Features
Unregulated
Converters
• Qualified with 65kV/µs @ Vcommon mode =1KV
• IEC/EN61010 for test, measurement and lab use
• IEC/EN60601 for medical applications
• Reinforced isolation 6.4kVDC or 8kVDC
• Optional continuous short circuit protection
• Very low isolation capacitance
• /X2 Option for >9mm input/output clearance
DC/DC Converter
RxxP2xx/R
2 Watt
3
SIP 7
Single and Dual
Output
Description
YEA R
The RxxP2xx/R Series of DC/DC Converters are certified to IEC/EN/UL/CSA-60950. This makes them
ideal for safety applications where approved or reinforced isolation is required. These versions are
also EN61010-1 certified for lab equipment. The /X2 version has an input/output clearance of more
than 9mm.
w
600
72 - 78
3300
5, 12, 15, 24
5
400
79 - 84
1200
RxxP209S/R (3,4,5)
5, 12, 15, 24
9
222
80 - 87
1200
5, 12, 15, 24
12
167
80 - 87
680
RxxP215S/R (3,4,5)
5, 12, 15, 24
15
133
80 - 88
680
(3,4,5)
5, 12, 15, 24
±3.3
±300
73 - 80
±1500
RxxP205D/R (3,4,5)
5, 12, 15, 24
±5
±200
79 - 85
±470
RxxP205S/R
RxxP212S/R
(3,4,5)
RxxP23.3D/R
5, 12, 15, 24
±9
±111
80 - 87
±470
RxxP212D/R (3,4,5)
5, 12, 15, 24
±12
±85
80 - 87
±330
5, 12, 15, 24
±15
±66
80- 87
±330
RxxP209D/R
(3,4,5)
M
CONVER
T
10 from 10
PL
U
D
IA N
T PRO
M
CONVER
T
S
M
O
REACH
compliant
CO
CO
Notes:
Note1: Efficiency is tested at nominal input and full load at +25°C ambient
Note2: Max. Capacitive Load is defined as the capacitive load that will allow start up
in under 1 second without damage to the converter
C
R
S
RoHS 2 +
compliant
E
O
R
C
E
RE
RxxP215D/R
(3,4,5)
M
TS
3.3
C
5, 12, 15, 24
(3,4,5)
TS
RxxP23.3S/R (3,4,5)
C
nom. Input
Output
Output
Efficiency max. Capacitive
Voltage Voltage Current typ. (1) Load (2)
[VDC] [VDC] [mA] [%]
[µF]
RE
Selection Guide
Part
Number
y
arrant
PL
U
D
IA N
T PRO
E314885
Model Numbering
UL/CSA60950-1 certified
IEC/EN60950-1 certified
UL/ES/CSA60601-1 certified
IEC/EN60601-1 certified
IEC/EN61010-1 certified
CB report
R__P2 __ _/P/X2/R
Input Voltage
“Reinforced Isolation (3)”
Output Power
“Pinout (4)”
Output Voltage
“Protection (5)”
Single or Dual
Notes:
Note3: add suffix „/R6.4“ for 6.4kVDC/1second isolation or „/R8“ for 8kVDC/1second isolation
Note4: add suffix „/X2“ for single output with alternative pinout
Note5: add suffix „/P“ for continous short circuit protection
Ordering Examples:
R05P23.3S/R8/P = 5V Input, 3.3V Output, Single Output, 8kVDC/1s isolation, Continous Short Circuit Protection
R24P205S/R6.4/P/X2 = 24V Input, 5V Output, Single Output, 6.4kVDC/1s isolation, Continous SCP, Alternative Pinout
R12P205D/R8/X2 = ±12V Input, ±5V Output, Dual Output, 8kVDC/1s isolation, Alternative Pinout
REF
DESIGN
available
www.recom-power.com/eval-ref-boards
www.recom-power.com
REV.: 6/2020
dv/dt
ADVISORY
REPORT
AVAILABLE
www.recom-power.com/bier
ECO-1
RxxP2xxS_D/R
DC/DC Converter
Series
Specifications (measured at Ta= 25°C, nominal input voltage, full load)
BASIC CHARACTERISTICS
Parameter
Condition
Min.
Typ.
Input Voltage Range
Max.
±10%
Minimum Load
Internal Operating Frequency
Output Ripple and Noise
0%
20kHz
(6)
50kHz
85kHz
20MHz BW
200mVp-p
Notes:
Note6: Measurements are made with a 0.1µF MLCC across output (low ESR)
Efficiency vs. Load
RxxP205S/R6.4 and
RxxP205S/R8
100
90
90
80
80
70
70
Efficiency [%]
Efficiency [%]
100
60
50
40
30
60
50
40
30
5Vin
12Vin
24Vin
20
10
0
RxxP205D/R6.4 and
RxxP205D/R8
0
10
20
30
40
50
60
70
80
20
5Vin
12Vin
24Vin
10
0
90 100
0
10
20
30
Output Load [%]
40
50
60
70
80
90 100
Output Load [%]
REGULATIONS
Parameter
Condition
Value
Output Accuracy
±5.0% max.
Line Regulation
low line to high line, full load
10% to 100% load
Load Regulation (7)
1.2%/1% of Vin typ.
3.3Vout, 5Vout
9Vout, 12Vout, 15Vout
15.0% typ.
10.0% typ.
Notes:
Note7: Operation below 10% load won‘t harm the converter, but specifications may not be met
Deviation vs. Load
RxxP205S/R6.4 and
RxxP205S/R8
30
30
25
5Vin
12Vin
24Vin
20
Deviation [%]
Deviation [%]
25
15
10
5
0
5Vin
12Vin
24Vin
20
15
10
5
0
-5
-10
RxxP205D/R6.4 and
RxxP205D/R8
-5
0
10
20
30
40
50
60
70
80
-10
90 100
Output Load [%]
0
10
20
30
40
50
60
70
80
90 100
Output Load [%]
continued on next page
www.recom-power.com
REV.: 6/2020
ECO-2
RxxP2xx/R
DC/DC Converter
Series
Specifications (measured at Ta= 25°C, nominal input voltage, full load)
Output Voltage [%]
Tolerance Envelope
+10%
+5%
+5%
Typical L
o
ad Line
Vnom
-1.5%
-5%
10
50
100
Load [%]
PROTECTIONS
Parameter
Type
Short Circuit Protection (SCP)
Isolation Voltage (8)
Value
without Suffix “/P”
with Suffix “/P”
tested for 1 second
“/R6.4”
“/R8”
rated for 1 minute
“/R6.4”
“/R8”
I/P to O/P
Isolation Resistance
Isolation Capacitance
1 second
continuous
6.4kVDC
8kVDC
3.2kVAC/60Hz
4kVAC/60Hz
15GΩ min.
1.5pF min./10.0pF max.
Leakage Current
4.8mm
External
clearance/creepage
>4.8mm
Means of Protection
Notes:
Note8: For repeat Hi-Pot testing, reduce the time and/or the test voltage
ENVIRONMENTAL
Parameter
Operating Temperature Range
Condition
Value
without derating @ natural convection 0.1m/s (see graph)
Maximum Case Temperature
+105°C
Operating Altitude
Operating Humidity
-40°C to +85°C
3000m
non-condensing
95% RH max.
Pollution Degree
MTBF
PD2
according to MIL-HDBK-217F, G.B.
+25°C
+85°C
23429 x 10 hours
9818 x 103 hours
3
continued on next page
www.recom-power.com
REV.: 6/2020
ECO-3
RxxP2xxS_D/R
DC/DC Converter
Series
Specifications (measured at Ta= 25°C, nominal input voltage, full load)
Derating Graph
(@ Chamber and natural convection 0.1m/s)
100
90
Output Load [%]
80
70
60
50
40
30
20
10
0
-40 -30 -20 -10 0 10 20 30 40 50 60 70 80 90 100 110
85
Ambient Temperature [°C]
SAFETY AND CERTIFICATIONS
Certificate Type (Safety)
Report / File Number
Information Technology Equipment, General Requirements for Safety
LVD1605077-14
Information Technology Equipment, General Requirements for Safety
2236395
Information Technology Equipment, General Requirements for Safety
2207629
Medical Electric Equipment, General Requirements for Safety and
Essential Performance
Medical Electric Equipment, General Requirements for Safety and
Essential Performance
Medical Electric Equipment, General Requirements for Safety and
Essential Performance. (CB Scheme)
2207629
E314885-A5-UL
E314885-A5-CB-1
Medical Electric Equipment, General Requirements for Safety and
Essential Performance
Safety requirements for electrical equipement for measurement, control
and laboratory use
EAC
WD-SE-R-180539-A0
T1301251-313
RU-AT.37.02367
RoHS 2
EMC Compliance
Electromagnetic compatibility of multimedia equipment Emission requirements
Standard
EN60950-1: 2006 + A2:2013
IEC60950-1-2005 , 2nd Edition + A2:2013
ANSI/UL60950-1, 1st Edition
CAN/CSA-C22.2 No. 60950-1
ANSI/UL60950-1, 1st Edition
CAN/CSA C22.2 No. 60950-1
UL60601-1, 1st Edition
CAN/CSA-C22.2 No. 601.1-M90
ANSI/AAMI ES60601-1:2005 +A2:10
CAN/CSA-C22.2 No. 60601-1:2008
IEC60601-1:2005 + C2:2007
EN60601-1:2006 + A12:2014
IEC60601-1:2005 + A1:2012, 3rd Edition
EN61010:2010
IEC61010:2010, 3rd Edition
TP TC 004/2011
RoHS-2011/65/EU + AM-2015/863
Condition
Standard / Criterion
with external filter
(refer to “EMC Filtering”)
EN55032, Class A and B
continued on next page
www.recom-power.com
REV.: 6/2020
ECO-4
RxxP2xxS_D/R
DC/DC Converter
Series
Specifications (measured at Ta= 25°C, nominal input voltage, full load)
EMC Filtering Suggestion according to EN55032 Class A and Class B
Single Output
Dual Output
C3
+Vin
L1
+Vout
+Vin
C2
C1
-Vin
L1
+Vout
+Vout
+Vout
-Vout
-Vout
-Vout
+Vout
+Vinin
C1
-Vin
C3
L1
+V
+Vin
C2
-Vout
-Vin
+Vin
C3
C2
+Vin
ComC2
C1
-Vout
-V
-Vin
-Vinin
+Vout
Com
-Vin
C1
L1
C3
C1
10µF 100V MLCC
3.9µH choke
WE 744 045 0039
470pF
C2
10µF 100V MLCC 2.2µF 100V MLCC
L1
C3
12µH choke
WE 744 045 120
470pF
DIMENSION AND PHYSICAL CHARACTERISTICS
Parameter
Type
Value
Material
case
potting
PCB
non-conductive black plastic, (UL94 V-0)
silicon rubber compound, (UL94 V-0)
FR4, (UL94 V-0)
Dimension (LxWxH)
19.5 x 9.8 x 12.5mm
Weight
4.3g typ.
Dimension Drawing (mm)
embossed logo
9.8
12.5
19.5
Marking
0.25±0.05
4.10
0.50+0.10/-0.05
Recommended Footprint Details
5
6 7
1 2
2.54
1 2
2.4
Bottom View
3x2.54= 7.62
1.9
Pin Connection
Pin # Single
1
+Vin
2
-Vin
5
-Vout
6
No Pin
7
+Vout
Dual
+Vin
-Vin
-Vout
Com
+Vout
/X2
+Vin
-Vin
No Pin
-Vout
+Vout
Tolerance: xx.x= ±0.5mm
xx.xx= ±0.25mm
5 6 7
Top View
2.54
6x2.54= 15.24
PACKAGING INFORMATION
Parameter
Type
Value
Packaging Dimension (LxWxH)
tube
520.0 x 22.3 x 12.0mm
Packaging Quantity
tube
25pcs
Storage Temperature Range
- 55°C to +125°C
Storage Humidity
95% RH max.
The product information and specifications may be subject to changes even without prior written notice.The product has been designed for various applications; its suitability lies in the responsibility of each customer. The
products are not authorized for use in safety-critical applications without RECOM’s explicit written consent. A safety-critical application is an application where a failure may reasonably be expected to endanger or cause
loss of life, inflict bodily harm or damage property. The applicant shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the unauthorized
use of RECOM products in such safety-critical applications.
www.recom-power.com
REV.: 6/2020
+Vout
Com
-Vout
-Vout
Component List Class B
Component List Class A
0.51
L1
C3
ECO-5