!NOT RECOMMENDED FOR NEW DESIGNS!
LAST TIME BUY: 30TH OCT 2020, 3.3SC, 09SC, 05DC
LAST TIME BUY: 27TH NOV 2020, WIRED VERSION
Regulated
Converters
• Universal input 80-264VAC
• High efficiency up to 77%
• Isolated output 3kVAC/1 minute
• Short circuit protection
• Meet EN55032 class B
• Low standby power consumption
Description
RAC05-C
5 Watt
Single &
Dual Output
YEA R
3
arrant
w
Compact, low cost, high efficiency, universal input switching AC/DC power module for PCB or wired
mounting with single or dual outputs. CE/EAC marked and UL/cUL certified.
AC/DC Converter
y
Features
Selection Guide
T
Part
Input
Output
Output
Efficiency
Max. Capacitive
Number
Voltage Range
Voltage
Current
typ (1) Load (2,3)
[VAC] [VDC] [mA] [%]
[µF]
RAC05-3.3SC (4) 80-264 3.3 1250 70
12000
RAC05-09SC (4) 80-264 9 556 75
2500
RAC05-05DC (4) 80-264 ±5 ±500 73 ±3000
Notes:
Note1: Efficiency is tested at nominal input and full load at +25°C ambient
Note2: Measured @ 230VAC / 50Hz / Ta=25°C with constant resistant mode at full load
Note3:
If used @ 115VAC / 60Hz with full load, max. capacitive load is less, please contact
RECOM Techsupport for detailed information
T
U
M
ERP
compliant
TS
TS
compliant
C
D
IA N
T PRO
CO NVE R
S
NRND (Last time buy: 30 Oct 2020)
PL
CO
CO
10 from 10
M
M
REACH
compliant
th
O
R
S
RoHS 2 +
C
P
C
C O N V ER
RE
M
E
O
R
C
E
RE
Part
Input
Output
Output
Efficiency
Max. Capacitive
Number
Voltage Range
Voltage
Current
typ (1) Load (2,3)
[VAC] [VDC] [mA] [%]
[µF]
RAC05-05SC (4) 80-264 5 1000 73
6800
RAC05-12SC (4) 80-264 12 420 76
1500
RAC05-15SC (4) 80-264 15 340 76
750
RAC05-24SC (4) 80-264 24 210 77
330
RAC05-12DC (4) 80-264 ±12 ±210 76
±560
RAC05-15DC (4) 80-264 ±15 ±170 76
±220
U
LIA
D
N T PRO
E224736
UL60950-1 certified
CAN/CSA-C22.2 No. 60950-1 certified
IEC/EN60950-1 certified
EN55032 compliant
EN55024 compliant
PREFERRED ALTERNATIVES
Please consider these alternatives:
Model Numbering
RAC05-K/277/W Series
RAC05-__ _C/W
nom. Output Power
Wired option (4)
nom. Output Voltage
Single or Dual
RAC10-K/277 Series
Notes:
Note4: add suffix „/W“ for wired version
without suffix, standard THT version
Ordering Examples:
RAC05-05SC 5 Watt
RAC05-05SC/W 5 Watt
RAC05-12DC 12 Watt
RAC05-12DC/W 12 Watt
www.recom-power.com
5Vout Single Output THT version
5Vout Single Output wired version
5Vout Dual Output THT version
5Vout Dual Output wired version
REV.: 3/2020
PA-1
! NOT RECOMMENDED FOR NEW DESIGNS !
LAST TIME BUY: 30TH OCT 2020, 3.3SC, 09SC, 05DC & 27TH NOV 2020, WIRED VERSIONS
RAC05-C
Series
AC/DC Converter
Specifications (measured at Ta= 25°C, full load otherwise noted)
BASIC CHARACTERISTICS
Parameter
Input Voltage Range (5)
Condition
Min.
nom. Vin = 230VAC
80VAC
115VDC
Typ.
115VAC
230VAC
Input Current
Inrush Current
Max.
264VAC
370VDC
110mA
70mA
115VAC
230VAC
400 x 10 hours
>200 x 103 hours
+25°C
+55°C
according to MIL-HDBK-217F, G.B.
3
Line Derating
100
100
90
90
80
80
70
70
Output Load [%]
Output Load [%]
(@Chamber and natural convection 0.1m/s)
60
50
40
60
50
40
30
30
20
20
10
10
0
-25
-10
5
20
35
50
65
80
55
70 75
95
110
Ambient Temperature [°C]
www.recom-power.com
0
80
90
264
Input Voltage [VAC]
REV.: 3/2020
PA-3
! NOT RECOMMENDED FOR NEW DESIGNS !
LAST TIME BUY: 30TH OCT 2020, 3.3SC, 09SC, 05DC & 27TH NOV 2020, WIRED VERSIONS
RAC05-C
Series
AC/DC Converter
Specifications (measured at Ta= 25°C, full load otherwise noted)
SAFETY AND CERTIFICATIONS
Certificate Type (Safety)
Report / File Number
Information Technology Equipment - General Requirments for Safety
E224736-A1-UL
Information Technology Equipment - General Requirments for Safety
SPCLVD1605077-06
EAC Safety of Low Voltage Equipment
RU-AT.AB37.B.02367
RoHS2+
Standard
UL60950-1, 2nd Edition, 2007
CAN/CSA-C22.2 No. 60950-1-07, 2nd Edition, 2007
IEC60950-1:2005 2nd Edition + A2:2013
EN60950-1:2006 + A2:2013
TP TC 004/2011
RoHS-2011/65/EU + AM-2015/863
EMC Compliance
Condition
Electromagnetic compatibility of multimedia equipment – Emission Requirements
EN55032:2015
Information technology equipment - Immunity characteristics - Limits and
methods of measurement
ESD Electrostatic discharge immunity test
EN55024:2010 + A1:2015
Air ±8.0kV, Contact ±4.0kV
IEC61000-4-2:2008, Criteria A
3V/m
IEC61000-4-3:2008, Criteria A
Radiated, radio-frequency, electromagnetic field immunity test
Fast Transient and Burst Immunity
Surge Immunity
Immunity to conducted disturbances, induced by radio-frequency fields
Standard / Criterion
AC Power Port: ±1.0kV
IEC61000-4-4:2004, Criteria A
AC Power Port: L-N ±1.0kV
IEC61000-4-5:2005, Criteria A
AC Power Port 3.0V
IEC61000-4-6:2008, Criteria A
Power Magnetic Field Immunity
50Hz, 1A/m
Voltage Dips and Interruptions
Voltage Dips >95%
Voltage Dips 30%
Voltage Interruptions > 95%
IEC61000-4-8:2009, Criteria A
IEC61000-4-11:2004, Criteria A
IEC61000-4-11:2004, Criteria A
IEC61000-4-11:2004, Criteria B
Limits of Harmonic Current Emissions
EN61000-3-2:2014, Class A
Limits of Voltage Fluctuations & Flicker
EN61000-3-3:2013
DIMENSION AND PHYSICAL CHARACTERISTICS
Parameter
Type
Value
Material
case
potting
black plastic (UL94V-0)
epoxy (UL94V-0)
Dimension (LxWxH)
single
dual
50.9 x 25.5 x 16.4mm
53.5 x 27.8 x 16.4mm
Weight
THT version
wired version
35g typ.
38g typ.
continued on next page
www.recom-power.com
REV.: 3/2020
PA-4
! NOT RECOMMENDED FOR NEW DESIGNS !
LAST TIME BUY: 30TH OCT 2020, 3.3SC, 09SC, 05DC & 27TH NOV 2020, WIRED VERSIONS
RAC05-C
Series
AC/DC Converter
Specifications (measured at Ta= 25°C, full load otherwise noted)
Dimension Drawing Single (mm)
embossed logo
Pin Connections
Pin #
Single
1
VAC in (N)
2
VAC in (L)
3
+VDC out
4
-VDC out
5
no pin
25.5
6.1
0.75
16.4
50.9
5.0
Ø1.0±0.1
tc= case temperature measuring point
Tolerance: xx.x= ±0.5mm
xx.xx= ±0.25mm
Recommended Footprint Details
restricted area
for PCB layout
Bottom View
5.0
2.54
1
12.75
tc
3
4
1
Top View
4
10.16
8.0
2
2.54
3
2
45.72
Dimension Drawing Dual (mm)
embossed logo
27.8
6.1
0.75
16.4
53.5
Pin Connections
Pin #
Dual
1
VAC in (N)
2
VAC in (L)
3
+VDC out
4
Com
5
-VDC out
tc= case temperature measuring point
Tolerance: xx.x= ±0.5mm
xx.xx= ±0.25mm
5.0
Ø1.0±1.0
Recommended Footprint Details
1
3
10.16
4
1
Top View
20.32
tc
5.0
10.16
13.90
Bottom View
3
8.0
5
2
2.54
2.54
restricted area
for PCB layout
2
4
5
45.72
continued on next page
www.recom-power.com
REV.: 3/2020
PA-5
! NOT RECOMMENDED FOR NEW DESIGNS !
LAST TIME BUY: 30TH OCT 2020, 3.3SC, 09SC, 05DC & 27TH NOV 2020, WIRED VERSIONS
RAC05-C
Series
AC/DC Converter
Specifications (measured at Ta= 25°C, full load otherwise noted)
Dimension Drawing Single wired (mm)
embossed logo
25.5
0.75
16.4
50.9
88.0
5.0
Wired information
10.0
#
1
2
3
4
Ø2.40
8.0
Ø1.60
L brown
tc
Ø0.76
Ø0.76
5.0
- black
Bottom View
N blue
Function
VAC in (N)
VAC in (L)
+VDC out
-VDC out
Wire color
blue
bown
red
black
Type
UL-1015
UL-1015
UL-1007
UL-1007
AWG
22
22
22
22
Type
UL-1015
UL-1015
UL-1007
UL-1007
UL-1007
AWG
22
22
22
22
22
tc= case temperature measuring point
Tolerance: xx.x= ±0.5mm
xx.xx= ±0.25mm
+ red
Dimension Drawing Dual wired (mm)
embossed logo
27.8
0.75
16.4
53.5
88.0
Wired information
10.0
#
1
2
3
4
5
Ø2.40
Ø1.60
5.0
Ø0.76
8.0
- Orange
L Brown
tc 5.0
Bottom View
N Blue
www.recom-power.com
Com Black
Function
VAC in (N)
VAC in (L)
+VDC out
Com
-VDC out
Wire color
blue
bown
red
black
orange
tc= case temperature measuring point
Tolerance: xx.x= ±0.5mm
xx.xx= ±0.25mm
+ Red
REV.: 3/2020
PA-6
! NOT RECOMMENDED FOR NEW DESIGNS !
LAST TIME BUY: 30TH OCT 2020, 3.3SC, 09SC, 05DC & 27TH NOV 2020, WIRED VERSIONS
RAC05-C
Series
AC/DC Converter
Specifications (measured at Ta= 25°C, full load otherwise noted)
PACKAGING INFORMATION
Parameter
Packaging Dimension (LxWxH)
Packaging Quantity
Type
tube
cardbox
THT
wired
THT single
THT dual
wired
Storage Temperature Range
Storage Humidity
Value
520.0 x 56.0 x 26.0
520.0 x 195.0 x 67.0
10pcs
9pcs
20pcs
-40°C to +100°C
non-condensing
95% RH max.
The product information and specifications may be subject to changes even without prior written notice.The product has been designed for various applications; its suitability lies in the responsibility of each customer. The
products are not authorized for use in safety-critical applications without RECOM’s explicit written consent. A safety-critical application is an application where a failure may reasonably be expected to endanger or cause
loss of life, inflict bodily harm or damage property. The applicant shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the unauthorized
use of RECOM products in such safety-critical applications.
www.recom-power.com
REV.: 3/2020
PA-7