Molex 41695 Series or equivalent
Crimp Terminal
Molex 2478 Series or equivalent
4,5
6,7
DC Output (CON2)
-VDC out
4 Pins
+VDC out
with 3.96mm pitch
FC = fixing centers
General tolerances according to ISO 2768-m
(table for reference only)
Dimension range
0.5 - 6 mm
6 - 30 mm
30 - 120 mm
120 - 400 mm
Tolerances
±0.1 mm
±0.2 mm
±0.3 mm
±0.5 mm
continued on next page
www.recom-power.com
REV.: 4/2023
PA-8
3
3.2
21.54
Series
2x 3.96
Dimension Drawing “277/OF” (mm)
3.2
3.2
1
CON1
4.1
3
32.0 max.
Top View
AC Input Side View
23.19
23.19
3
7
6 7
5 6
4 5
4
3.2
3x 3.96 9.32
3x 3.96 9.32
3.2
3.2
21.54
21.54
2x 3.96
2x 3.96
14.94
14.94
50.8
50.8
1
3
14.94
Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated)
76.2
76.2
3.2
3.2
2.94
2.94
4x Ø3.2
DC Output Side View
FC 3.2
70.06
70.06
Front View
1.6
1.6
CON2
CON2
FC 3.2
4.1
4.1
4x Ø3.2
4x Ø3.2
2x FC 34.9
2x FC 34.9
FC 3.2
FC 3.2
2x FC 22.2
2x FC 22.2
FC 3.2
FC 3.2
Bottom View
FC 3.2
FC 3.2
FC 3.2
FC 3.2
Compatible Connector
Housing
Molex 41695 Series or equivalent
Crimp Terminal
Molex 2478 Series or equivalent
Connector Information
#
Function
Terminal
AC Input (CON1)
1
VAC in (N)
3 Pins (Pin2 removed)
3
VAC in (L)
with 3.96mm pitch
4,5
6,7
DC Output (CON2)
-VDC out
4 Pins
+VDC out
with 3.96mm pitch
FC = fixing centers
General tolerances according to ISO 2768-m
(table for reference only)
Dimension range
0.5 - 6 mm
6 - 30 mm
30 - 120 mm
120 - 400 mm
Tolerances
±0.1 mm
±0.2 mm
±0.3 mm
±0.5 mm
continued on next page
www.recom-power.com
REV.: 4/2023
1
50.8
AC/DC Converter
32.0 max.
32.0 max.
1
RACM60-K
PA-9
RACM60-K
Series
AC/DC Converter
Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated)
Dimension Drawing “/OF/2x4” (mm)
CON2
3
2x 3.96
Top View
CON1
1
5.6
6x 1.14
7
6
5
4
3x 3.96
23.27
20.57
9.5
CON3
5.8
90.23
26.9
101.6
20.57
FC 47.6
Tolerances
±0.1 mm
±0.2 mm
±0.3 mm
±0.5 mm
2.4
Dimension range
0.5 - 6 mm
6 - 30 mm
30 - 120 mm
120 - 400 mm
FC 47.6
REV.: 4/2023
22.2
26.9
31.5 MAX
continued on next page
www.recom-power.com
3x 3.96
53.0
FC 22.2
CON1
(table for reference only)
1.6
26.9
General tolerances according to ISO 2768-m
101.6
FC 47.6
4
Compatible Connector
Housing
Molex 41695 Series or equivalent
6x 1.14Crimp5.8
Terminal
Molex 2478 Series or equivalent
CON2
2.4
101.6
IC101
90.23
6
FC = fixing centers
5 refer to “/OF” drawing)
Compatible connector please
CON2
9.5
DC Output Side View
AC Input Side View
CON1
3
5.6
31.5 MAX
90.23
5.8
Connector Information
# Function
Terminal
AC Input (CON1)
1 VAC in (N) 3 Pins (Pin2 removed)
3 VAC in (L)
with 3.96mm pitch
DC Output (CON2)
4,5 -VDC out
4 Pins
6,7 +VDC out with 3.96mm pitch
FE (CON3)
functional
8
fast on
7
earth
PA-10
IC101
2.2
6x 1.14
1
Bottom View
FC 22.2
4x Ø4.0
FC 47.6
CON3
IC101
2x 3.96
7
6
5
4
3x 3.96
CON2
20.57
23.27
FC 47.6
CON2
2.4
1.6
31.5 MAX
Front View
23.25
RACM60-K
Series
AC/DC Converter
2x 3.96
Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated)
Dimension Drawing “/OF/PCB” (mm)
5.0
5.0
CON1
5.2
DC Output Side View
CON2
6.3
1.6
35.4 MAX
Front View
1.6
7
6
5
4
68.26
6x 1.14
4.1
CON2
CON1
3
Top View
26.8
2x 3.96
1
3x 3.96
23.25
20.54
AC Input Side View
78.4
FC 34.9
4x Ø3.2
Pin-header Information
#
Function
Terminal
AC Input (CON1)
1
VAC in (N)
3 Pins (Pin2 removed)
3
VAC in (L)
with 3.96mm pitch
FC 34.9
4x Ø3.2
Bottom View
53.0
1
FC 22.2
3
4
5
6
7
FC 22.2
IC101
4,5
6,7
DC Output (CON2)
-VDC out
4 Pins
+VDC out
with 3.96mm pitch
Color of the connector may alternatively appear
black or white related to th batch of production
General tolerances according to ISO 2768-m
(table for reference only)
Dimension range
0.5 - 6 mm
6 - 30 mm
30 - 120 mm
120 - 400 mm
www.recom-power.com
REV.: 4/2023
Tolerances
±0.1 mm
±0.2 mm
±0.3 mm
±0.5 mm
PA-11
RACM60-K
Series
AC/DC Converter
Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated)
Dimension Drawing “/ENC” (mm)
62.7
28.1
25.4
118.3
13.5
1.00
35.2
Front View
9.1
FC 22.25
3.7
.4
8x Ø3
110.9
General tolerances according to ISO 2768-m
(table for reference only)
Dimension range
0.5 - 6 mm
6 - 30 mm
30 - 120 mm
120 - 400 mm
Tolerances
±0.1 mm
±0.2 mm
±0.3 mm
±0.5 mm
44.5
44.5
Bottom View
DC Output Side View
FC 22.25
5.8
7.5
6.6
7.5
AC Input Side View
62.7
38.7
14.6
62.7
3x 3.96
7.92
Top View
Connector Information
# Function
Terminal
AC Input (CON1)
1 VAC in (N) 3 Pins (Pin2 removed)
3 VAC in (L)
with 3.96mm pitch
DC Output (CON2)
4,5 -VDC out
4 Pins
6,7 +VDC out
with 3.96mm pitch
www.recom-power.com
REV.: 4/2023
44.5
FC = fixing centers
PA-12
Series
DC
AC/DC
Converter DC
AC
Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated)
APPLICATION AND INSTALLATION
Mounting
horizontal (standard)
vertical
DC
AC
DC
AC
airflow
airflow
If module is mounted vertical or upside-down with natural convection cooling,
the power must be derated ≥ 10%.vertical
DC
upside-down
AC
airflow
airflow
AC
DC
AC
upside-down
airflow
Blockdiagram (“/OF”, “/277/OF” and “/OF/PCB”)
airflow
DC
L
N
T3.5A
AC
Input
Filter
Active
Rectification
Rectifier
+V
Output
Filter
-V
upside-down
Feedback
Snubber
airflow
DC
Flyback Controller
Isolation
flow
RACM60-K
vertical
horizontal (standard)
Rectification
Controller+
Feedback
AC
continued on next page
www.recom-power.com
REV.: 4/2023
PA-13
RACM60-K
Series
AC/DC Converter
Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated)
APPLICATION AND INSTALLATION
Blockdiagram (“/OF/2x4”)
T3.5A
L
T3.5A
N
Input
Filter
FE
Active
Rectification
Rectifier
+V
-V
Feedback
Isolation
Snubber
Flyback Controller
Output
Filter
Rectification
Controller+
Feedback
Blockdiagram (“/ENC/2x4”)
N
PE
T3.5A
T3.5A
Input
Filter
Rectifier
Output
Filter
+V
-V
Feedback
Snubber
Flyback Controller
www.recom-power.com
Active
Rectification
Isolation
L
REV.: 4/2023
Rectification
Controller+
Feedback
PA-14
RACM60-K
Series
AC/DC Converter
Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated)
PACKAGING INFORMATION
Parameter
Type
“/OF” type
“/OF/2x4” type
“/277/OF-T” type
“/OF/PCB-T” type
“/ENC/2x4” type
Packaging Dimension (LxWxH)
65.0 x 55.0 x 95.0mm
65.0 x 50.0 x 110.0mm
215.0 x 365.0 x 62.0mm
365.0 x 210.0 x 56.0mm
405.0 x 360.0 x 85.0mm
cardboard box (single pack)
single tray (carton)
“/OF-CTN” type
Package Unit
Value
tray in carton (project pack)
375.0 x 220.0 x 245.0mm
“/OF” type and “/OF/2x4” type
1pcs
“/277/OF-T” and “/OF/PCB-T” type
12pcs
“/ENC/2x4” type
18pcs
“/OF-CTN” type, MOQ= 1152pcs
48pcs
Storage Temperature Range
-40°C to +90°C
Storage Humidity
non-condensing
95% max.
ORDERING EXAMPLE
RACM60-05SK/OF
Output
Voltage
5Vout
RACM60-24SK/OF/PCB-T
24Vout
80-264VAC
2” x 3”
open frame
PCB mounting pins
12pcs
tray
RACM60-12SK/OF/2x4
12Vout
80-264VAC
2” x 4”
open frame
standard connector
1pc
cardboard box
RACM60-05SK/277/OF-T
5Vout
80-305VAC
2” x 3”
open frame
standard connector
12pcs
tray
RACM60-24SK/ENC/2x4
24Vout
80-264VAC
2” x 4”
enclosed
standard connector
18pcs
tray
RACM60-12SK/OF-CTN
12Vout
80-264VAC
2” x 4”
open frame
standard connector
48pcs (MOQ= 1152pcs)
carton
Model-number
Input Range
Size
Type
Connection
Quantity
Packaging Type
80-264VAC
2” x 3”
open frame
standard connector
1pc
cardboard box
The product information and specifications may be subject to changes even without prior written notice.The product has been designed for various applications; its suitability lies in the responsibility of each customer. The products
are not authorized for use in safety-critical applications without RECOM’s explicit written consent. A safety-critical application is an application where a failure may reasonably be expected to endanger or cause loss of life, inflict
bodily harm or damage property. The applicant shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the unauthorized use of RECOM
products in such safety-critical applications.
www.recom-power.com
REV.: 4/2023
PA-15