Features
• Universal input 85-264VAC
• 95%
EN61000-4-11:2004, Criteria A
Voltage Dips 30%
EN61000-4-11:2004, Criteria B
Voltage Interruptions >95%
EN61000-4-11:2004, Criteria B
Limits of Voltage Fluctuations & Flicker
EN61000-3-3:2013
DIMENSION AND PHYSICAL CHARACTERISTICS
Parameter
Type
Value
Material
case
PCB
black plastic (UL94V-2)
FR4 (UL94V-0)
Dimension (LxWxH)
33.7 x 22.2 x 19.0mm
Weight
12g typ.
Dimension Drawing (mm)
Pin Connections
Pin #
Single
1
VAC in (L)
2
VAC in (N)
3
-Vout
4
+Vout
19.0
embossed logo
22.2
33.7
Tolerance:
Pin length: -0.5/+0.9
xx.x= ±0.5mm
x.xx= ±0.25mm
15.24
3.7
2.85
Recommended Footprint Details
2.54
Ø0.8±0.03
2
Bottom View
2
4
3
3
2.54
7.62
1
Top View
4
1
28.00
www.recom-power.com
REV.: 3/2019
PA-5
RAC02-GB
AC/DC Converter
Series
Specifications (measured @ Ta= 25°C, nom. Vin (115/230VAC), full load and after warm-up unless otherwise stated)
PACKAGING INFORMATION
Parameter
Type
Value
Packaging Dimension (LxWxH)
tube
470.0 x 36.4 x 26.4mm
Packaging Quantity
20pcs
Storage Temperature Range
Storage Humidity
-25°C to +85°C
non-condensing
5% - 95% RH max.
The product information and specifications may be subject to changes even without prior written notice.The product has been designed for various applications; its suitability lies in the responsibility of each customer. The
products are not authorized for use in safety-critical applications without RECOM’s explicit written consent. A safety-critical application is an application where a failure may reasonably be expected to endanger or cause
loss of life, inflict bodily harm or damage property. The applicant shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the unauthorized
use of RECOM products in such safety-critical applications.
www.recom-power.com
REV.: 3/2019