Features
Unregulated
Converters
• Qualified with 65kV/µs @ Vcommon mode =1KV
• EN61010 for test, measurement and lab use
• EN60601 for medical applications
• Reinforced isolation 6.4kVDC or 8kVDC
• Optional continuous short circuit protection
• Unique reinforced isolation transformer system
• /X2 option for >9mm input/output clearance
Description
2200
5, 12, 15, 24
5
200
75 - 80
1000
RxxP09S/R(3,4,5)
5, 12, 15, 24
9
111
75 - 82
1000
5, 12, 15, 24
12
84
75 - 82
470
RxxP15S/R(3,4,5)
5, 12, 15, 24
15
66
75 - 83
470
(3,4,5)
5, 12, 15, 24
±3.3
±151
72 - 79
±1000
RxxP05D/R(3,4,5)
5, 12, 15, 24
±5
±100
75 - 82
±470
(3,4,5)
±220
5, 12, 15, 24
±15
±33
75 - 83
±220
RxxP15D/R
(3,4,5)
O
M
CONVER
T
RoHS 2 +
compliant
M
10 from 10
PL
U
D
IA N
T PRO
C
O
M
CONVER
y
T
REACH
compliant
CO
CO
Notes:
Note1: Efficiency is tested at nominal input and full load at +25°C ambient
Note2: Max. Capacitive Load is defined as the capacitive load that will allow start up
in under 1 second without damage to the converter
C
S
±470
75 - 82
R
75 - 82
±41
E
±55
±12
S
±9
5, 12, 15, 24
R
5, 12, 15, 24
E
RxxP12D/R(3,4,5)
RxxP09D/R
(3,4,5)
M
TS
70 - 80
C
303
RE
3.3
TS
5, 12, 15, 24
(3,4,5)
C
RxxP3.3S/R(3,4,5)
arrant
RE
nom. Input
Output
Output
Efficiency max. Capacitive
Voltage Voltage Current typ. (1) Load (2)
[VDC] [VDC] [mA] [%]
[µF]
RxxP3.3D/R
1 Watt
3
SIP7
Single and Dual
Output
w
Selection Guide
Part
Number
RxxP12S/R
RxxPxx/R
YEA R
The RxxPxxS_D Series of DC/DC Converters are certified to UL/CSA60950-1. This makes them ideal for
safety applications where approved or reinforced isolation is required. The reinforced versions are also
EN61010-1 certified for Lab Equipment Safety.
RxxP05S/R
DC/DC Converter
PL
U
D
IA N
T PRO
E314885
Model Numbering
R__P__ _/P/X2/R
Input Voltage
“Reinforced Isolation (3)”
Output Voltage
“Pinout (4)”
Single or Dual
“Protection (5)”
UL/CSA60950-1 certified
IEC/EN60950-1 certified
UL/ES/CSA60601-1 certified
IEC/EN60601-1 certified
IEC/EN61010-1 certified
CB report
Notes:
Note3: add suffix „/R6.4“ for 6.4kVDC/1second isolation or „/R8“ for 8kVDC/1second isolation
Note4: add suffix „/X2“ for single output with alternative pinout
Note5: add suffix „/P“ for continous short circuit protection
Ordering Examples:
R05P3.3S/R8/P = 5V Input, 3.3V Output, Single Output, 8kVDC/1s isolation, Continous Short Circuit Protection
R24P05S/R6.4/P/X2 = 24V Input, 5V Output, Single Output, 6.4kVDC/1s isolation, Continous SCP, Alternative Pinout
R12P05D/R8/X2 = ±12V Input, ±5V Output, Dual Output, 8kVDC/1s isolation, Alternative Pinout
REF
DESIGN
available
www.recom-power.com/eval-ref-boards
www.recom-power.com
REV.: 6/2020
dv/dt
ADVISORY
REPORT
AVAILABLE
www.recom-power.com/bier
ECO-1
RxxPxx/R
DC/DC Converter
Series
Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated)
BASIC CHARACTERISTICS
Parameter
Condition
Min.
Typ.
Input Voltage Range
Max.
±10%
Minimum Load
Internal Operating Frequency
0%
20kHz
Output Ripple and Noise
50kHz
85kHz
20MHz BW
200mVp-p
Efficiency vs. Load
RxxP05D/R6.4 and RxxP05D/R8
100
100
90
90
80
80
70
70
Efficiency [%]
Efficiency [%]
RxxP05S/R6.4 and RxxP05S/R8
60
50
40
30
50
40
30
20
20
R05P05S
R12P05S
R24P05S
10
0
60
0
10
20
30
40
50
60
70
80
90
R05P05D
R12P05D
R24P05D
10
0
100
0
10
20
Output Load [%]
30
40
50
60
70
80
90
100
Output Load [%]
REGULATIONS
Parameter
Condition
Value
Output Accuracy
±5.0% max.
Line Regulation
low line to high line, full load
10% to 100% load
Load Regulation (6)
1.2%/1% of Vin typ.
3.3Vout, 5Vout
9Vout, 12Vout, 15Vout
15% typ.
10% typ.
Notes:
Note6: Operation below 10% load will not harm the converter, but specifications may not be met
Output Voltage [%]
Tolerance Envelope
+10%
+5%
Typical L
o
ad Line
Vnom
+5%
-1.5%
-5%
10
50
100
Load [%]
continued on next page
www.recom-power.com
REV.: 6/2020
ECO-2
RxxPxx/R
DC/DC Converter
Series
Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated)
Deviation vs. Load
RxxP05D/R6.4 and RxxP09D/R8
25
20
20
15
15
Deviation [%]
Deviation [%]
RxxP05S/R6.4 and RxxP09S/R8
25
10
5
0
-5
-15
0
10
20
30
40
5
0
-5
R05P05S/R6.4
R12P05S/R6.4
R24P05S/R6.4
-10
10
R05P05D/R6.4
R12P05D/R6.4
R24P05D/R6.4
-10
50
60
70
80
90
-15
100
0
10
20
Output Load [%]
30
40
50
60
70
80
90
100
Output Load [%]
PROTECTIONS
Parameter
Type
Short Circuit Protection (SCP)
Isolation Voltage (7)
Value
without Suffix “/P”
with Suffix “/P”
tested for 1 second
“/R6.4”
“/R8”
rated for 1 minute
“/R6.4”
“/R8”
I/P to O/P
Isolation Resistance
Isolation Capacitance
1 second
continuous
6.4kVDC
8kVDC
3.2kVAC/60Hz
4kVAC/60Hz
15GΩ min.
4.0pF min. / 10pF max.
Leakage Current
4.8mm
External
clearance/creepage
>4.8mm
Means of Protection
Notes:
Note7: For repeat Hi-Pot testing, reduce the time and/or the test voltage
ENVIRONMENTAL
Parameter
Operating Temperature Range
Condition
Value
without derating @ free air convection (see graph)
Maximum Case Temperature
+105°C
Operating Altitude
Operating Humidity
-40°C to +85°C
3000m
non-condensing
95% RH max.
Pollution Degree
MTBF
PD2
according to MIL-HDBK-217F, G.B.
+25°C
+85°C
2974 x 10 hours
728 x 103 hours
3
continued on next page
www.recom-power.com
REV.: 6/2020
ECO-3
RxxPxx/R
DC/DC Converter
Series
Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated)
Derating Graph
(@ Chamber and free air convection)
100
90
Output Load [%]
80
70
60
50
40
30
20
10
0
-40 -30 -20 -10 0 10 20 30 40 50 60 70 80 90 100 110
85
Ambient Temperature [°C]
SAFETY AND CERTIFICATIONS
Certificate Type (Safety)
Report / File Number
Information Technology Equipment, General Requirements for Safety
LVD1605077-14
Standard
EN60950-1: 2006 + A2:2013
IEC60950-1-2005 , 2nd Edition + A2:2013
Information Technology Equipment, General Requirements for Safety
2236395
ANSI/UL60950-1, 1st Edition
CAN/CSA-C22.2 No. 60950-1
Information Technology Equipment, General Requirements for Safety
2207629
ANSI/UL60950-1, 1st Edition
CAN/CSA C22.2 No. 60950-1
Medical Electric Equipment, General Requirements for Safety and
Essential Performance
Medical Electric Equipment, General Requirements for Safety and
Essential Performance
Medical Electric Equipment, General Requirements for Safety and
Essential Performance. (CB Scheme)
2207629
E314885-A5-UL
E314885-A5-CB-1
Medical Electric Equipment, General Requirements for Safety and
Essential Performance
Safety requirements for electrical equipement for measurement, control
and laboratory use
EAC
WD-SE-R-180539-A0
T1301251-313
RU-AT.37.02367
RoHS 2
EMC Compliance
Electromagnetic compatibility of multimedia equipment Emission requirements
UL60601-1, 1st Edition
CAN/CSA-C22.2 No. 601.1-M90
ANSI/AAMI ES60601-1:2005 + A2:10
CAN/CSA-C22.2 No. 60601-1:2008
IEC60601-1:2005 + C2:2007
EN60601-1:2006 + A12:2014
IEC60601-1:2005 + A1:2012, 3rd Edition
EN61010:2010
IEC61010:2010, 3rd Edition
TP TC 004/2011
RoHS-2011/65/EU + AM-2015/863
Condition
Standard / Criterion
with external filter
(refer to „EMC Filtering“)
EN55032, Class A and B
continued on next page
www.recom-power.com
REV.: 6/2020
ECO-4
RxxPxx/R
DC/DC Converter
Series
Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated)
EMC Filtering Suggestion according to EN55032 Class A and Class B
Class A
+Vin
C2
+Vin
+Vin
C1
-Vin
Class B
C2
+Vout
+Vin
+Vout
+Vout
C3
L1
+Vout
+Vin
C1
C1
-Vin
-Vin
-Vout
-Vin
-Vout
-Vout
-Vout
-Vin
Component List Class A
L1
+Vin
+Vin
C2
C1
+Vin
+Vout
+Vout
+Vout
-Vin
-Vout
-Vout
-Vout
+Vout
C2
-Vin
-Vin
C3
-Vout
Component List Class B
Model
C1
C2
Model
C1
L1
C2
C3
RxxPxx/R6.4
10µF
2n2F 8kV
RxxPxx/R6.4
10µF
470µH
WE 7447471471
10µF
2n2F 8kV
RxxPxx/R8
10µF
2n5F 10kV
RxxPxx/R8
10µF
470µH
WE 7447471471
10µF
2n5F 10kV
DIMENSION AND PHYSICAL CHARACTERISTICS
Parameter
Type
Value
Material
case
potting
PCB
non-conductive black plastic, (UL94 V-0)
silicon rubber compound, (UL94 V-0)
FR4, (UL94 V-0)
Dimension (LxWxH)
19.5 x 9.8 x 12.5mm
Weight
4.3g typ.
Dimension Drawing (mm)
embossed logo
9.8
Pin Connection
Pin # Single
1
+Vin
2
-Vin
5
-Vout
6
No Pin
7
+Vout
Marking
0.51
12.5
19.5
Dual
+Vin
-Vin
-Vout
Com
+Vout
/X2
+Vin
-Vin
No Pin
-Vout
+Vout
Tolerance: xx.x= ±0.5mm
xx.xx= ±0.25mm
0.25±0.05
4.10
0.50+0.10/-0.05
Recommended Footprint Details
3x2.54= 7.62
1.9
6 7
2.54
5
1 2
2.4
Bottom View
1 2
5 6 7
Top View
2.54
6x2.54= 15.24
www.recom-power.com
REV.: 6/2020
ECO-5
RxxPxx/R
DC/DC Converter
Series
Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated)
PACKAGING INFORMATION
Parameter
Type
Value
Packaging Dimension (LxWxH)
tube
520.0 x 22.3 x 12.0mm
Packaging Quantity
tube
25pcs
Storage Temperature Range
-55°C to +125°C
Storage Humidity
95% RH max.
The product information and specifications may be subject to changes even without prior written notice.The product has been designed for various applications; its suitability lies in the responsibility of each customer. The
products are not authorized for use in safety-critical applications without RECOM’s explicit written consent. A safety-critical application is an application where a failure may reasonably be expected to endanger or cause
loss of life, inflict bodily harm or damage property. The applicant shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the unauthorized
use of RECOM products in such safety-critical applications.
www.recom-power.com
REV.: 6/2020
ECO-6