Features
• 35mW max. no load power consumption
• Efficiency up to 76%
• Isolated output 3kVAC / 1 min
• SCP, OVP protection
• Wide operating temperature range: -40°C to +85°C
• Universal input 85-305VAC
Regulated
Converter
Description
The ultra-compact RAC02-SE/277 modules are available with output voltages of 3.3, 5, 12 and
24V, and the input-to-output isolation is 3kVAC/1min. With a standby consumption of 35mW
maximum, the mini power supplies are particularly suitable for energy-saving sleep mode and
standby applications. Because of its compact design (height 95%
Voltage Dips 30%
Voltage Interruptions >95%
EN61000-4-8:2010, Criteria A
EN61000-4-11:2004, Criteria A
EN61000-4-11:2004, Criteria A
EN61000-4-11:2004, Criteria B
EN61000-3-3:2013
Limits of Voltage Fluctuations & Flicker
EMC Compliance (Household)
Condition
Electromagnetic compatibility - Requirements for household appliances, electric
tools and similar apparatus - Part 1: Emission
EN55014-1:2006+A2:2011
Information technology equipment - Immunity characteristics - Limits and methods
of measurement
ESD Electrostatic discharge immunity test
Radiated, radio-frequency, electromagnetic field immunity test
EN55014-2:2015
±8kV air, ±4kV contact
3V/m
AC Power Port: ±1kV
DC Output: ±0.5kV
Fast Transient and Burst Immunity
Standard / Criterion
IEC61000-4-2:2008, Criteria A
IEC61000-4-3:2006 + A2:2010, Criteria A
IEC61000-4-4:2012, Criteria A
continued on next page
www.recom-power.com
REV.: 10/2018
PA-4
RAC02-SE/277
AC/DC Converter
Series
Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated)
SAFETY AND CERTIFICATIONS
EMC Compliance (Household)
Condition
Standard / Criterion
AC Power Port:L to N ±2kV
DC Output: L to N ±1kV
Surge Immunity
Immunity to conducted disturbances, induced by radio-frequency fields
3 Vr.m.s.
Voltage Dips >95%
Voltage Dips 30%
Voltage Interruptions >95%
Voltage Dips and Interruptions
Limits of Harmonic Current Emissions
Limits of Voltage Fluctuations & Flicker
IEC61000-4-5:2014, Criteria B
IEC61000-4-6:2013, Criteria A
IEC61000-4-11:2004, Criteria B
IEC61000-4-11:2004, Criteria C
IEC61000-4-11:2004, Criteria C
EN61000-3-2:2014
EN61000-3-3:2013
DIMENSION AND PHYSICAL CHARACTERISTICS
Parameter
Type
Value
Material
case
potting
black plastic, (UL94V-0)
silicone, (UL94V-0)
Dimension (LxWxH)
33.70 x 22.20 x 17.75mm
Weight
24.5g typ.
Dimension Drawing (mm)
embossed logo
22.2
6.1
0.75 ±0.25
17.75 ±0.25
33.7
5.0
Ø 0.8±0.1
Recommended Footprint Details
28.0
7.0
3
7.62
4
Top View
2.54
tc
15.24
Bottom View
18.0
1
3
1
2
Pin Connections
Pin #
Single
1
VAC in (N)
2
VAC in (L)
3
-Vout
4
+Vout
Tolerance: xx.x= ±0.5mm
xx.xx= ±0.35mm
Pin width: ±0.05mm
4
2
2.54
PACKAGING INFORMATION
Parameter
Type
Value
Packaging Dimension (LxWxH)
tube
520.0 x 37.0 x 28.0mm
Packaging Quantity
22pcs
Storage Temperature Range
-40°C to +85°C
The product information and specifications may be subject to changes even without prior written notice.The product has been designed for various applications; its suitability lies in the responsibility of each customer. The
products are not authorized for use in safety-critical applications without RECOM’s explicit written consent. A safety-critical application is an application where a failure may reasonably be expected to endanger or cause
loss of life, inflict bodily harm or damage property. The applicant shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the unauthorized
use of RECOM products in such safety-critical applications.
www.recom-power.com
REV.: 10/2018
PA-5
很抱歉,暂时无法提供与“RAC02-05SE/277”相匹配的价格&库存,您可以联系我们找货
免费人工找货- 国内价格
- 1+167.15994
- 22+149.22082
- 66+147.18229
- 110+144.00217