!NOT RECOMMENDED FOR NEW DESIGNS!
• 50mW max. no load power consumption
Features
• High efficiency up to 79%
Regulated
Converter
Description
RAC
RAC04-C/277
4 Watt
Single and
Dual Output
YEA R
3
arrant
w
The RAC04-xxS_DC/277 series are fully certified single and dual regulated AC/DC converters in an encapsulated
PCB-mount package style with 3.75kVAC isolation and very low stand-by power consumption. The modules are
suitable for worldwide use due to their wide input voltage range from 80VAC to 305VAC. Possible uses include
home automation, standby applications and industrial controls.
AC/DC Converter
y
• Isolated Output 3.75kVAC / 1 minute
• SCP, OVP protection
• Wide operating temperature range
-40°C to +80°C (only with suffix „-E“)
• Universal input 80-305VAC
T
CONVER
T
REACH
compliant
M
ERP
compliant
TS
TS
C
M
S
PL
U
D
IA N
T PRO
CO
CO
10 from 10
M
O
R
S
RoHS 2 +
compliant
C
C
CONVER
RE
M
E
O
R
C
E
RE
Selection Guide
Part
Input
Output
Output
Efficiency Max. Capacitive
Number
Voltage Range
Voltage
Current
typ.
Load (1,2)
[(VAC] [VDC] [mA] [%] [µF)
RAC04-3.3SC/277(3) 80-305 3.3 1200 72 10000
RAC04-05SC/277 (3) 80-305 5 800 75 7200
RAC04-12SC/277 (3) 80-305 12 333 78 1000
RAC04-15SC/277 (3) 80-305 15 267 79
820
RAC04-24SC/277 (3) 80-305 24 167 79
220
RAC04-0512DC/277 (3) 80-305 5/12 720/33 75
4700/100
RAC04-05DC/277 (3) 80-305 ±5 ±400 76 ±3300
RAC04-12DC/277 (3) 80-305 ±12 ±166 78 ±680
PL
U
D
IA N
T PRO
E224736
Notes:
Note1: Measured @ 230VAC/50Hz/Ta 25°C with constant resistant mode at full load
Note2: If used @115VAC/60Hz with full load, max. capacitive load is less, please contact
RECOM Tech Support for detailed information
PREFERRED ALTERNATIVES
Please consider these alternatives:
Model Numbering
RAC04-K/277 Series
RAC04-__ _C/277 -_
Output Voltage
Temperature (3)
Single or Dual
Ordering Examples:
e.g. RAC04-3.3SC/277-E, Single Output, with -40° to +80°C operating temperature range
e.g. RAC04-05DC/277, Dual Output with standard operating temperature range
RAC10-K/277 Series
IEC/EN60950-1 certified
IEC/EN62368-1 certified
UL60950-1 certified
CSA/CAN 22.2 60950-1-07 certified
CB Report
EN55032 compliance
EN55024 compliance
Notes:
Note3: with suffix “-E” for -40°C to +80°C operating temperature range
without suffix standard operating temperature range (-25°C to +80°C)
www.recom-power.com
REV.: 7/2020
PA-1
! NOT RECOMMENDED FOR NEW DESIGNS !
RAC04-C/277
AC/DC Converter
Series
Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated)
BASIC CHARACTERISTICS
Parameter
Condition
Input Voltage Range (4)
Min.
Typ.
Max.
80VAC
113VDC
277VAC
390VDC
305VAC
430VDC
115VAC
230VAC
Input Current
Inrush Current
115VAC
230VAC
cold start at +25°C
No load Power Consumption
98mA
64mA
15A
30A
80-305VAC, 50/60Hz
Input Frequency Range
50mW
AC input
47Hz
440Hz
RAC04-0512DC/277(-E)
all others
Minimum Load
Hold-up time
115VAC
Internal Operating Frequency
full load
Output Ripple and Noise
±5% / ±0%
0%
15ms
67kHz
200mVp-p
(5)
Notes:
Note4:
Note5:
Refer to line derating graph on page PA-5
Ripple and Noise is measured at 20MHz bandwidth and with a 47µF low-ESR electrolytic capacitor in parallel with a 0.1µF ceramic
capacitor across output
RAC04-3.3SC/277 (-E)
RAC04-05SC/277 (-E)
100
100
90
90
80
80
70
70
Efficiency [%]
Efficiency [%]
Efficiency vs. Load
60
50
40
30
115VAC
230VAC
277VAC
10
40
0
10
20
30
40
50
60
70
80
90
10
0
100
0
10
20
30
40
50
60
70
Output Load [%]
Output Load [%]
RAC04-12SC/277 (-E)
RAC04-15SC/277 (-E)
100
100
90
90
80
80
70
70
60
50
40
30
80
90
100
60
50
40
30
115VAC
230VAC
277VAC
20
10
0
115VAC
230VAC
277VAC
20
Efficiency [%]
Efficiency [%]
50
30
20
0
60
0
10
20
30
40
50
60
Output Load [%]
www.recom-power.com
70
80
90
115VAC
230VAC
277VAC
20
10
100
continued on next page
REV.: 7/2020
0
0
10
20
30
40
50
60
70
80
90
100
Output Load [%]
PA-2
! NOT RECOMMENDED FOR NEW DESIGNS !
RAC04-C/277
AC/DC Converter
Series
Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated)
RAC04-05DC/277 (-E)
100
90
90
80
80
70
70
Efficiency [%]
Efficiency [%]
RAC04-24SC/277 (-E)
100
60
50
40
60
50
40
30
30
115VAC
230VAC
277VAC
20
10
0
0
10
20
30
40
50
60
70
80
90
115VAC
230VAC
277VAC
20
10
0
100
0
10
20
30
Output Load [%]
50
60
70
80
90
100
RAC04-15DC/277 (-E)
100
90
90
80
80
70
70
Efficiency [%]
Efficiency [%]
RAC04-12DC/277 (-E)
100
60
50
40
30
60
50
40
30
115VAC
230VAC
277VAC
20
10
0
40
Output Load [%]
0
10
20
30
40
50
60
70
80
90
115VAC
230VAC
277VAC
20
10
0
100
0
10
Output Load [%]
20
30
40
50
60
70
80
90
100
Output Load [%]
REGULATIONS
Parameter
Output Accuracy
Line Regulation
Load Regulation
(5V minimum load 5% @12V full load)v
Condition
single and dual
5V/12V dual assymetrical
90-264VAC
10% to 100% load
single and dual
5V/12V dual assymetrical
3.3V, 5V output
all others
5V/12V dual assymetrical
Value
±2.0% typ.
±2.0% / ±10.0% typ.
±0.2% typ.
±0.2% / ±1.0% typ.
1.0% typ.
0.5% typ.
1.0% / 5.0% typ.
PROTECTIONS
Parameter
Type
Value
Short Circuit Protection (SCP)
automatic recovery
Over Voltage Category
Isolation Voltage
Isolation Resistance
OVC II
I/P to O/P
tested for 1 minute
Insulation Grade
Leakage Current
3.75kVAC
100MΩ min.
reinforced
277VAC / 50Hz
0.25mA max.
continued on next page
www.recom-power.com
REV.: 7/2020
PA-3
! NOT RECOMMENDED FOR NEW DESIGNS !
RAC04-C/277
AC/DC Converter
Series
Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated)
Notes:
Note6: Refer to local safety regulations if input over-current protection is also required
Note7: To measure the output ripple and noise short runs by 0.1µF/50V & 47µF/50V @20MHz, nominal input and full load
Note8: An external MOV is required for 230VAC operation. (MOV model: shall comply with IEC 61051-2) e.g. Epcos S14 Series
Protection Circuit
VACin (L)
FUSE
+Vout
0.1µF/50V
MOV
47µF/50V
VACin (N)
-Vout
ENVIRONMENTAL
Parameter
Condition
Value
230VAC
Operating Temperature Range
@ natural convection 0.1m/s
with suffix “-E”
full load
-25°C to +65°C
refer to derating graph
-25°C to +80°C
full load
-40°C to +65°C
refer to derating graph
-40°C to +80°C
+90°C
Maximum Case Temperature
Thermal Impedance
10°C/W
Operating Altitude
2000m
Operating Humidity
non-condensing
95%, RH max.
Pollution Degree
PD2
Vibration
MIL-STD-202G
MTBF
according to MIL-HDBK-217F, G.B
500 x 103 hours
+25°C
Derating Graph
(@ Chamber and natural convection 0.1m/s)
RAC04-xxS(D)C/277-E
100
100
90
90
80
80
70
70
Output Load [%]
Output Load [%]
RAC04-xxS(D)C/277
60
50
40
60
50
40
30
30
20
20
10
10
0
-25 -20
0
20
40
60 65
0
-40
80 90
Ambient Temperature [°C]
-20
0
20
40
60 65
80 90
Ambient Temperature [°C]
continued on next page
www.recom-power.com
REV.: 7/2020
PA-4
! NOT RECOMMENDED FOR NEW DESIGNS !
RAC04-C/277
AC/DC Converter
Series
Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated)
Line Derating
100
90
Output Load [%]
80
70
60
50
40
30
20
10
0
80
305
Input Voltage [VAC]
SAFETY AND CERTIFICATIONS
Certificate Type
Report / File Number
Standard
Information Technology Equipment, General Requirements for Safety (CB Scheme)
1310055-1-CB-M1
IEC60950-1:2005, 2nd Edition + A1:2009
Information Technology Equipment, General Requirements for Safety (LVD)
SPCLVD1605077-04
EN60950-1:2006 + A2:2013
IEC60950-1:2005 2nd Edition + A2:2013
Information Technology Equipment, General Requirements for Safety
E224736-A18
Audio/video, information and communication technology equipment - Safety
requirements
AL106051
EAC
RU-AT.03.67361
RoHS2+
UL No. 60950-1, 2nd Edition, 2011
CAN/CSA C22.2 No. 60950-1-07, 2nd Edition, 2011
EN62368-1:2014
IEC62368-1:2014 2nd Edition
TP TC 004/020, 2011
RoHs-2011/65/EU + AM-2015/863
EMC Compliance
Report / File Number
Electromagnetic compatibility of multimedia equipment - Emission requirements
EN55032, Class B
T160225D10-E
Information technology equipment - Immunity characteristics - Limits and
methods of measurement
Air: ±2, 4, 8kV
Contact: ±4kV
ESD Electrostatic discharge immunity test
Radiated, radio-frequency, electromagnetic field immunity test
3V/m
Fast Transient and Burst Immunity
AC Power Port: ±1kV
Surge Immunity
Standard / Criterion
EN55024:2010
IEC61000-4-2:2008, Criteria A
IEC61000-4-3:2010, Criteria A
IEC61000-4-4:2004 + A1:2010, Criteria A
AC Power Port: L-N ±1kV
IEC61000-4-5:2005, Criteria A
AC Power Port: 3V
IEC61000-4-6:2008, Criteria A
Immunity to conducted disturbances, induced by radio-frequency fields
Power Magnetic Field Immunity
50Hz, 1A/m
IEC61000-4-8:2009, Criteria A
Voltage Dips and Interruptions
Voltage Dips: >95%
Voltage Dips: 30%
Interruptions: >95%
IEC61000-4-11:2004, Criteria A
IEC61000-4-11:2004, Criteria A
IEC61000-4-11:2004, Criteria B
DIMENSION and PHYSICAL CHARACTERISTICS
Parameter
Type
Value
Material
case
potting
PCB
black plastic (UL94 V-0)
silicone (UL94 V-0)
FR4 (UL94 V-0)
Dimension (LxWxH)
36.7 x 27.2 x 17.1mm
Weight
41g typ.
continued on next page
www.recom-power.com
REV.: 7/2020
PA-5
! NOT RECOMMENDED FOR NEW DESIGNS !
RAC04-C/277
AC/DC Converter
Series
Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated)
Dimension Drawing (mm)
36.7
Pinning information
Pin #
1
2
3
4
5
6
7
27.2
embossed logo
36.0
17.1
26.5
Dual
Dual (assymetric)
No Pin
No Pin
+Vout
+5Vout
Com
Com
-Vout
+12Vout
VAC in (L)
VAC in (L)
VAC in (N)
VAC in (N)
NC*
NC*
*Pin 7 is NC but need 4mm minimum clearence to ground for safety
NC= no connection
Tolerance: xx.x= ±0.5mm
xx.xx= ±0.25mm
21.0
4.0
Ø0.6±0.05
Single
No Pin
+Vout
-Vout
NC
VAC in (L)
VAC in (N)
NC*
Redommended footprint details
21.5
7
7.5
Bottom View 6
Ø0.9±0.1
restricted area
for PCB layout
2.54
2 3 4
1
5
21.0
2.54
3.1
3.8
Top View
restricted area
for PCB layout
1
2
3.75
7
3 4
6
5
3.75
PACKAGING INFORMATION
Parameter
Type
Value
Packaging Dimension (LxWxH)
tube
520.0 x 32.0 x 27.0mm
Packaging Quantity
12pcs
Storage Temperature Range
-40°C to +100°C
The product information and specifications may be subject to changes even without prior written notice.The product has been designed for various applications; its suitability lies in the responsibility of each customer. The
products are not authorized for use in safety-critical applications without RECOM’s explicit written consent. A safety-critical application is an application where a failure may reasonably be expected to endanger or cause
loss of life, inflict bodily harm or damage property. The applicant shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the unauthorized
use of RECOM products in such safety-critical applications.
www.recom-power.com
REV.: 7/2020
PA-6